Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrothermal simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimentation in the low-density plume of a simulated electrothermal thruster for computer code validation

Pressures and flow angles are measured in the plume of a 20 deg half-angle, conical nozzle in vacuum with Pitot tubes and conical probes. The area of measurement in the plume ranges from the nozzle exit plane to 480 mm axially downstream and from the plume centerline to 60 mm radially. The nozzle has an exit-to-throat area ratio of 100:1 and a throat diameter of 3.2 mm. The nozzle flow exhausts to a vacuum of order 10(exp -2) Pa to simulate a resistojet (an electrothermal rocket of less than 1 N of thrust) operating in space. Experimental data are given for flows of nitrogen at 55 and 68 mg/s, stagnation temperatures between 695 and 921 K, and stagnation pressures ranging from 5600 to 7100 Pa. Data are also given for argon at a rate of 68 mg/s, a stagnation temperature of 648 K, and stagnation pressures of 4500, 4750, and 4770 Pa. Measurements in the nitrogen plume are compared with computational results from a direct-simulation Monte Carlo method.

Meissner, Dana L.↗

Numerical simulation of electrothermal de-icing systems

Transient simulations of de-icing of composite aircraft components by electrothermal heating have been computed for both one and two-dimensional rectangular geometries. The implicit Crank-Nicolson formulation is used to insure stability of the finite-differenced heat conduction equations and the phase change in the ice layer is simulated using the Enthalpy method. Numerical solutions illustrating de-icer performance for various composite aircraft blades and environmental conditions are presented. Comparisons are made with previous studies and with available experimental data. Initial results using a coordinate mapping technique to describe the actual blade geometry are discussed.

De Witt, K. J.↗

Numerical simulation of an electrothermal deicer pad

A numerical simulation is developed to investigate the removal of ice from composite aircraft blades by means of electrothermal deicing. The model considers one dimensional, unsteady state heat transfer in the composite blade-ice body. The heat conduction equations are approximated by using the Crank-Nicolson finite difference scheme, and the phase change in the ice layer is handled using the Enthalpy method. To solve the system of equations which result, Gauss-Seidel iteration is used. The simulation computes the temperature profile in the composite blade-ice body, as well as the movement of the ice-water interface, as a function of time. This information can be used to evaluate deicer performance. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Marano, J. J.↗

Validation of NASA Thermal Ice Protection Computer Codes: Program Overview - Part 1

The Icing Technology Branch at NASA Lewis has been involved in an effort to validate two thermal ice protection codes developed at the NASA Lewis Research Center. LEWICE/Thermal (electrothermal deicing & anti-icing), and ANTICE (hot-gas & electrothermal anti-icing). The Thermal Code Validation effort was designated as a priority during a 1994 'peer review' of the NASA Lewis Icing program, and was implemented as a cooperative effort with industry. During April 1996, the first of a series of experimental validation tests was conducted in the NASA Lewis Icing Research Tunnel(IRT). The purpose of the April 96 test was to validate the electrothermal predictive capabilities of both LEWICE/Thermal, and ANTICE. A heavily instrumented test article was designed and fabricated for this test, with the capability of simulating electrothermal de-icing and anti-icing modes of operation. Thermal measurements were then obtained over a range of test conditions, for comparison with analytical predictions. This paper will present an overview of the test, including a detailed description of: (1) the validation process; (2) test article design; (3) test matrix development; and (4) test procedures. Selected experimental results will be presented for de-icing and anti-icing modes of operation. Finally, the status of the validation effort at this point will be summarized. Detailed comparisons between analytical predictions and experimental results are contained in the following two papers: 'Validation of NASA Thermal Ice Protection Computer Codes: Part 2- The Validation of LEWICE/Thermal' and 'Validation of NASA Thermal Ice Protection Computer Codes: Part 3-The Validation of ANTICE'

Miller, Dean↗

2D Magnetohydrodynamic Simulations of the Electrothermal Instability in Metallic Liners

The Virginia Tech (VT) Plasma Dynamics Laboratory Computational (PDCL) and Lawrence Livermore National Laboratory (LLNL) are performing two dimensional (2D) simulations of the electrothermal instability (ETI) using the LLNL multi-physics code Ares. Ares is a multi-physics arbitrary–Lagrangian-Eulerian (ALE) code developed by LLNL and is of particular use in studying magnetohydrodynamic (MHD) instabilities like the ETI due to its resistive MHD, magnetic diffusion, and radiative-hydrodynamics packages. Among its capabilities, it has the ability to model material strength, perform adaptive mesh refinement (AMR), and incorporate a wide variety of equations of state models and conductivity models. The 2D Ares simulation model created by VT-LLNL for studying the development and growth of the electrothermal instability has been configured with initial conditions based on the Mykonos Electrothermal Instability II (METI-II) experiments described by this grant and conducted by team members at the University of Nevada (UNR), the University of New Mexico (UNM), and Sandia National Laboratories. Previously, preliminary 2D Ares simulations of the ETI had been run to approximately 80ns. The rods in these simulations were initiated with sinusoidal perturbations at a similar order of magnitude to those measured on the aluminum rods used for the Mykonos experiment. This model has been improved by increasing the spatial resolution of the simulations and running the simulations further in time. In addition to the simulation run-times extending, the preliminary sinusoidal perturbation has been replaced with a perturbation derived from amplitude measurements by the experimental team, thereby correlating the simulation inputs better to the experimental runs. These new runs are capable of reaching 120ns of simulated time for the uncoated cases and to 200ns the 41 μm coated cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient numerical simulation of an electrothermal de-icer pad

In this paper, a new approach to calculate the transient thermal behavior of an iced electrothermal de-icer pad was developed. The method of splines was used to obtain the temperature distribution within the layered pad. Splines were used in order to create a tridiagonal system of equations that could be directly solved by Gauss elimination. The Stefan problem was solved using the enthalpy method along with a recent implicit technique. Only one to three iterations were needed to locate the melt front during any time step. Computational times were shown to be greatly reduced over those of an existing one dimensional procedure without any reduction in accuracy; the curent technique was more than 10 times faster.

Roelke, R. J.↗

Model Reduction by Generalized Falk Method for Efficient Field-Circuit Simulations

The Generalized Falk Method (GFM) for coordinate transformation, together with two model-reduction strategies based on this method, are presented for efficient coupled field-circuit simulations. Each model-reduction strategy is based on a decision to retain specific linearly-independent vectors, called trial vectors, to construct a vector basis for coordinate transformation. The reduced-order models are guaranteed to be stable and passive since the GFM is a congruence transformation of originally symmetric positive definite systems. We also show that, unlike the Pad´e-via-Lanczos (PVL) method, the GFM does not generate unstable positive poles while reducing the order of circuit problems. Further, the proposed GFM is also faster when compared to methods of the type Lanczos (or Krylov) that are already widely used in circuit simulations for electrothermal and electromagnetic problems. The concept of response participation factors is introduced for the selection of the trial vectors in the proposed model-reduction methods. Further, we present methods to develop simple equivalent circuit networks for the field component of the overall field-circuit system. The implementation of these equivalent circuit networks in circuit simulators is discussed. With the proposed model-reduction strategies, significant improvement on the efficiency of the generalized Falk method is illustrated for coupled field-circuit problems.

42 ENGINEERING↗

Validation of NASA Thermal Ice Protection Computer Codes: The Validation of Antice - Part 3

An experimental program was generated by the Icing Technology Branch at NASA Glenn Research Center to validate two ice protection simulation codes: (1) LEWICE/Thermal for transient electrothermal de-icing and anti-icing simulations, and (2) ANTICE for steady state hot gas and electrothermal anti-icing simulations. An electrothermal ice protection system was designed and constructed integral to a 36 inch chord NACA0012 airfoil. The model was fully instrumented with thermo-couples, RTD'S, and heat flux gages. Tests were conducted at several icing environmental conditions during a two week period at the NASA Glenn Icing Research Tunnel. Experimental results of running-wet and evaporative cases were compared to the ANTICE computer code predictions and are presented in this paper.

Al-Khalil, Kamel M.↗

Predicted electrothermal deicing of aircraft blades

A finite difference method is presented for the transient two-dimensional simulation of an electrothermal de-icer pad of an aircraft wing or blade. The irregular geometry of the composite ice laden blade is handled by use of a body fitted coordinate transformation. By this approach the various blade layers are mapped into a set of stacked rectangular strips in which the numerical solution takes place. Several heat conduction examples are presented in order to demonstrate the accuracy of the numerical procedure. Ice melting time predictions are made and compared to earlier predictions where possible. Finally, a new graphical presentation of thermal results is shown.

Keith, T. G., Jr.↗

A comparison of numerical methods for the prediction of two-dimensional heat transfer in an electrothermal deicer pad

Transient, numerical simulations of the deicing of composite aircraft components by electrothermal heating have been performed in a 2-D rectangular geometry. Seven numerical schemes and four solution methods were used to find the most efficient numerical procedure for this problem. The phase change in the ice was simulated using the Enthalpy method along with the Method for Assumed States. Numerical solutions illustrating deicer performance for various conditions are presented. Comparisons are made with previous numerical models and with experimental data. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Deicer↗

A numerical simulation of the full two-dimensional electrothermal de-icer pad

The ability to predict the time-temperature history of electrothermal de-icer pads is important in the subsequent design of improved and more efficient versions. These de-icer pads are installed near the surface of aircraft components, for the specific purpose of removing accreted ice. The proposed numerical model can incorporate the full 2-D geometry through a section of a region (i.e., section of an airfoil), that current 1-D numerical codes are unable to do. Thus, the effects of irregular layers, curvature, etc., can now be accounted for in the thermal transients. Each layer in the actual geometry is mapped via a body-fitted coordinate transformation into uniform, rectangular computational grids. The relevant heat transfer equations are transformed and discretized. To model the phase change that might occur in any accreted ice, in an enthalpy formulation the phase change equations are likewise transformed and discretized. The code developed was tested against numerous classical numerical solutions, as well as against experimental de-icing data on a UH1H rotor blade obtained from the NASA Lewis Research Center. The excellent comparisons obtained show that this code can be a useful tool in predicting the performance of current de-icer models, as well as in the designing of future models.

Masiulaniec, Konstanty C.↗

Nonlinear electrical transport near the metal–insulator transition in V 4 O 7 thin films

Nonlinear electrical transport associated with correlated electronic states has been widely investigated in transition-metal oxides near metal–insulator transitions. Here, in this study, we investigate nonlinear transport and threshold switching in sputter-deposited V 4 O 7 thin films grown on fused silica substrates. Temperature-dependent transport measurements show a metal–insulator transition near 240 K with negligible thermal hysteresis, defining the temperature scale that governs the nonlinear electrical response. Current–voltage measurements reveal reproducible bipolar threshold switching over a broad temperature range, with the threshold voltage decreasing systematically as the transition temperature is approached. Electrothermal finite-element simulations reproduce the measured switching characteristics and show that switching occurs when localized Joule heating drives a confined region of the device toward the transition temperature. The simulated peak local temperature at threshold lies close to the intrinsic metal–insulator transition temperature of V 4 O 7 , establishing that the nonlinear electrical response originates from electrothermal feedback acting on the strongly temperature-dependent conductivity near the transition. These results identify V 4 O 7 thin films as a model correlated-oxide system in which volatile threshold switching emerges from proximity to an extended metal–insulator transition.

25 ENERGY STORAGE↗

Effect of surface roughness on phase transition timing in megaampere pulsed-power–driven exploding conductors

An understanding of material phase transitions in megaampere pulsed-power–driven exploding conductors is important for predicting the growth of hydrodynamic instabilities in magneto-inertial fusion concepts. Here, this study analyzes phase transitions in electrical conductor explosions using 1D Lagrangian and 2D arbitrary Lagrangian–Eulerian resistive magnetohydrodynamic simulations to show that micrometer-scale surface roughness can lead to the electrothermal instability (ETI), a feedback effect that concentrates resistive heating and leads to early melting and ablation. Simulations of the Mykonos electrothermal instability II (METI-II) experiment show melting begins 19% sooner for machined rods with micrometer-scale surface roughness than for rods without these features. The surface magnetic field is 41 T around the initial region of melt, representing a lower magnitude than both the 86 T from 1D simulations and the 85 T threshold reported elsewhere. In 2D simulations with micrometer-scale surface roughness, temperature measurements indicate the critical point temperature of aluminum is reached 17% faster in comparison with 1D simulations. Values from 2D simulations with surface roughness align with predictions from ETI theory, and the observed temperature redistribution further supports the ETI as an underlying mechanism. Simulation results are validated against experimental photonic Doppler velocimetry data. This study shows 1D simulations are adequate to model conductors with sub-micrometer-scale surface roughness in this high-energy-density regime; however, 2D or 3D simulations are required to capture the full range of physics for accurately describing phase transitions in conductors with micrometer-scale or larger surface roughness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytical and Experimental Characterization of a Linear-Array Thermopile Scanning Radiometer for Geo-Synchronous Earth Radiation Budget Applications

The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.

Sorensen, Ira J.↗

A numerical and experimental investigation of electrochemical aircraft deicing

This study was composed of three parts. The first part involved the extension of an existing transient two dimensional numerical code for an electrothermal deicer so that it would simulate the situation where a variable thickness ice layer existed at the outer surface. The Enthalpy Method was used to simulate the phase change, and Gauss-Seidel iteration was used to solve the resulting system of finite difference equations. A set of criteria were developed for determining when a variable thickness ice layer had an effect on deicer performance. The second part was the acquisition and analysis of experimental data. The test model was a section of a Bell UH-1H helicopter blade equipped with an electrothermal deicer. A total of fifty-two thermocouples were utilized to document the thermal response of the blade and decier assembly. In the deicing runs, the experimental temperature response data clearly showed when melting, shedding or refreezing occurred. The tests illustrated that the criterion for shedding in the three cases where it did occur was that the abrasion shield interface temperature was 32 to 34 F. The third part concerned the validation of a one dimensional transient thermal model of an electrothermal deicer by comparison of the predictions with the experimental data. The Enthalpy Method was found to effectively model the phase change which occurred, and the ice shedding algorithm employed in the simulation was also evaluated.

Leffel, K. L.↗