Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron-beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

Source record↗

An Electron-Beam Ion-Neutralization Diagnostic for the Scorpius Radiography Accelerator

Electron beam spilling onto the beam pipe can produce positive ions that are accelerated inward into the beam body by its space charge. These ions partially neutralize the space charge, thereby causing the beam to be mismatched to the magnetic fields used for transport. A diagnostic of neutralization effects has been used on present accelerators, and in this note the feasibility of its use on a future accelerator is assessed.

43 PARTICLE ACCELERATORS↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Feasibility of non-intrusive optical diagnostic measurements in hypersonic boundary layers for flight experiments

The present investigation of possible methods for nonintrusive optical diagnostics of hypersonic vehicle boundary layers notes electron-beam fluorescence to be capable of obtaining measurements of density, temperature, and shock-front location, as well as of N2, O2, and NO concentrations. NO will be a key indicator of vehicle nose and leading edge chemistry. It is expected that laser-induced fluorescence will allow measurements of NO and O2 concentrations when compact and reliable UV lasers become available; the sensors and instrumentation for spectral resolution of fluorescence along a line emanating from the vehicle and passing through the shock front already exist.

Cattolica, R. J.↗

X-ray Pump-Probe Measurements using a Laser-Plasma Accelerator (Final Report)

This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 10 15 Wcm –2 ) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Electromagnetic radiation from beam-plasma instabilities

The mechanism by which unstable electrostatic waves of an electron-beam plasma system are converted into observed electromagnetic waves is of great current interest in space plasma physics. Electromagnetic radiation arises from both natural beam-plasma systems, e.g., type III solar bursts and kilometric radiation, and from man-made electron beams injected from rockets and spacecraft. In the present investigation the diagnostic difficulties encountered in space plasmas are overcome by using a large laboratory plasma. A finite diameter (d approximately equal to 0.8 cm) electron beam is injected into a uniform quiescent magnetized afterglow plasma of dimensions large compared with electromagnetic wavelength. Electrostatic waves grow, saturate and decay within the uniform central region of the plasma volume so that linear mode conversion on density gradients can be excluded as a possible generation mechanism for electromagnetic waves.

Stenzel, R. L.↗