Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak

An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v ⊥ and v || , while the X2 mode is dominantly sensitive to suprathermal electrons of a high v ⊥ . Finally, the modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A new synthetic correlation electron cyclotron emission diagnostic for validating nonlinear gyrokinetic simulations of electron temperature turbulence

To validate nonlinear gyrokinetic simulations of electron temperature turbulence, the experimental correlation electron cyclotron emission (CECE) measurements are to be compared using a synthetic CECE diagnostic, which generates modeled CECE measurement quantities by implementing realistic measurement parameters (e.g., spatial and wavenumber resolutions, radial location, etc.) to nonlinear gyrokinetic simulations. In this work, we calculate the radial and vertical spatial and wavenumber transfer functions, which are defined by the electron cyclotron emission emissivity radial profile and vertical probing antenna pattern, respectively. These transfer functions are applied to nonlinear gyrokinetic simulations of electron temperature turbulence using the continuum gyrokinetic code. A simultaneous comparison of the experimental electron temperature turbulence power spectrum and root-mean-square (RMS) level, as well as the radial correlation length with the new synthetic CECE diagnostic at a core location ρ ∼ 0.75 in an L-mode DIII-D tokamak plasma, is presented. Here, the preliminary result shows that the synthetic CECE output underestimates the RMS level by ∼42% and overestimates the radial correlation length by ∼40%.

Cyclotron radiation

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Fast physics-based launcher optimization for electron cyclotron current drive

With the increased urgency to design fusion pilot plants, fast optimization of electron cyclotron current drive (ECCD) launchers is paramount. Traditionally, this is done by coarsely sampling the 4D parameter space of possible launch conditions consisting of (1) the launch location (constrained to lie along the reactor vessel), (2) the launch frequency, (3) the toroidal launch angle, and (4) the poloidal launch angle. For each initial condition, a ray-tracing simulation is performed to evaluate the ECCD efficiency. Unfortunately, this approach often requires a large number of simulations (sometimes millions in extreme cases) to build up a dataset that adequately covers the plasma volume, which must then be repeated every time the design point changes. Here we adopt a different approach. Rather than launching rays from the plasma periphery and hoping for the best, we instead directly reconstruct the optimal ray for driving current at a given flux surface using a reduced physics model coupled with a commercial ray-tracing code. Repeating this throughout the plasma volume requires only hundreds of simulations, constituting a significant speedup. The new method is validated on two separate example tokamak profiles, and is shown to reliably drive localized current at the specified flux surface with the same optimal efficiency as obtained from the traditional approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Development of a compact electron cyclotron resonance accelerator for industrial and security applications

We describe the development of a novel accelerator, an electron Cyclotron Resonance Accelerator (eCRA) [1], to produce high power electron beams and X-ray beams for medical, research, sterilization, and national security applications. The several attractive features of eCRA include: a compact robust room-temperature single-cell RF cavity as the accelerating structure; continuous ampere-level high current output; and production of a self-rastering electron beam, thus eliminating the need for a separate beam scanner. Progress on the eCRA development, including numerical simulation, engineering design, and on-going experimental efforts will be reported here.

43 PARTICLE ACCELERATORS

Electron Cyclotron Emission–Based Separatrix Identification in ITER with OMFIT Synthetic Modeling

Accurate determination of the separatrix location is essential for understanding edge plasma behavior and optimizing confinement in tokamaks, especially in next-generation devices such as ITER. In this study, a synthetic microwave diagnostics module was developed and implemented in the OMFIT framework to assess the feasibility of an electron cyclotron emission–based separatrix detection method in ITER plasmas. Simulations were carried out using ITER H-mode equilibrium scenarios with different plasma density profiles and different pedestal widths. Here, the results show that the electron emission temperature profiles consistently exhibit an inversion pattern near the edge, with a well-defined minimum point that could serve as a proxy for the separatrix location. However, unlike in the DIII-D, the minimum point in ITER is systematically offset by approximately 2 cm into the scrape-off layer, independent of density or pedestal width, which is within the radial resolution range (2 to 5 cm) determined by the 500-MHz channel spacing. While the method does not provide the exact separatrix location, it offers a reliable indicator of the boundary region and has potential applications for real-time boundary monitoring in ITER and other future fusion devices.

Electron cyclotron emission

Initial electron cyclotron heating/current drive scoping study for the SMall Aspect Ratio Tokamak (SMART)

In this work an initial electron cyclotron heating/current drive (EC H&CD) scoping study is presented for the SMall Aspect Ratio Tokamak (SMART), constructed and operated by the Plasma Science and Fusion Technology (PSFT) Laboratory of the University of Seville. We consider two planned phases of operation with different magnitude of magnetic field (B 0.4, and 1 T). This EC H&CD scoping study is carried out by using the ray tracing code TRAVIS, which allows to quickly perform a series of scans on the main SMART plasma scenarios. A scan in the poloidal and toroidal launching angles is performed for the B 0.4 T plasma scenario assuming three launching locations (mid-plane, off-mid-plane, and top-launcher) and the extraordinary (X-) mode polarization. The absorption occurs at the second harmonic and, overall, the highest power absorption is obtained launching the EC beam from the top of the machine. A numerical analysis of the fundamental X-mode EC H&CD start-up regime for the B 1.0 T plasma scenario with two different wave frequencies (28 and 35 GHz) is presented showing a very high current drive efficiency.

Bertelli, Nicola [Princeton Plasma Physics Laborat

Analysis of neoclassical tearing mode stabilization experiment by electron cyclotron injection in KSTAR

We report the neoclassical tearing mode (NTM) stabilization experimental results by injection of the electron cyclotron (EC) beam in KSTAR, and its analysis with integrated modelling. In the KSTAR experiment, NTM was intentionally induced and the EC beam was injected by the plasma control system (PCS) to stabilize it. Here, the EC angle was controlled based on the minimum seeking algorithm for the island growth rate. Although the EC angle was not changed significantly, the island width significantly decreased towards the end of the experiment followed by the recovery of plasma performance. To assess the NTM stabilization experiment from a stability perspective, we performed integrated modelling with TRIASSIC utilizing the reconstructed equilibrium with magnetic diagnostics and motional stark effect diagnostics. As a result, we observed that the NTM is stabilized by EC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Electron cyclotron emission quasi-optical transmission system on the HL-3 tokamak

A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE 10 mode to the HE 11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. As a result, the newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Decoupling of peeling and ballooning thresholds for pedestal stability and reduction in ELM frequency via enhanced turbulence with edge electron cyclotron heating in DIII-D

Abstract The edge localized mode (ELM) frequency ( f ELM ) decreased by 63% when electron cyclotron heating (ECH) deposition location is shifted from ρ = 0.4 to ρ = 0.8 in DIII-D discharges where the power ratio between neutral beam injection (NBI) and ECH ( P NBI / P ECH ) is kept at ∼1. The performance of the pedestal in the ECH heated case is compared with a pure NBI reference discharge while keeping the total input power constant. All these discharges are performed at balanced input torque conditions. Furthermore, in the pure NBI discharge a strong decoupling of the peeling–ballooning (PB) thresholds is observed. The PB decoupling is preserved when the ECH is deposited at ρ = 0.8 and P NBI / P ECH ∼ 1, while the thresholds manifest a closed stability boundary when the ECH is deposited at ρ = 0.4. The inter-ELM pedestal recovery time is considerably larger for the ECH at ρ = 0.8 case. Increased pedestal turbulence is observed in beam emission spectroscopy (BES), Doppler backscattering and magnetic diagnostics for the ECH at the ρ = 0.8 case. Strong growth of a TEM-like mode is observed in BES and the mode growth is correlated with the decrease in f ELM . In view of these observations, the increased pedestal turbulence seems to be the plausible reason behind the delayed pedestal recovery following an ELM event in the ECH at ρ = 0.8 case, and the preservation of PB decoupling through temperature pedestal profile widening. TRANSP interpretative simulations show that the ECH at the ρ = 0.8 case is more susceptible to ITG/TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Overview of recent turbulence studies across multiple confinement modes at the ASDEX Upgrade tokamak using the Correlation Electron Cyclotron Emission diagnostic

This work presents an overview of recent and ongoing experimental measurements of core and edge turbulence across multiple confinement regimes using the Correlation Electron Cyclotron Emission (CECE) diagnostic at the ASDEX Upgrade (AUG) tokamak. A common goal among these investigations is to identify how the properties of the turbulent electron temperature fluctuations measured by CECE influence and regulate the unique transport characteristics of each confinement regime, including L-mode, I-mode, ELMy H-mode, and ELM-free H-mode. Optics and signal processing methods to aid in the analysis and interpretation of experimental turbulence results are also presented. These methods, and particularly the down-sampling and ensemble averaging method, are relevant to a wide variety of fusion and non-fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation

Modelling of the electron cyclotron emission burst from a laboratory tokamak plasma with loss-cone maser instability

The maser instability associated with the loss-cone distribution has been widely invoked to explain the radio bursts observed in the astrophysical plasma environment, such as aurora and corona. In the laboratory plasma of a tokamak, events reminiscent of these radio bursts have also been frequently observed as an electron cyclotron emission (ECE) burst in the microwave range (~2f ce near the last closed flux surface) during transient magnetohydrodynamic events. These bursts have a short duration of ~10 μs and display a radiation spectrum corresponding to a radiation temperature T e,rad of over 30 keV while the edge thermal electron temperature T e is only in the range of 1 keV. Suprathermal electrons can be generated through magnetic reconnection, and a loss-cone distribution can be generated through open stochastic field lines in the magnetic mirror of the near-edge region of a tokamak plasma. Radiation modelling shows that a sharp distribution gradient ∂f/∂v ⊥ > 0 at the loss-cone boundary can cause a negative absorption of ECE radiation through the maser instability. The negative absorption then amplifies the radiation so that the microwave intensity is significantly stronger than the thermal value. The significant T e,rad from the simulations suggests the potential role of the loss-cone maser instability in generating the ECE burst in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY