Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron charge device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scanning transmission electron microscopy strain measurement from millisecond frames of a direct electron charge coupled device

A high-speed direct electron detection system is introduced to the field of transmission electron microscopy and applied to strain measurements in semiconductor nanostructures. In particular, a focused electron probe with a diameter of 0.5 nm was scanned over a fourfold quantum layer stack with alternating compressive and tensile strain and diffracted discs have been recorded on a scintillator-free direct electron detector with a frame time of 1 ms. We show that the applied algorithms can accurately detect Bragg beam positions despite a significant point spread each 300 kV electron causes during detection on the scintillator-free camera. For millisecond exposures, we find that strain can be measured with a precision of 1.3 Multiplication-Sign 10{sup -3}, enabling, e.g., strain mapping in a 100 Multiplication-Sign 100 nm{sup 2} region with 0.5 nm resolution in 40 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bi-directional magnetic resonance based wireless power transfer for electronic devices

In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved solid state electron-charge-storage device

Storage device is applicable in memory systems and in high-resolution arrays for light-responsive image sensing. The device offers high yield in multiple arrays and allows charge release with light striking only the edge of a metal electrode.

Kuper, A. B.↗

Sub-electron noise charge coupled devices

A charge coupled device designed for celestial spectroscopy has achieved readout noise as low as 0.6 electrons rms. A nondestructive output circuit was operated in a special manner to read a single pixel multiple times. Off-chip electronics averaged the multiple values, reducing the random noise by the square root of the number of readouts. Charge capacity was measured to be 500,000 electrons. The device format is 1600 pixels horizontal by 64 pixels vertical. Pixel size is 28 microns square. Two output circuits are located at opposite ends of the 1600 bit CCD register. The device was thinned and operated backside illuminated at -110 degrees C. Output circuit design, layout, and operation are described. Presented data includes the photon transfer curve, noise histograms, and bar-target images down to 3 electrons signal. The test electronics are described, and future improvements are discussed.

Chandler, Charles E.↗

Electron Charged Graphite-Based Hydrogen Storage Material (Final Report)

The electron-charge effects have been demonstrated to enhance hydrogen storage capacity using materials which have inherent hydrogen storage capacities. A charge control agent (CCA) or a charge transfer agent (CTA) was applied to the hydrogen storage material to reduce internal discharge between particles in a Sievert volumetric test device. GTI has tested the device under (1) electrostatic charge mode; (2) ultra-capacitor mode; and (3) metal-hydride mode. GTI has also analyzed the charge distribution on storage materials. The charge control agent and charge transfer agent are needed to prevent internal charge leaks so that the hydrogen atoms can stay on the storage material. GTI has analyzed the hydrogen fueling tank structure, which contains an air or liquid heat exchange framework. The cooling structure is needed for hydrogen fueling/releasing. We found that the cooling structure could be used as electron-charged electrodes, which will exhibit a very uniform charge distribution (because the cooling system needs to remove heat uniformly). Therefore, the electron-charge concept does not have any burden of cost and weight for the hydrogen storage tank system. The energy consumption for the electron-charge enhancement method is quite low or omitted for electrostatic mode and ultra-capacitor mode in comparison of other hydrogen storage methods; however, it could be high for the battery mode.

08 HYDROGEN↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

Piezoelectric-triboelectric heel charger to generate electricity from locomotion using level mechanism and mechanical SSHI boosting circuit

The disclosure provides an electricity generating insert for a piece of footwear, the insert can be removably placed in the heel portion, e.g. under the insole. The insert comprises a multilayer piezoelectric stack that alternatively flexes under the compression-decompression that occurs during locomotion, which flexing causes friction in the stack to generate electricity capable of charging electronic devices and the like, e.g. via a port on the footwear.

Wang, Ya↗

Two-terminal electronic charge resistance switching device

A two-terminal memory device and methods for its use are provided. In the device, a bottom electrode is electrically continuous with a first operating terminal, and a control gate electrode is electrically continuous with a second operating terminal. A stack of insulator layers comprising a hopping conduction layer and a tunnel layer is contactingly interposed between the bottom electrode and the control gate electrode. The tunnel layer is thinner than the hopping conduction layer, and it has a wider bandgap than the hopping conduction layer. The hopping conduction layer consists of a material that supports electron hopping transport.

Marinella, Matthew↗

TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence. The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron bombardment charge-coupled device /CCD/ detectors for the vacuum ultraviolet

Development work is underway at Princeton and NRL on electronic-readout imaging detectors for the VUV which are based on electron-bombardment CCD arrays and opaque alkali-halide photocathodes. These detectors provide single-photoelectron detection capability and wide dynamic range combined with almost the maximum possible quantum efficiency (in excess of 50% in the wavelength range below 1300 A). The Princeton work is based on an oblique-focusing electron optical configuration, while the NRL program is based on a Schmidt optical system with opaque photocathode. Results of preliminary tests at Princeton and overall system concepts for the Princeton and NRL cameras are discussed, and applications to possible space astronomy studies are examined.

Lowrance, J. L.↗

Supercapacitor with metal cyanometallate anode and carbonaceous cathode

A method is provided for charging a supercapacitor. The method initially provides a supercapacitor with a metal cyanometallate (MCM) particle anode, an electrolyte including a salt (DB) made up of cations (D.sup.+) anions (B.sup.-), and a cathode including carbonaceous materials (.quadrature.). The method connects an external charging device between the anode and cathode, and the charging device supplies electrons to the anode and accepting electrons from the cathode. In response to the charging device, cations are inserted into the anode while anions are absorbed on the surface of the cathode. A supercapacitor device is also presented.

Lu, Yuhao↗

Improved charge injection device and a focal plane interface electronics board for stellar tracking

An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.

Michon, G. J.↗

A Synthesis of Star Calibration Techniques for Ground-Based Narrowband Electron-Multiplying Charge-Coupled Device Imagers Used in Auroral Photometry

A technique is presented for the periodic and systematic calibration of ground-based optical imagers. It is important to have a common system of units (Rayleighs or photon flux) for cross comparison as well as self-comparison over time. With the advancement in technology, the sensitivity of these imagers has improved so that stars can be used for more precise calibration. Background subtraction, flat fielding, star mapping, and other common techniques are combined in deriving a calibration technique appropriate for a variety of ground-based imager installations. Spectral (4278, 5577, and 8446 A ) ground-based imager data with multiple fields of view (19, 47, and 180 deg) are processed and calibrated using the techniques developed. The calibration techniques applied result in intensity measurements in agreement between different imagers using identical spectral filtering, and the intensity at each wavelength observed is within the expected range of auroral measurements. The application of these star calibration techniques, which convert raw imager counts into units of photon flux, makes it possible to do quantitative photometry. The computed photon fluxes, in units of Rayleighs, can be used for the absolute photometry between instruments or as input parameters for auroral electron transport models.

Grubbs, Guy II↗

Charge-coupled-device response to electron beam energies of less than 1 keV up to 20 keV

Recent developments of backside treatment for the backside-illuminated scientifc CCD imagers have shown near-theoretical efficiency even at the short wavelength region of the spectrum. By using SEM performance comparisons of backside-treated and untreated CCDs to an electron flux varying from 1 to 100 pA and beam energy ranging from less than 1 keV up to 20 keV are obtained. The theoretical analysis, the SEM testing procedure, and the quantum efficiency measurement results are presented. It is shown, for example, that the average quantum efficiency increases from less than 1 percent for an untreated CCD to nearly 40 percent for a backside-treated CCD at a beam energy of 1 kev.

Daud, Taher↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗