Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beams & optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of secondary ions on the electron beam optics in the Recycler Electron Cooler

Antiprotons in Fermilab's Recycler ring are cooled by a 4.3 MeV, 0.1-0.5 A DC electron beam (as well as by a stochastic cooling system). The unique combination of the relativistic energy ({gamma} = 9.49), an Ampere-range DC beam, and a relatively weak focusing makes the cooling efficiency particularly sensitive to ion neutralization. A capability to clear ions was recently implemented by way of interrupting the electron beam for 1-30 {micro}s with a repetition rate of up to 40 Hz. The cooling properties of the electron beam were analyzed with drag rate measurements and showed that accumulated ions significantly affect the beam optics. For a beam current of 0.3 A, the longitudinal cooling rate was increased by factor of {approx}2 when ions were removed.

43 PARTICLE ACCELERATORS↗

High collection efficiency X-ray spectrometer system with integrated electron beam stop, electron detector and X-ray detector for use on electron-optical beam lines and microscopes

An X-ray spectrometer systems and methods are provided for implementing signal detection for use on electron-optical beam lines and microscopes. The X-ray Spectrometer System (XSS) includes an X-ray detector (XD) measuring the X-ray signal and positioned proximate to a specimen. An environmental isolation window together with an electron beam stop is disposed between XD and the specimen. The environmental isolation window and the electron beam stop protect XD from electrons directly transmitted through the specimen. An electron detector is located between the electron beam stop and the specimen allowing the measurement of scattered electrons. The XD measures an X-ray signal in the X-ray spectrometer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Spectrometry in the Era of Aberration-Corrected Electron Optical Beam Lines

Abstract Aberration correction in the analytical transmission electron microscope is most closely associated with improvements in high-resolution imaging. In this paper, the combination of that technology with new system designs, which optimize both electron optics and x-ray detection, is shown to provide more than a tenfold increase in performance over the last 25 years.

Zaluzec, Nestor J. (ORCID:0000000248573487)↗

Effects of a 4.3T superconducting wiggler on the electron beam optics and dynamics at NSLS-II

A superconducting wiggler (SCW) with a peak field of 4.3 T has recently been installed at NSLS-II. The wiggler generates a high-flux X-ray beam with a photon energy range from 20 keV to 200 keV for the High Energy Engineering X-ray Scattering beamline. This device induces significant distortions in the electron beam orbit and optics. Here, we have corrected these adverse effects using feed-forward tables. The effects of the SCW on the electron beam emittance, energy spread, and bunch length were calculated and measured. The beam-induced heating of the cryogenic vacuum chamber was also studied. Finally, the superconducting wiggler has been commissioned for user operations.

36 MATERIALS SCIENCE↗

Methods of optical diagnostics of electron-positron beams and interaction between plasma and high-current electron beam

Optical diagnostics is widely used, both in plasma-physics experiments and in measuring parameters of electron and positron beams in accelerators. In doing so, the approaches with the same methodological base are often applied, which is explained by similarity of certain properties of objects under study despite the fact that these fields of physics are absolutely specific and require using the specialized techniques. The possibility of close contacts and cooperation among scientists concerned with similar problems in different fields of physics contributes to the fruitful exchange of ideas and helps to overcome these problems. It is especially characteristic of the Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, which is famous for pioneering works in the field of electron-positron colliders and controlled thermonuclear fusion. The first part of this paper presents a review of optical diagnostics of the stationary beam parameters in cyclic accelerators of electrons and positrons. The only techniques considered are those that became the recognized tools at colliders and storage rings of the latest generation, without which the routine operation of the facility is difficult to imagine. The second part of the paper describes optical diagnostics used in experiments of heating the plasma by a high-current electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of optical beams to electrons in graphene

The technique of beam optics is applied to the description of the wave function of Dirac electrons. This approach is illustrated by considering electron transmission through simple nonhomogeneous structures, such as flat and bent p-n junctions and superlattices. We found that a convex p-n junction compresses the beam waist, while a concave interface widens it without loosing its focusing properties. At a flat p-n junction the waist of the transmitted Gaussian beam can be narrowed or widened, depending on the angle of incidence. A general condition is derived for the occurrence of beam collimation in a superlattice which is less stringent than previous discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of bunching of an electron beam at optical wavelengths

This paper presents an analysis of the bunching of an electron beam at optical wavelengths by means of the inverse Cerenkov effect. A laser light beam is used to modulate the velocity of the electrons, and this velocity modulation becomes charge-density modulation after an appropriate drift distance. The effects of energy and angular spread of the electrons are included, as well as the impact of scatterings in the index-matching medium. Bunching can occur with reasonable parameter values and the drift distance is of the order of several centimeters.

Chen, C. K.↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

Multi-component measurements of the Jefferson Lab energy recovery linac electron beam using optical transition and diffraction radiation

DOI: http://dx.doi.org/10.1103/PhysRevSTAB.11.082801 High brightness electron accelerators, such as energy recovery linacs (ERL), often have complex particle distributions that can create difficulties in beam transport as well as matching to devices such as wigglers used to generate radiation from the beam. Optical transition radiation (OTR), OTR interferometry (OTRI) and optical diffraction-transition radiation interferometry (ODTRI) have proven to be effective tools for diagnosing both the spatial and angular distributions of charged particle beams. OTRI and ODTRI have been used to measure rms divergences and optical transverse phase space mapping has been demonstrated using OTRI. In this work we present the results of diagnostic experiments using OTR and ODR conducted at the Jefferson Laboratory 115 MeV ERL which show the presence of two separate components within the spatial and angular distributions of the beam. By assuming a correlation between the spatial and angular fe

43 PARTICLE ACCELERATORS↗

Comparison endpoint study of process plasma and secondary electron beam exciter optical emission spectroscopy

Traditionally process plasmas are often studied and monitored by optical emission spectroscopy. Here, the authors compare experimental measurements from a secondary electron beam excitation and direct process plasma excitation to discuss and illustrate its distinctiveness in the study of process plasmas. They present results that show excitations of etch process effluents in a SF{sub 6} discharge and endpoint detection capabilities in dark plasma process conditions. In SF{sub 6} discharges, a band around 300 nm, not visible in process emission, is observed and it can serve as a good indicator of etch product emission during polysilicon etches. Based on prior work reported in literature the authors believe this band is due to SiF{sub 4} gas phase species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An EBIS system for rare isotope science project in Korea

An EBIS system has been designed to be used as a charge breeder for the post accelerator of an ISOL system. An electron gun, which is designed to produce a maximum current of 3 A at the beam energy of 20 kV, will be acquired from the Budker Institute, Novosibirsk. Electron beam optics calculations of the EBIS system as well as of the gun assembly have been performed using PBGUNS and TRAK. A superconducting solenoid with a maximum field of 6 T is to be used to compress the electron beam. A test stand, which includes the gun assembly and a high-power electron beam collector, is being designed and will be ready for the gun test in the end of this year. Charge breeding simulation using EBIS0D and CBSIM has been performed for a few key isotopes.

43 PARTICLE ACCELERATORS↗

Conjugate echoes of artificially injected electron beams detected optically by means of new image processing

Artificial auroral streaks were detected following two upward injections of energetic electrons (38 keV and 26 keV) from the Echo 4 rocket-borne electron accelerator. Newly developed image processing techniques are used to detect and describe the streaks. It is found that the potential of the payload remained below 1 kV during 45 mA injections at an altitude of 210 km. The echo streaks show little dispersion in time or space, suggesting that the portion of the beam returning to the northern hemisphere loss cone remained collimated and nearly monoenergetic. There was, however, a 70 percent loss in the return flux. The causes of this loss are discussed.

Hallinan, Thomas J.↗