Search NASA⌕ Search

SEARCH · Search NASA

Results for “elevated temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Room Temperature and Elevated Temperature Composite Sandwich Joint Testing

Testing of composite sandwich joint elements has been completed to verify the strength capacity of joints designed to carry specified running loads representative of a high speed civil transport wing. Static tension testing at both room and an elevated temperature of 350 F and fatigue testing at room temperature were conducted to determine strength capacity, fatigue life, and failure modes. Static tension test results yielded failure loads above the design loads for the room temperature tests, confirming the ability of the joint concepts tested to carry their design loads. However, strength reductions as large as 30% were observed at the elevated test temperature, where all failure loads were below the room temperature design loads for the specific joint designs tested. Fatigue testing resulted in lower than predicted fatigue lives.

Walker, Sandra P.↗

Elevated-Temperature "Ultra" Fast Fracture Strength of Advanced Ceramics: An Approach to Elevated-Temperature "Inert" Strength

The determination of "ultra" fast fracture strengths of five silicon nitride ceramics at elevated temperatures has been made by using constant stress-rate ("dynamic fatigue") testing with a series of "ultra" fast test rates. The test material included four monolithic and one SiC whisker-reinforced composite silicon nitrides. Of the five test materials, four silicon nitrides exhibited the elevated -temperature strengths that approaches their respective room-temperature strengths at an "ultra" fast test rate of 3.3 x 10(exp 4) MPa/s. This implies that slow cracks growth responsible for elevated-temperature failure can be eliminated or minimized by using the "ultra" fast test rate. These ongoing experimental results have shed light on laying a theoretical and practical foundation on the concept and definition of elevated-temperature "inert" strength behavior of advanced ceramics.

Choi, S. R.↗

The emittance of space radiator materials measured at elevated temperatures

The spectral emittances of textured space radiator materials between 1.7 and 14.7 micrometer have been evaluated at room temperature and elevated temperature (630 C) in air. Heating in air caused a permanent increase in spectral emittance for all materials tested: HCl/ion beam textured 304 stainless steel, untextured Ti (6 percent Al, 4 percent V), and sandblasted Ti (6 percent Al, 4 percent V). Changes in the surface chemistry and/or surface morphology of these materials were also observed. Elevated temperature spectral emittance was measured in an argon atmosphere and compared to the measurements in air. Similarity between the room temperature and elevated temperature spectral emittance measurements was also investigated, and limited agreement was found.

Mirtich, Michael J.↗

Evaluation of a strain-gage load calibration on a low-aspect-ratio wing structure at elevated temperature

The environmental aspect of elevated temperature and its relationship to the science of strain gage calibrations of aircraft structures are addressed. A section of a wing designed for a high-speed aircraft structure was used to study this problem. This structure was instrumented with strain gages calibrated at both elevated and room temperatures. Load equations derived from a high-temperature load calibration were compared with equations derived from an identical load calibration at room temperature. The implications of the high temperature load calibration were studied from the viewpoint of applicability and necessity. Load equations derived from the room temperature load calibration resulted in generally lower equation standard errors than equations derived from the elevated temperature load calibration. A distributed load was applied to the structure at elevated temperature and strain gage outputs were measured. This applied load was then calculated using equations derived from both the room temperature and elevated temperature calibration data. It was found that no significant differences between the two equation systems existed in terms of computing this applied distributed load, as long as the thermal shifts resulting from thermal stresses could be identified. This identification requires a heating of the structure. Therefore, it is concluded that for this structure, a high temperature load calibration is not required. However, a heating of the structure is required to determine thermal shifts.

Reardon, Lawrence F.↗

Fatigue of Ni-Al-Mo aligned eutectics at elevated temperatures

The elevated-temperature mechanical behavior of two aligned eutectics (Ni-8.1 wt % Al-26.4 wt % Mo and Ni-6.3 wt % Al-31.2 wt % Mo) has been investigated utilizing monotonic and cyclic testing in vacuum. Tensile yield strength and fatigue resistance increased from 25 to 725 C, but then were reduced at 825 C. The fatigue lives of specimens tested at 725 C decreased sharply with decreasing frequency. A shift from surface to internal crack initiation was observed upon increasing the test temperature from 725 to 825 C. Stage II crack propagation was observed at both temperatures, in contrast to stage I cracking at 25 C. The test results are compared to those for other nickel and cobalt-base aligned eutectics to show that the frequency effect on fatigue life is not limited to the Ni-Al-Mo system.

Tartaglia, J. M.↗

Elevated temperature envelope forming

Elevated temperature envelope forming includes enclosing a part blank and form tool within an envelope sealed against the atmosphere, heat treating the combination while forming pressure holds the envelope and part against the form tool, and allowing part cool down to occur in an inert atmosphere with forming pressure removed. The forming pressure is provided by evacuating the envelope and may be aided by differential force applied between the envelope and the form tool.

Burg, Bruce M.↗

Preliminary investigation of the compressive strength and creep lifetime of 2024-T3 (formerly 24S-T3) aluminum-alloy plates at elevated temperatures

The results of elevated-temperature compressive strength and creep tests of 2024-T3 (formerly 23S-T3) aluminum-alloy plates supported in V-grooves are presented. For determining elevated-temperature strength, where creep effects are negligible, a relation previously developed for predicting plate compressive strength at room temperature was satisfactory. Creep-lifetime results are presented for the plates in the form of master creep-lifetime curves by using a time-temperature parameter that is convenient for summarizing tensile creep-rupture data. A comparison is made between tensile and compressive creep lifetime for the plates, and the magnitude by which the design stress is decreased because of material creep and loss of strength due to exposure at elevated temperatures is indicated.

Mathauser, Eldon E↗

Directionally Solidified NiAl-Based Alloys Studied for Improved Elevated-Temperature Strength and Room-Temperature Fracture Toughness

Efforts are underway to replace superalloys used in the hot sections of gas turbine engines with materials possessing better mechanical and physical properties. Alloys based on the intermetallic NiAl have demonstrated potential; however, they generally suffer from low fracture resistance (toughness) at room temperature and from poor strength at elevated temperatures. Directional solidification of NiAl alloyed with both Cr and Mo has yielded materials with useful toughness and elevated-temperature strength values. The intermetallic alloy NiAl has been proposed as an advanced material to extend the maximum operational temperature of gas turbine engines by several hundred degrees centigrade. This intermetallic alloy displays a lower density (approximately 30-percent less) and a higher thermal conductivity (4 to 8 times greater) than conventional superalloys as well as good high-temperature oxidation resistance. Unfortunately, unalloyed NiAl has poor elevated temperature strength (approximately 50 MPa at 1027 C) and low room-temperature fracture toughness (about 5 MPa). Directionally solidified NiAl eutectic alloys are known to possess a combination of high elevated-temperature strength and good room-temperature fracture toughness. Research has demonstrated that a NiAl matrix containing a uniform distribution of very thin Cr plates alloyed with Mo possessed both increased fracture toughness and elevated-temperature creep strength. Although attractive properties were obtained, these alloys were formed at low growth rates (greater than 19 mm/hr), which are considered to be economically unviable. Hence, an investigation was warranted of the strength and toughness behavior of NiAl-(Cr,Mo) directionally solidified at faster growth rates. If the mechanical properties did not deteriorate with increased growth rates, directional solidification could offer an economical means to produce NiAl-based alloys commercially for gas turbine engines. An investigation at the NASA Glenn Research Center at Lewis Field was undertaken to study the effect of the directional solidification growth rate on the microstructure, room temperature fracture toughness, and strength at 1027 C of a Ni-33Al-31Cr-3Mo eutectic alloy. The directionally solidified rates varied between 7.6 and 508 millimeters per hour Essentially fault-free, alternating (Cr, Mo)/NiAl lamellar plate microstructures (left photograph) were formed during growth at and below 12.7 mm/hr, whereas cellular microstructures (right photograph) with the (Cr, Mo) phase in a radial spokelike pattern were developed at faster growth rates. The compressive strength at 1027 C continuously increased with increasing growth rate and did not indicate a maxima as was reported for directionally solidified Ni-33Al-34Cr. Surprisingly, samples with the lamellar plate microstructure (left photograph) possessed a room-temperature fracture toughness of approximately 12 MPa(sup square root of m), whereas all the alloys with a cellular microstructure had a toughness of about 17 MPa(sup square root of m). These results are significant since they clearly demonstrate that Ni-33Al-31Cr-3Mo can be directionally solidified at much faster growth rates without any observable deterioration in its mechanical properties. Thus, the potential to produce strong, tough NiAl-based eutectics at commercially acceptable growth rates exists. Additional testing and alloy optimization studies are underway.

Whittenberger, J. Daniel↗

Investigation of the Compressive Strength and Creep Lifetime of 2024-T3 Aluminum-Alloy Plates at Elevated Temperatures

The results of elevated-temperature compressive strength and creep tests of 2024-t3 (formerly 24s-t3) aluminum alloy plates supported in v-grooves are presented. The strength-test results indicate that a relation previously developed for predicting plate compressive strength for plates of all materials at room temperature is also satisfactory for determining elevated-temperature strength. Creep-lifetime results are presented for plates in the form of master creep-lifetime curves by using a time-temperature parameter that is convenient for summarizing tensile creep-rupture data. A comparison is made between tensile and compressive creep lifetime for the plates and a method that made use of isochronous stress-strain curves for predicting plate-creep failure stresses is investigated.

Mathauser, Eldon E↗

Ultra-Fast Fracture Strength of Advanced Ceramics at Elevated Temperatures

An attempt was made to determine elevated-temperature, 'ultra'-fast fracture strengths of one alumina, two silicon nitrides and one silicon carbide by using constant stress-rate ('dynamic fatigue') testing with a series of 'ultra'-fast test rates. Of the materials tested, the alumina exhibited a convergence of strength at stress rates below 3.3 x 10(exp 4) MPa/s. The strength approached approximately the room-temperature inert strength. By contrast, the silicon nitrides and silicon carbide did not reveal a strength approach, but exhibited elevated-temperature strengths 10 and 20% lower than their respective room-temperature strengths. Although the analytical results imply that the elevated-temperature 'inert' strength of a ceramic material can be obtained by using sufficiently high stress rates, the experimental testing rates were only sufficient to demonstrate convergence for the alumina.

Choi, Sung R.↗

Methods for structural design at elevated temperatures

A procedure which can be used to design elevated temperature structures is discussed. The desired goal is to have the same confidence in the structural integrity at elevated temperature as the factor of safety gives on mechanical loads at room temperature. Methods of design and analysis for creep, creep rupture, and creep buckling are presented. Example problems are included to illustrate the analytical methods. Creep data for some common structural materials are presented. Appendix B is description, user's manual, and listing for the creep analysis program. The program predicts time to a given creep or to creep rupture for a material subjected to a specified stress-temperature-time spectrum. Fatigue at elevated temperature is discussed. Methods of analysis for high stress-low cycle fatigue, fatigue below the creep range, and fatigue in the creep range are included. The interaction of thermal fatigue and mechanical loads is considered, and a detailed approach to fatigue analysis is given for structures operating below the creep range.

Ellison, A. M.↗

Effects of Long-Term Thermal Exposure on Commercially Pure Titanium Grade 2 Elevated-Temperature Tensile Properties

Elevated-temperature tensile testing of commercially pure titanium (CP Ti) Grade 2 was conducted for as-received commercially produced sheet and following thermal exposure at 550 and 650 K (531 and 711 F) for times up to 5000 h. The tensile testing revealed some statistical differences between the 11 thermal treatments, but most thermal treatments were statistically equivalent. Previous data from room temperature tensile testing was combined with the new data to allow regression and development of mathematical models relating tensile properties to temperature and thermal exposure. The results indicate that thermal exposure temperature has a very small effect, whereas the thermal exposure duration has no statistically significant effects on the tensile properties. These results indicate that CP Ti Grade 2 will be thermally stable and suitable for long-duration space missions.

Ellis, David L.↗

Elevated temperature deformation of TD-nickel.

Sensitivity of the elevated temperature (above 0.5 Tm) deformation of TD-nickel to grain size and shape was examined in both tension and creep. Elevated temperature strength increased with increasing grain diameter and increasing L/D ratio. Temperature sensitivity of the yield stress, as well as high (compared to self diffusion) apparent tensile activation enthalpies were the result of the internal stress not being proportional to the shear modulus. Creep activation enthalpies increased with increasing L/D ratio and, to a lesser extent, increasing grain diameter, reaching high values which may be apparent values. The thoria particle dispersion may have been altered by elevated temperature tensile and creep deformation.

Petrovic, J. J.↗

Behavior of composite bolted joints at elevated temperature

Experimental results from an investigation which examines the combined effects of temperature, joint geometry and out-of-plane constraint upon the response of mechanically fastened composite joints are presented. Data are presented for simulated mechanically fastened joint conditions in two laminate configurations fabricated from Hercules AS/3501-6 graphite-epoxy. Strength and failure mode results are presented for the test temperatures of 21 C, 121 C and 177 C and for a range of the geometric parameters W/D and e/D from 3.71 to 7.43 and 1.85 to 3.69, respectively. A hole diameter, D of 5.16 mm was utilized for all tests. Pin bearing tests with out-of-plane constraint were conducted at room temperature only. All elevated temperature data were generated for pin bearing conditions. Ultrasonic C scan inspection of the failed specimens was employed to assess the damage region and to determine failure mode. Comparative data are presented for pin bearing and out-of-plane constraint conditions for the above mentioned joint configurations. The joint under pin loading was modeled by two dimensional finite element methods. Predicted net section strain concentrations were compared with experimental results.

Wilson, D. W.↗