Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron tunneling magnetometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electron-Tunneling Magnetometer

Electron-tunneling magnetometer is conceptual solid-state device operating at room temperature, yet offers sensitivity comparable to state-of-art magnetometers such as flux gates, search coils, and optically pumped magnetometers, with greatly reduced volume, power consumption, electronics requirements, and manufacturing cost. Micromachined from silicon wafer, and uses tunneling displacement transducer to detect magnetic forces on cantilever-supported current loop.

Kaiser, William J.↗

In-situ synthesis of magnetic (NiFe{sub 2}O{sub 4}/CuO/FeO) nanocomposites

In-situ synthesis of magnetic nanocomposites with (NiFe{sub 2}O{sub 4}/CuO/FeO) crystal phases has been done using a sol-gel method by taking a non-stoichiometric composition of the precursors. The average particle size of the nanocomposites was calculated using X-ray diffraction (XRD) and high resolution tunneling electron microscope (HR-TEM) and it turns out to be {approx}20 nm. The vibrating sample magnetometer (VSM) measurements demonstrate the ferromagnetic nature of the nanocomposites. The synthesized nanocomposite was used to prepare magnetic fluid using tetramethylammonium hydroxide as a surfactant and its stability in the solution was also discussed. -- Graphical abstract: Magnetic nanocomposites containing (NiFe{sub 2}O{sub 4}/CuO/FeO) phases having particle size {approx}17 nm were synthesized by a sol-gel method. The synthesized nanocomposites exhibit ferromagnetic nature with small value of coercivity.

36 MATERIALS SCIENCE↗

Electronic, Magnetic and Optical Properties of Two Fe-based Superconductors and Related Parent Compounds

We have investigated the electronic, magnetic, and optical properties of two Fe-based superconductors and related parent compounds via three powerful techniques: scanning tunneling microscopy/spectroscopy (STM/S), high-temperature vibrating sample magnetometer (VSM), and optical transmission spectroscopy (OTS). Below the superconducting transition temperature Tc ~ 48 K, the STM/S of polycrystalline NdFeAsO0.86F0.14 reveals a single-gap feature. The quantitative fitting of STS data results in BCS like temperature dependence of the energy gap (T), with 2 (0)/kBTc ~ 4.3. Surprisingly, the tunneling spectra of BaFe2As2 single crystals show no evidence for the opening of a gap below its magnetic/structural transition temperature TMS ~ 140 K. This transition also had little impact on the transmission spectra in the wavelength range between 400 and 2400 nm. But its effect to the magnetic properties is dramatic, as reflected by the unusual magnetic susceptibility in a wide temperature range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Micromachined Transducers

Sensor systems of proposed type incorporate micromachined silicon-based structures as electrostatic force and displacement actuators and micromachined quantum-mechanical-tunneling electrodes as one form of displacement transducers, along with electronic circuits providing multiple electrical stimuli to displacement electrodes for measurement, calibration, monitoring of sensor status, and adjustment. Concept applicable to accelerometers, seismometers, geophones, magnetometers, pressure gauges, and other sensors in which phenomena of interest measured in terms of forces on, and/or displacements of, structural components. Provides completely remote measurement, control, health monitoring, treatment, and like, using telemetry commands.

Hartley, Frank T.↗

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗