Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrostatic discharges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Desensitizing nano powders to electrostatic discharge ignition

Electrostatic discharge (ESD) is a main cause for ignition in powder media ranging from grain silos to fireworks. Nanoscale particles are orders of magnitude more ESD ignition sensitive than their micron scale counterparts. This study shows that at least 13 vol. % carbon nanotubes (CNT) added to nano-aluminum and nano-copper oxide particles (nAl + CuO) eliminates ESD ignition sensitivity. The CNT act as a conduit for electric energy and directs electric charge through the powder to desensitize the reactive mixture to ignition. For nanoparticles, the required CNT concentration for desensitizing ESD ignition acts as a diluent to quench energy propagation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Low-voltage detonator response to electrostatic discharge

Most explosives exhibit some level of sensitivity to electrostatic discharge. Low-voltage detonators (a.k.a blasting caps) are commonly referred to as Low-Energy Electro-explosive Devices (LEEED), a category that may indicate elevated sensitivity to induced current and/or electrostatic discharge (ESD). These devices comprise a resistive bridge wire (~ 2 Ω) surrounded by a pyrotechnic or primary explosive such as lead styphnate, in contact with a primary explosive charge, typically dextrinated lead azide, followed by an output charge, generally PETN. The 50% firing current is typically around 1 A.

42 ENGINEERING↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Electrostatic charge buildup and electrostatic discharge monitoring system and method

A system for monitoring electrostatic charge buildup and electrostatic discharge (ESD) remotely comprises a plurality of electrostatic charge measurement units and a data acquisition device. Each electrostatic charge measurement unit includes a primary charge plate, a static sensor device, a secondary charge plate, and a shielded cable. The primary charge plate is positioned proximal to an object. The static sensor device includes an input sensor at which an electric voltage is measured and outputs an electronic signal whose level varies according to the measured electric voltage. The secondary charge plate is positioned in proximity to the input sensor of the static sensor device. The shielded cable includes an inner conductor electrically connected to the primary charge plate and the secondary charge plate and an outer conductor electrically connected to electrical ground. The data acquisition device receives the electronic signal from the static sensor device of each electrostatic charge measurement unit.

Schantz, Eric T.↗

Controlling the Electrostatic Discharge Ignition Sensitivity of Composite Energetic Materials Using Carbon Nanotube Additives

Powder energetic materials are highly sensitive to electrostatic discharge (ESD) ignition. This study shows that small concentrations of carbon nanotubes (CNT) added to the highly reactive mixture of aluminum and copper oxide (Al + CuO) significantly reduces ESD ignition sensitivity. CNT act as a conduit for electric energy, bypassing energy buildup and desensitizing the mixture to ESD ignition. The lowest CNT concentration needed to desensitize ignition is 3.8 vol.% corresponding to percolation corresponding to an electrical conductivity of 0.04 S/cm. Conversely, added CNT increased Al + CuO thermal ignition sensitivity to a hot wire igniter.

36 MATERIALS SCIENCE↗

Physics Guided Simulation of Electrostatic Discharge: Technical Report

Triboelectrically-charged objects may create threshold sparks, electrostatic discharge (ESD) events, to equilibrate charge between themselves and other relatively charged objects. ESD events exhibit many complex physical phenomena. They are a nexus of several fields of physics with disparate characteristic scales: plasma physics, chemical kinetics, hydrodynamics, circuit models, etc. These scales can span many orders of magnitude from the varied collisions thermalizing information within a plasma on the $\mathcal{O}(fs/ps)$ to the physical size of the plasma channel on the $\mathcal{O}(100µm)$, to the speed of a nonlinear hydrodynamic wave propagating at $\mathcal{O}(µm, ns)$. These threshold ESD events may occur in situations of programmatic importance, delivering energy and power profiles to a “victim load” generating deleterious consequences. To predict and mitigate these consequences we must answer questions about the spark’s energy budget: how much energy goes into producing the spark channel; how much gets radiated away; how much energy is advected away into the hydrodynamics; and how much energy is delivered to a victim load. An ESD simulation toolset has been created and evolved in order to answer these questions. An appropriate, physics guided implementation for simulation can be done by gaining insight into its constituent physics and leveraging that intuition to choose a suitable numerical operator. We examine in detail the chemical kinetics, circuit discharge, and hydrodynamics to deter mine dominant regimes, values, timescales, and interactions to uncover the underlying physical dynamics. We also examine and propose model reduction schemes for high-dimensional chemical kinetics. We use past and current work with experimentally validated and theoretically-verified hydrodynamics to calculate applicability limits of the non-ionizing strong shock limit. We quantify the energy budget from a hydrodynamic perspective and demonstrate that a significant fraction of the stored energy is “earmarked” for hydrodynamic advection as an energy terminus. Lastly, we combine the constituent physics of an ESD event (chemical kinetics, circuit model, and hydrodynamics) into a cohesive, actionable toolset and obtain promising results from an isothermal test case. We then propose a viable, modular evolution of the ESD toolset based upon the performed examination of the physics uncovering dominant physical scales and the stiffness of the compositional differential system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling of energy delivered through an electrostatic discharge to a small series load

We study the energy delivered through a small-resistance series “victim” load during electrostatic discharge events in air. For gap lengths over 1 mm, the fraction of the stored energy delivered is mostly gap-length independent, with a slight decrease at larger gaps due to electrode geometry. The energy to the victim scales linearly with circuit capacitance and victim load resistance but is not strongly dependent on circuit inductance. This scaling leads to a simple approach to predicting the maximum energy that will be delivered to a series resistance for the case where the victim load resistance is lower than the spark resistance.

42 ENGINEERING↗

Synthesizing aluminum particles towards controlling electrostatic discharge ignition sensitivity

Aluminum particles were synthesized with shell thicknesses ranging from 2.7 to 8.3 nm and a constant diameter of 95 nm. These fuel particles were combined with molybdenum trioxide particles and the electrostatic discharge (ESD) sensitivity of the mixture was measured. Results show ignition delay increased as the alumina shell thickness increased. These results correlated with electrical resistivity measurements of the mixture which increased with alumina concentration. A model was developed using COMSOL for ignition of a single Al particle. The ignition delay in the model was consistent with the experimental results suggesting that the primary ESD ignition mechanism is joule heating.

99 GENERAL AND MISCELLANEOUS↗

Effects of electrostatic discharge on three cryogenic temperature sensor models

Cryogenic temperature sensors are not usually thought of as electrostatic discharge (ESD) sensitive devices. However, the most common cryogenic thermometers in use today are thermally sensitive diodes or resistors - both electronic devices in their base form. As such, they are sensitive to ESD at some level above which either catastrophic or latent damage can occur. Instituting an ESD program for safe handling and installation of the sensor is costly and it is desirable to balance the risk of ESD damage against this cost. However, this risk cannot be evaluated without specific knowledge of the ESD vulnerability of the devices in question. This work examines three types of cryogenic temperature sensors for ESD sensitivity - silicon diodes, Cernox(trade mark, serif) resistors, and wire wound platinum resistors, all manufactured by Lake Shore Cryotronics, Inc. Testing was performed per TIA/EIA FOTP129 (Human Body Model). Damage was found to occur in the silicon diode sensors at discharge levels of 1,500 V. For Cernox(trade mark, serif) temperature sensors, damage was observed at 3,500 V. The platinum temperature sensors were not damaged by ESD exposure levels of 9,900 V. At the lower damage limit, both the silicon diode and the Cernox(trade mark, serif) temperature sensors showed relatively small calibration shifts of 1 to 3 K at room temperature. The diode sensors were stable with time and thermal cycling, but the long term stability of the Cernox(trade mark, serif) sensors was degraded. Catastrophic failure occurred at higher levels of ESD exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic Discharge Sensitivity and Electrical Conductivity of Composite Energetic Materials

Composite energetic material response to electrical stimuli was investigated and a correlation between electrical conductivity and ignition sensitivity was examined. The composites consisted of micrometer particle aluminum combined with another metal, metal oxide, or fluoropolymer. Of the nine tested mixtures, aluminum with copper oxide was the only mixture to ignite by electrostatic discharge with minimum ignition energy (MIE) of 25 mJ and an electrical conductivity of 1246.25 nS; two orders of magnitude higher than the next composite. This study showed a similar trend in MIE for ignition triggered by a discharged spark compared with a thermal hot wire source.

36 MATERIALS SCIENCE↗

PSL-AC-CP-1102-004-03: Electrostatic Discharge Simulator Kit Model 930D and Associated Current-Viewing Resistor (V.04)

This document provides instructions for calibrating the Electro-Tech (ETS) electrostatic discharge (ESD) simulator, Model 930D. The calibration shall meet the ± 5% specification for resistance and capacitance as specified in MIL-STD-331C 2009 newer. A series of direct measurements of the Device Under Test (DUT) output at 25 kV using a calibrated LeCroy HDO 6104 oscilloscope (or equivalent 1 MΩ) input impedance storage oscilloscope) are recorded through the 500-pF capacitor, 500-Ω resistor, and a 1-Ω Current Viewing Resistor (CVR). The certified value of the DUT's 25 kV output is calculated using Ohms Law and the certified system resistance and capacitance described in this procedure. Read this document in its entirety before proceeding with the calibration.

42 ENGINEERING↗

High-Power Electrostatic Discharges in PETN: Threshold and Scaling Experiments

There is a considerable set of data establishing the safety of PETN-based detonators that are insulted by electrostatic discharge (ESD) from a human body. However, the subject of ESD safety has garnered renewed interest because of the sparse data on high-power, low-impedance discharges that result when the source is a metallic object such as a tool. Experiments on as-built components, using pin-to-cap fault circuits through PETN-based detonators, showed significant evidence of a power dependence but with a very broad energy threshold and some uncertainty in the breakdown path. We have performed a series of experiments using a well-defined arc discharge path and a well-characterized source that is capable of independent variation of energy and power. Studies include threshold variation with power, arc length, powder surface area, and surface vs. bulk discharge paths. We find that an energy threshold variation with power does not appear to exist in the tested range of fractions to tens of MW, and that there are many subtleties to proper energy and power bookkeeping. We also present some test results for PBX 9407.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On Hydrodynamics Generated from Electrostatic Discharges: A Heat Source Perspective

A parameter space map of a heat source depositing energy into a cylindrical spark channel modeling the hydrodynamic effects of an electrostatic discharge event is explored. The four parameters of spatial weight, λ R , rise time, τ r , fall time, τ f , and energy per unit length deposited in to the system, E 0 /h, were varied to observe resulting hydrodynamic phenomena. The energy budget con-sequences of the associated hydrodynamic flow are discussed in terms of the remaining electrical energy available for the joule heating of sensitive energetic materials (or “victims”) are discussed,where hydrodynamic simulations are validated by experimental data. Future results and conclusions will be added to this report as they are produced.

24 POWER TRANSMISSION AND DISTRIBUTION↗

THE ALLEN TELESCOPE ARRAY SEARCH FOR ELECTROSTATIC DISCHARGES ON MARS

The Allen Telescope Array was used to monitor Mars between 2010 March 9 and June 2, over a total of approximately 30 hr, for radio emission indicative of electrostatic discharge. The search was motivated by the report from Ruf et al. of the detection of non-thermal microwave radiation from Mars characterized by peaks in the power spectrum of the kurtosis, or kurtstrum, at 10 Hz, coinciding with a large dust storm event on 2006 June 8. For these observations, we developed a wideband signal processor at the Center for Astronomy Signal Processing and Electronics Research. This 1024 channel spectrometer calculates the accumulated power and power-squared, from which the spectral kurtosis is calculated post-observation. Variations in the kurtosis are indicative of non-Gaussianity in the signal, which can be used to detect variable cosmic signals as well as radio frequency interference (RFI). During the three-month period of observations, dust activity occurred on Mars in the form of small-scale dust storms; however, no signals indicating lightning discharge were detected. Frequent signals in the kurtstrum that contain spectral peaks with an approximate 10 Hz fundamental were seen at both 3.2 and 8.0 GHz, but were the result of narrowband RFI with harmonics spread over a broad frequency range.

79 ASTRONOMY AND ASTROPHYSICS↗

Spark Channel Dynamics of Electrostatic Discharges

When two differently-charged objects are brought in close proximity to each other, the resulting high electric fields can cause electron avalanche breakdown of the air gap separating the objects, a process known as electrostatic discharge (ESD). If enough initial charge is stored on the objects, the electrical breakdown can proceed to ionize the air to such a degree that a highly conductive filament of plasma forms in the gap, known as a spark channel. The spark electrically bridges the air gap, resulting in a rapid pulse of current that neutralizes the charge difference. The current pulse produces significant heating of the gas in the spark, resulting in dissociation, ionization, thermal radiation, and hydrodynamic expansion. ESD presents a hazard to electrically-sensitive devices, with consequences such as economic losses (e.g. damaged electronics) or unsafe response (e.g. unintended ignition of flammable gas mixtures, initiation of detonators, etc.). For this thesis, the ESD spark is taken to occur between two conducting electrodes, with the spark channel being axisymmetric in a cylindrical coordinate system centered on the channel. An RLC-type circuit is used for the discharge model of the ESD event. The spark is treated as a time-dependent resistance that is in series with a capacitance, an inductance, and (optionally) a load resistance representing a “victim” component under threat from the ESD event. The primary motivation of this work is to use a numerical hydrodynamic model to understand the energy dissipation and transport processes in the spark. The model consists of the compressible Euler equations of mass, momentum, and energy conservation together with an Eddington/P1 approximation for thermal radiation transport. To close the hydrodynamic system, an equation of state (EOS) was fitted from tabular data for air that accounts for the dissociation and ionization of air species. The hydrodynamic equations are solved using a conservative Lagrangian finite volume method. These partial differential equations are coupled to the circuit equations by calculation of the spark resistance via numerical integration of the electrical conductivity of the channel. Computational results are compared against experimental measurements of discharge current and radial density of the spark channel.

42 ENGINEERING↗

The Effects of Electrostatic Discharge Phenomena on Detonator Response: A Framework for Evaluating Parameters Relevant to Quantification of Margins and Uncertainties

Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Pantex are collaborating on a Nuclear Safety Research & Development (NSR&D) project to develop a common Quantification of Margins and Uncertainties (QMU) framework for explosive safety analysis. An analysis of electrostatic discharge (ESD) data serves as an initial test case for methodology development. This analysis examines measurements of electrical characteristics of production environments, tests designed to measure ESD response of detonators, and information on interactions between variables drawn from expert knowledge and physics models.

42 ENGINEERING↗

COMMENTS ON THE SEARCH FOR ELECTROSTATIC DISCHARGES ON MARS

Ruf et al. used the Deep Space Network (DSN) to search for the emission of non-thermal radiation by martian dust storms, theoretically predicted by Renno et al. They detected the emission of non-thermal radiation that they were searching for, but were surprised that it contained spectral peaks suggesting modulation at various frequencies and their harmonics. Ruf et al. hypothesized that the emission of non-thermal radiation was caused by electric discharges in a deep convective dust storm, modulated by Schumann resonances (SRs). Anderson et al. used the Allen Telescope Array (ATA) to search for similar emissions. They stated that they found only radio frequency interference (RFI) during their search for non-thermal emission by martian dust storms and implicitly suggested that the signal detected by Ruf et al. was also RFI. However, their search was not conducted during the dust storm season when deep convective storms are most likely to occur. Here, we show that the ubiquitous dust devils and small-scale dust storms that were instead likely present during their observations are too shallow to excite SRs and produce the signals detected by Ruf et al. We also show that the spectral and temporal behavior of the signals detected by Anderson et al. corroborates the idea that they originated from man-made pulse-modulated telecommunication signals rather than martian electric discharges. In contrast, an identical presentation of the signals detected by Ruf et al. demonstrates that they do not resemble man-made signals. The presentation indicates that the DSN signals were consistent with modulation by martian SRs, as originally hypothesized by Ruf et al. We propose that a more comprehensive search for electrostatic discharges be conducted with either the ATA or DSN during a future martian dust storm season to test the hypothesis proposed by Ruf et al.

79 ASTRONOMY AND ASTROPHYSICS↗