Search NASA⌕ Search

SEARCH · Search NASA

Results for “electroosmotic flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Theoretical prediction of stationary positions in the rectangular chamber during asymmetric electroosmotic flow

Most microscopic cell electrophoretic work depends on the theortical prediction of stationary positions by Smoluchowski and Komagata. Their theoretical solutions are based on the assumption that the electroosmotic flow in a chamber is symmetric. Because experiences with the rectangular chamber indicate that symmetric flow occurs during less than 8% of the experiments, the existing theory for stationary position determination is expanded to include the more general case of asymmetric flow. Smoluchowski's equation for symmetric electroosmotic flow in a rectangular chamber having a width much smaller than its height or length is examined. Smoluchowski's approach is used to approximate stationary positions in rectangular chambers with height/width ratios greater than 40. Support for the theoretical prediction of stationary positions using is given by three types of experimental evidence.

Source record↗

Asymmetric electroosmotic flow and mobility measurements at nonstationary positions in the rectangular chamber

The electrophoretic mobility of a cell in solution is defined by its velocity divided by the electric field strength it experiences. An obvious way to measure the mobility of cells is to apply a constant electric field to a suspension of cells in a glass chamber and clock the velocities of individual cells through a microscope. This microscope method is the classic technique in cell electrophoresis and it has been used for the bulk of research in this field. Two aspects of the microscope method can critically affect the accuracy and consistency of its cell mobility measurements: (1) the electroosmotic fluctuations in the chamber from measurement to measurement; and (2) the number of cells which can be practically measured for statistically meaningful results. A new method of analyzing microelectrophoretic data using a computer program has been developed which addresses both of these aspects. It makes possible the mobility measurements of individual cells as positions throughout the rectangular chamber depth during asymmetric electroosmotic flow.

Source record↗

A computer program for determining the electrophoretic mobility of cells in a rectangular chamber during asymmetric electroosmotic flow

In the field of cell electrophoresis, computer programs have been used for the estimation of zeta potential and surface charge density of specific charged chemical species from electrophoretic mobility data. The union of computer and microscope cell electrophoresis in the laboratory has yielded several satisfying results. The method organizes and error checks these data and stores them on permanent file for future reference or reanalysis. This computer analysis, accomplished in two steps by two main programs and a major subroutine, provides a quick, useful and realistic presentation of mobility data in histogram form, and is appropriate for any microelectrophoretic work using rectangular chambers. Computer program 1 is the first step of two in the analysis of mobility data. Program 2 consists of the main program, POLY2, which fits a least squares parabola to the apparent mobility data generated by Program 1, and the subroutine EXTRA which determines actual cell mobilities using the regression curve equation.

Source record↗

Materials processing in space - Review of the early experiments

Basic research performed to study various aspects of fluid behavior in a microgravity environment during the first two decades of spaceflight is described. The uniqueness of space was recognized in the 1950s as a place where buoyancy-driven convective flows and sedimentation would effectively be absent. The conditions were favorable for experiments in crystal growth, alloy solidification, combustion, thermocapillary flows, electroosmotic flows, Stefan flows, Soret diffusion, and solidification processes. Pre-Skylab NASA drop tower experiments and Apollo 14 and 17 experiments made in preparation for Skylab are described. Skylab welding and brazing, crystal growth, metallurgy and liquid float zone trials and Apollo-Soyuz crystal growth, electrophoresis and metallurgical experiments are summarized. SPAR rocket trials along similar lines are also outlined.

Naumann, Robert J.↗

Moving wall, continuous flow electronphoresis apparatus

This invention relates generally to electrophoresis devices and more particularly to a moving wall, continuous flow device in which an electrophoresis chamber is angularly positionable with respect to the direction of moving belt walls. A frame with an electrophoresis chamber is rotatably supported between two synchronously driven belt walls. This allows the chamber to be angularly positionable with respect to the direction of belt travel, which compensates for electroosmotic flow within the electrophoresis chamber. Injection of a buffer solution via an opening and a homogenous sample stream via another opening is performed at the end of a chamber, and collection of buffer and the fractionated species particles is done by a conventional collection array at an opposite end of the chamber. Belts are driven at a rate which exactly matches the flow of buffer and sample through the chamber, which entrains the buffer to behave as a rigid electrophoretic medium, eliminating flow distortions (Poiseuille effect). Additionally, belt material for each belt is stored at one end of the device and is taken up by drive wheels at an opposite end. The novelty of this invention particularly lies in the electrophoresis chamber being angularly positionable between two moving belt walls in order to compensate for electroosmotic flow. Additionally, new belt material is continuously exposed within the chamber, minimizing flow distortion due to contamination of the belt material by the sample.

Rhodes, Percy H.↗

Chemical Sensing and Chemoresponsive Pumping with Conical-Pore Polymeric Membranes

Synthetic membranes containing asymmetrically shaped pores have been shown to rectify the ionic current flowing through the membrane. Ion-current rectification means that such membranes produce nonlinear current–voltage curves analogous to those observed with solid-state diode rectifiers. In order to observe this ion-current rectification phenomenon, the asymmetrically shaped pores must have pore-wall surface charge. Pore-wall surface charge also allows for electroosmotic flow (EOF) to occur through the membrane. We have shown that, because ion-current is rectified, EOF is likewise rectified in such membranes. This means that flow through the membrane depends on the polarity of the voltage applied across the membrane, one polarity producing a higher, and the opposite producing a lower, flow rate. As is reviewed here, these ion-current and EOF rectification phenomena are being used to develop new sensing technologies. Results obtained from an ion-current-based sensor for hydrophobic cations are reviewed. In addition, ion-current and EOF rectification can be combined to make a new type of device—a chemoresponsive nanofluidic pump. This is a pump that either turns flow on or turns flow off, when a specific chemical species is detected. Results from a prototype Pb 2+ chemoresponsive pump are also reviewed here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of coating rectangular microscopic electrophoresis chamber with methylcellulose

One of the biggest problems in obtaining high accuracy in microscopic electrophoresis is the parabolic flow of liquid in the chamber due to electroosmotic backflow during application of the electric field. In chambers with glass walls the source of polarization leading to electroosmosis is the negative charge of the silicare and other ions that form the wall structure. It was found by Hjerten, who used a rotating 3.0 mm capillary tube for free zone electrophoresis, that precisely neutralizing this charge was extremely difficult, but if a neutral polymer matrix (formaldehyde fixed methylcellulose) was formed over the glass (quartz) wall the double layer was displaced and the viscosity at the shear plane increased so that electroosmotic flow could be eliminated. Experiments were designed to determine the reliability with which methylcellulose coating of the Zeiss Cytopherometer chamber reduced electroosmotic backflow and the effect of coating on the accuracy of cell electrophoretic mobility (EPN) determinations. Fixed rat erythrocytes (RBC) were used as test particles.

Plank, L. D.↗

Field-effect Flow Control in Polymer Microchannel Networks

A new Bio-MEMS electroosmotic flow (EOF) modulator for plastic microchannel networks has been developed. The EOF modulator uses field-effect flow control (FEFC) to adjust the zeta potential at the Parylene C microchannel wall. By setting a differential EOF pumping rate in two of the three microchannels at a T-intersection with EOF modulators, the induced pressure at the intersection generated pumping in the third, field-free microchannel. The EOF modulators are able to change the magnitude and direction of the pressure pumping by inducing either a negative or positive pressure at the intersection. The flow velocity is tracked by neutralized fluorescent microbeads in the microchannels. The proof-of-concept of the EOF modulator described here may be applied to complex plastic ,microchannel networks where individual microchannel flow rates are addressable by localized induced-pressure pumping.

Sniadecki, Nathan↗

Molecular dynamics and continuum analyses of the electrokinetic zeta potential in nanostructured slit channels

This work presents a theoretical and numerical study of electrokinetic flow and the zeta potential for the case of slit channels with nanoscale surface features of dimensions comparable to the Debye length, by employing molecular dynamics simulations and continuum-level analyses. Additionally, a simple analytical model for considering the average effect of such surface features producing nanoscale roughness is proposed by employing matched asymptotic solutions for the charge density and fluid flow field, and matching conditions that satisfy electroneutrality and the Onsager reciprocal relation between the electroosmotic flow rate and streaming current. The proposed analytical model quantitatively accounts for results from molecular dynamics simulations that consider the presence of ion solvation shells and surface hydration layers. Our analysis indicates that a simultaneous knowledge of the electroosmotic and pressure-driven flow rate or streaming current can be instrumental to unambiguously determine the zeta potential in the presence of nanoscale surface features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field Effect Flow Control in a Polymer T-Intersection Microfluidic Network

We present a study of induced pressure pumping in a polymer microchannel due to differential electroosmotic flow @OF) rates via field-effect flow control (FEFC). The experimental results demonstrate that the induced pressure pumping is dependent on the distance of the FEFC gate from the cathodic gate. A proposed flow model based on a linearly-decaying zeta potential profile is found to successfully predict experimental trends.

Sniadecki, Nathan J.↗

Electrophoresis experiment for space

The Apollo 16 electrophoresis experiment was analyzed, demonstrating that the separation of the two different-size monodisperse latexes did indeed take place, but that the separation was obscured by the pronounced electroosmotic flow of the liquid medium. The results of this experiment, however, were dramatic since it is impossible to carry out a similar separation on earth. It can be stated unequivocally from this experiment that any electrophoretic separation will be enhanced under microgravity conditions. The only question is the degree of this enhancement, which can be expected to vary from one experimental technique to another. The low-electroosmotic-mobility coating (Z6040-MC) developed under this program was found to be suitable for a free-fluid electrophoretic separation such as the experiment designed for the ASTP flight. The problem with this coating, however, is that its permanency is limited because of the slow desorption of the methylcellulose from the coated surface.

Vanderhoff, J. W.↗

Selective Ion Enrichment and Charge Storage through Transport Hysteresis in Conical Nanopipettes

Greater selectivity and controls in the ion transport dynamics are essential in fields such as charge storage, separation, energy storage and conversion, neuromorphic computing and learning, electrochemistry, to name a few. Mechanistic insights into the intriguing hysteresis effects in the rectified electrokinetic transport through single conical nanopipettes are unveiled by combining time-resolved electroanalytical experiments with numeric simulation. Cations as counterions for surface charges are found to dominate not just the through-nanopore flux but also the hysteresis charges, that is, the net enriched or expelled charges during the transport process. Built on our earlier report on the through-nanopore ion flux dominated by counterions for surface charges, the “trapped ions” or hysteresis charges are analyzed herein. Cation selectivity is almost 100% in the hysteresis charges during the potential scans in low conductivity states driven by the combined applied and intrinsic surface electrical fields. Surprisingly, the cation selectivity in the total hysteresis charges remains high at 70–80% over a wide bulk concentration range in the high conductivity (HC) states, where higher ionic strength due to ion enrichment would decrease electrostatistic effects and thus ion selectivity. The retained high selectivity at HC is explained by the competition effects of electroosmotic flow against the co-ion migration. Furthermore, the respective cation and anion portions in the total hysteresis charges over a wide range of ionic strength and measurement conditions provide generalizable strategies for improvements in both transport throughput and selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and characterization of methacrylate hydrogels for zeta potential control

A technique based on the measurement of streaming potentials has been developed to evaluate the effects of hydrophilic coatings on electroosmotic flow. The apparatus and procedure are described as well as some results concerning the electrokinetic potential of glass capillaries as a function of ionic strength, pH, and temperature. The effect that turbulence and entrance flow conditions have on accurate streaming potential measurements is discussed. Various silane adhesion promoters exhibited only a slight decrease in streaming potential. A coating utilizing a glycidoxy silane base upon which methylcellulose is applied affords a six-fold decrease over uncoated tubes. Hydrophilic methacrylate gels show similar streaming potential behavior, independent of the water content of the gel. By introduction of positive or negative groups into the hydrophilic methacrylate gels, a range of streaming potential values are obtained having absolute positive or negative signs.

Gregonis, D. E.↗

Countercurrent distribution of biological cells

A neutral polymer phase system consisting of 7.5 percent dextran 40/4.5 percent PEG 6, 0.11 M Na phosphate, 5 percent fetal bovine serum (FBS), pH 7.5, was developed which has a high phase droplet electrophoretic mobility and retains cell viability over many hours. In this and related systems, the drop mobility was a linear function of drop size, at least in the range 4-30 micron diameter. Applications of and electric field of 4.5 v/cm to a system containing 10 percent v/v bottom phase cleared the system more than two orders of magnitude faster than in the absence of the field. At higher bottom phase concentrations a secondary phenomenon intervened in the field driven separations which resulted in an increase in turbidity after clearing had commenced. The increase was associated with a dilution of the phase system in the chamber. The effect depended on the presence of the electric field. It may be due to electroosmotic flow of buffer through the Amicon membranes into the sample chamber and flow of phase system out into the rinse stream. Strategies to eliminate this problem are proposed.

Brooks, D. E.↗

Evaluation of results of cell electrophoresis experiments on space shuttle STS-3 including pre-flight and post-flight laboratory experiments

The objectives of the red blood cell experiments were to provide a visual check on the electrophoretic process and especially electroosmotic flow in space as well as to provide test separations of non-degradable standard particles for comparison with the separations of the three viable cell types studied on the Apollo-Soyuz Test Project. Determination of the maximum concentrations of cells that can be separated in column electrophore was a significant goal. Two of the eight columns were available for red cell experiments, so two concentrations of human and rabbit RBC mixtures were used. The objectives of another experiment were to evaluate the reproducibility of microgravity electrophoretic separation of living kidney cells, to separate cells with highly viability despite two freeze-thaw cycles, and to optimize the physical conditions of cell separation. Owing to the uncertain heterogeneity of the starting material, the experimental design does not assess resolution in microgravity, but improved separability was sought in comparison to density-gradient electrophoresis or continuous-flow electrophoresis. Efforts were made to increase cell yield and cell viability and to assess reproducibility directly.

Todd, P. W.↗

Computer simulation of immobilized pH gradients at acidic and alkaline extremes - A quest for extended pH intervals

Computer simulations of the concentration profiles of simple biprotic ampholytes with Delta pKs 1, 2, and 3, on immobilized pH gradients (IPG) at extreme pH values (pH 3-4 and pH 10-11) show markedly skewed steady-state profiles with increasing kurtosis at higher Delta pK values. Across neutrality, all the peaks are symmetric irrespective of their Delta pK values, but they show very high contribution to the conductivity of the background gel and significant alteration of the local buffering capacity. The problems of skewness, due to the exponential conductivity profiles at low and high pHs, and of gel burning due to a strong electroosmotic flow generated by the net charges in the gel matrix, also at low and high pHs, are solved by incorporating in the IPG gel a strong viscosity gradient. This is generated by a gradient of linear polyacrylamide which is trapped in the gel by the polymerization process.

Mosher, Richard A.↗