At least 19 records

Analyzing Distribution Transformer Degradation with Increased Power Electronic Loads

The influx of non-linear power electronic loads into the distribution network has the potential to disrupt the existing distribution transformer operations. They were not designed to mediate the excessive heating losses generated from the harmonics. To have a good understanding of current standing challenges, a knowledge of the generation and load mix as well as the current harmonic estimations are essential for designing transformers and evaluating their performance. In this paper, we investigate a mixture of essential power electronic loads for a household designed in PSCAD/EMTdc and their potential impacts on transformer eddy current losses and derating using harmonic analysis. Our findings reveal that in the presence of high power electronic loads (especially third harmonics), increasing PV generation may worsen transformer degradation. However, with a low amount of power electronic loads, additional PV generation helps to reduce the harmonic content in the current and improve transformer performance.

eddy current, harmonics, PV, THD, power transforme↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Parameter Reduction of Composite Load Model Using Active Subspace Method

Over the past decades, the increasing penetration of distributed energy resources (DERs) has dramatically changed the power load composition in the distribution networks. The traditional static and dynamic load models can hardly capture the dynamic behavior of modern loads especially for fault-induced delayed voltage recovery (FIDVR) events. Thus, a more comprehensive composite load model with combination of static load, different types of induction motors, single-phase A/C motor, electronic load and DERs has been proposed by Western Electricity Coordinating Council (WECC). However, due to the large number of parameters and model complexity, the WECC composite load model (WECC CMLD) raises new challenges to power system studies. To overcome these challenges, in this paper, a cutting-edge parameter reduction (PR) approach for WECC CMLD based on active subspace method (ASM) is proposed. Firstly, the WECC CMLD is parameterized in a discrete-time manner for the application of the proposed method. Then, parameter sensitivities are calculated by discovering the active subspace, which is a lower-dimensional linear subspace of the parameter space of WECC CMLD in which the dynamic response is most sensitive. The interdependency among parameters can be taken into consideration by our approach. Finally, the numerical experiments validate the effectiveness and advantages of the proposed approach for WECC CMLD model.

active subspace↗

High-Fidelity Large-Signal Order Reduction Approach for Composite Load Model

With the increasing penetration of electronic loads and distributed energy resources, conventional load models cannot capture their dynamics. Therefore, a new comprehensive composite load model is developed by Western Electricity Coordinating Council (WECC). However, this model is a complex high-order non-linear system with multi-time-scale property, which poses challenges on power system studies with heavy computational burden. In order to reduce the model complexity, the authors firstly develop a large-signal order reduction (LSOR) method using singular perturbation theory. In this method, the fast dynamics are integrated into the slow ones to preserve transient characteristics of the former. Then, accuracy assessment conditions are proposed and embedded into the LSOR to improve and guarantee the accuracy of reduced-order model. Finally, the reduced-order WECC composite load model is derived by using the proposed algorithm. Overall, simulation results show that the reduced-order large-signal model significantly alleviates the computational burden while maintaining similar dynamic responses as the original composite load model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Characterization of mechanical deformation in aluminum by optical second harmonic generation

Second harmonic generation (SHG), a laser-based surface technique, was used to characterize near-surface defect evolution associated with mechanical deformation in 2024-T3 aluminum due to tensile loads. Electron backscatter diffraction (EBSD) measurements were also performed to determine the geometrically necessary dislocation density before and after tensile deformation. Comparison of the EBSD and SHG results found that dislocation density and SHG signal are inversely proportional; tensile deformation in the plastic regime led to an increase in dislocation density and a decrease in SHG response. A similar trend was seen in the SHG results on as-received (unpolished) Al samples; SHG response decreases with extent of plastic deformation. Furthermore, this study suggests that SHG has potential as a nondestructive evaluation technique.

36 MATERIALS SCIENCE↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Comparative Study of Nonlinear Black-Box Modeling for Power Electronics Converters

With the increasing penetration level of renewable sources and power electronics loads in modern power systems, accurate and computationally efficient models are needed. Black-box model (BBM) could be a useful method in such systems. However, not very extensive research efforts have been made for power electronics BBM so far, and existing works mostly focus on steady-state operation, neglecting the important transient behaviors such as load transients, voltage transients, and faults. This paper presents a comparative study of three commonly used nonlinear BBM approaches for transient behaviors of power electronics converters. Comparison methods are proposed, and the evaluations are conducted under different transients using a grid-connected single-phase photovoltaic inverter. The findings of this study provide valuable references for further feasibility investigations on implementing BBMs in large-scale power electronics-rich power systems.

Qiao, Liang↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

A Framework to Evaluate the Grid Impacts of EV Fleet Charging Solutions

Growing Electric vehicle (EV) adoption in residential and commercial applications is driving the need for the charging infrastructures required to fulfill the charging needs. The resulting increase in demand for electric power will add a significant load to the electric grid, which could negatively impact the grid operation. EVs are power electronic loads and draw harmonic currents which can lead to a host of power quality issues. Therefore, it is crucial to assess the grid impacts and management of EV charging loads to ensure the reliable operation of the electric grid. In this paper, we develop a framework to help determine power-quality impacts given an EV charging schedule on the system. We compare the performance of unmanaged and managed charging solutions on factors like voltage drop, flicker, harmonic distortion and the peak site load - based on the EV depot in Hazelwood school district. The results allow insights into operation and site design of EV depots.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gas density structure of supersonic flows impinged on by thin blades for laser-plasma accelerator targets

Density transition injection is an effective technique for controllably loading electrons into a trapped phase for laser plasma accelerators. One common technique to achieve the required fluid structure is to impinge a thin blade on the plume of a supersonic nozzle. Density transitions induced in this way are often assumed to be bow shocks and therefore sharp, but simulations and fluorescence measurements presented in this work show that in many cases of interest, the density transition accessible to a laser propagating transverse to the shock is an intercepting shock, and therefore, shock thickness and density vary with pressure, laser height, and blade position. The fluid dynamics of a supersonic nozzle impinged on by a thin, flat object are explored through simulations and relevant features are verified via planar laser-induced fluorescence measurements. Overall, the implications of the results for tuning electron beam injectors in laser plasma accelerators are discussed.

42 ENGINEERING↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ytterbium ion trap quantum computing: The current state-of-the-art

In this work, we present an overview of contemporary quantum computing with ytterbium ion traps, placing the emphasis on industry implementations. We provide brief, concrete descriptions of various key features, such as trap loading, electronic structure, qubit function, gates, error analysis, and benchmarking. We focus on the underlying science and current technologies to provide readers with a holistic picture of available techniques for using ytterbium in contemporary ion trap designs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thickness-independent scalable high-performance Li-S batteries with high areal sulfur loading via electron-enriched carbon framework

Abstract Increasing the energy density of lithium-sulfur batteries necessitates the maximization of their areal capacity, calling for thick electrodes with high sulfur loading and content. However, traditional thick electrodes often lead to sluggish ion transfer kinetics as well as decreased electronic conductivity and mechanical stability, leading to their thickness-dependent electrochemical performance. Here, free-standing and low-tortuosity N, O co-doped wood-like carbon frameworks decorated with carbon nanotubes forest (WLC-CNTs) are synthesized and used as host for enabling scalable high-performance Li-sulfur batteries. EIS-symmetric cell examinations demonstrate that the ionic resistance and charge-transfer resistance per unit electro-active surface area of S@WLC-CNTs do not change with the variation of thickness, allowing the thickness-independent electrochemical performance of Li-S batteries. With a thickness of up to 1200 µm and sulfur loading of 52.4 mg cm −2 , the electrode displays a capacity of 692 mAh g −1 after 100 cycles at 0.1 C with a low E/S ratio of 6. Moreover, the WLC-CNTs framework can also be used as a host for lithium to suppress dendrite growth. With these specific lithiophilic and sulfiphilic features, Li-S full cells were assembled and exhibited long cycling stability.

36 MATERIALS SCIENCE↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗