Search NASASearch

SEARCH · Search NASA

Results for “emission tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stimulated emission tomography for efficient characterization of spatial entanglement

Stimulated-emission tomography (SET) is an excellent tool for characterizing the process of spontaneous parametric down conversion (SPDC), which is commonly used to create pairs of entangled photons for use in quantum information protocols. The use of stimulated emission increases the average number of detected photons by several orders of magnitude compared to the spontaneous process. In a SET measurement, the parametric down conversion is seeded by an intense signal field prepared with specified mode properties rather than by broadband multimodal vacuum fluctuations, as is the case for the spontaneous process. The SET process generates an intense idler field in a mode that is the complex conjugate to the signal mode. In this work we use SET to estimate the joint spatial mode distribution (JSMD) in the Laguerre-Gaussian (LG) basis of the two photons of an entangled photon pair. The pair is produced by parametric down conversion in a beta barium borate (BBO) crystal with type-II phase matching pumped at a wavelength of 405 nm along with a 780 nm seed signal beam prepared in a variety of LG modes to generate an 842 nm idler beam of which the spatial mode distribution is measured. We observe strong idler production and good agreement with the theoretical prediction of its spatial mode distribution. Our experimental procedure should enable the efficient determination of the photon-pair wavefunctions produced by low-brightness SPDC sources and the characterization of high-dimensional entangled-photon pairs. Published by the American Physical Society 2024

Xu, Yang (ORCID:0009000954547320)

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Preliminary results from on going simulations and analyses will be presented.

Bruggemann, Jeremy

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology

Fan Beam Emission Tomography for Laminar Fires

Obtaining information on the instantaneous structure of turbulent and transient flames is important in a wide variety of applications such as fire safety, pollution reduction, flame spread studies, and model validation. Durao et al. has reviewed the different methods of obtaining structure information in reacting flows. These include Tunable Laser Absorption Spectroscopy, Fourier Transform Infrared Spectroscopy, and Emission Spectroscopy to mention a few. Most flames emit significant radiation signatures that are used in various applications such as fire detection, light-off detection, flame diagnostics, etc. Radiation signatures can be utilized to maximum advantage for determining structural information in turbulent flows. Emission spectroscopy is most advantageous in the infrared regions of the spectra, principally because these emission lines arise from transitions in the fundamental bands of stable species such as CO2 and H2O. Based on the above, the objective of this work was to develop a fan beam emission tomography system to obtain the local scalar properties such as temperature and mole fractions of major gas species from path integrated multi-wavelength infrared radiation measurements.

Sivathanu, Yudaya

Fan Beam Emission Tomography for Estimating Scalar Properties in Laminar Flames

A new method of estimating temperatures and gas species concentrations (CO2 and H2O) in a laminar flame is reported. The path-integrated, spectral radiation intensities emitted from a laminar flame at multiple wavelengths and view angles are calculated using a narrow band radiation model. Synthetic data, in the form of radial profiles of temperature and gas concentrations, are used in these calculations. The calculations mimic measurements that would theoretically be obtained using a mid-infrared spectrometer with a scanner. The path integrated spectral radiation intensities are deconvoluted using a maximum likelihood estimation method in conjunction with an iterative scheme. The deconvolution algorithm accounts for the self-absorption of radiation by the intervening gases, and provides the local temperature and gas species concentrations. The deconvoluted temperatures and gas concentrations are compared with the synthetic data used for calculating the spectral radiation intensities. The deconvoluted temperatures and gas species concentrations are within 0.5 % of the synthetic data. The deconvolution algorithm is expected to provide combustion researchers with an easy method of obtaining the radial profiles of major gas species concentrations and temperatures in laminar flames non-intrusively using a mid-infrared spectrometer with a scanner.

Lim, Jongmook

Fan Beam Emission Tomography Demonstrated Successfully in the Reduced-Gravity Environment of Drop Towers

Fires onboard manned spacecraft and launch vehicles are a particularly feared hazard because one cannot jump ship while in orbit 240 nmi above the Earth at 17 000 mph! Understanding the physical properties of fires in free fall and on orbit is, therefore, a very important endeavor for NASA s Human Exploration and Development of Space (HEDS) enterprise. However, detailed information concerning the structure of microgravity fires remained elusive until recently since robustness, limited power, limited volume, and limited mass place severe constraints on diagnostic equipment for use in space and in NASA Glenn Research Center s reduced-gravity facilities. Under NASA Research Associate funding since 2001, En'Urga, Inc. (Dr. Sivathanu, principal investigator, and Dr. Lim, co-investigator) in collaboration with Glenn (Dr. Feikema, coinvestigator) have successfully demonstrated a new technology for use in microgravity combustion. A midinfrared scanning spectrometer has been developed by En'Urga and tested at Glenn to measure 30 spectra per second at different spatial locations in a flame from 1.8 to 4.8 microns.

Feikema, Douglas A.

An atlas of Doppler emission-line tomography of cataclysmic variable stars

Doppler emission-line tomography is a technique similar to medical tomography. In this atlas the emission-line profiles of cataclysmic variable stars, seen at different orbital phases, are transformed into velocity space images. This transformation makes many of the complex line profile changes easier to interpret. The emission contributions of the disk and the s-wave are clearly separated in these images, and any emission from the stream and the secondary star can often be identified. In this atlas, Doppler tomograms of Hbeta, He I lambda 4471, and He II lambda 4686 emission lines of 18 cataclysmic variable stars are presented. The Doppler images provide insights into the individual systems and a better technique for measuring and radial velocity amplitude of the white dwarf.

Kaitchuck, Ronald H.

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Segmenting Images for a Better Diagnosis

NASA's Hierarchical Segmentation (HSEG) software has been adapted by Bartron Medical Imaging, LLC, for use in segmentation feature extraction, pattern recognition, and classification of medical images. Bartron acquired licenses from NASA Goddard Space Flight Center for application of the HSEG concept to medical imaging, from the California Institute of Technology/Jet Propulsion Laboratory to incorporate pattern-matching software, and from Kennedy Space Center for data-mining and edge-detection programs. The Med-Seg[TM] united developed by Bartron provides improved diagnoses for a wide range of medical images, including computed tomography scans, positron emission tomography scans, magnetic resonance imaging, ultrasound, digitized Z-ray, digitized mammography, dental X-ray, soft tissue analysis, and moving object analysis. It also can be used in analysis of soft-tissue slides. Bartron's future plans include the application of HSEG technology to drug development. NASA is advancing it's HSEG software to learn more about the Earth's magnetosphere.

Source record

Production of Medically Desirable Radioisotopes in the EIRENE Molten Salt Reactor

Radioisotopes play a vital role in nuclear medicine, enabling the performance of diagnostic procedures such as Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT), in addition to innovative targeted therapies for selectively delivering cytotoxic radiation doses to tumor cells while minimizing damage to healthy tissue [1]. Beta emitting radionuclides such as 90Y and 131I find wide use in radio-immunotherapy, with the radiopharmaceuticals 90Y-ibritumomab tiuxetan (Zevalin®) and 131I-tositumomab (Bexxar®) having received FDA approval for treatment of non-Hodgkin’s lymphoma through targeting the CD20 surface receptor, which is commonly expressed in many B cell non-Hodgkin’s lymphoma subtypes [2, 3]. 90Y has also been successfully applied for treatment of brain tumors [4, 5] and liver cancer [6]. The favorable chelation chemistry of 90Y enables its use with a variety of ligands for the development of radiopharmaceuticals suitable for targeting different carcinoma types [1].

42 - ENGINEERING

Positron emission reconstruction tomography for the assessment of regional myocardial metabolism by the administration of substrates labeled with cyclotron produced radionuclides

A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.

Ter-Pogossian, M. M.

Baroreflex regulation of blood pressure during dynamic exercise

From the work of Potts et al. Papelier et al. and Shi et al. it is readily apparent that the arterial (aortic and carotid) baroreflexes are reset to function at the prevailing ABP of exercise. The blood pressure of exercise is the result of the hemodynamic (cardiac output and TPR) responses, which appear to be regulated by two redundant neural control systems, "Central Command" and the "exercise pressor reflex". Central Command is a feed-forward neural control system that operates in parallel with the neural regulation of the locomotor system and appears to establish the hemodynamic response to exercise. Within the central nervous system it appears that the HLR may be the operational site for Central Command. Specific neural sites within the HLR have been demonstrated in animals to be active during exercise. With the advent of positron emission tomography (PET) and single-photon emission computed tomography (SPECT), the anatomical areas of the human brain related to Central Command are being mapped. It also appears that the Nucleus Tractus Solitarius and the ventrolateral medulla may serve as an integrating site as they receive neural information from the working muscles via the group III/IV muscle afferents as well as from higher brain centers. This anatomical site within the CNS is now the focus of many investigations in which arterial baroreflex function, Central Command and the "exercise pressor reflex" appear to demonstrate inhibitory or facilitatory interaction. The concept of whether Central Command is the prime mover in the resetting of the arterial baroreceptors to function at the exercising ABP or whether the resetting is an integration of the "exercise pressor reflex" information with that of Central Command is now under intense investigation. However, it would be justified to conclude, from the data of Bevegard and Shepherd, Dicarlo and Bishop, Potts et al., and Papelier et al. that the act of exercise results in the resetting of the arterial baroreflex. In addition, if, as we have proposed, the cardiopulmonary baroreceptors primarily monitors and reflexly regulates cardiac filling volume, it would seem from the data of Mack et al. and Potts et al. that the cardiopulmonary baroreceptor is also reset at the beginning of exercise. Therefore, investigations of the neural mechanisms of regulation involving Central Command and cardiopulmonary afferents, similar to those being undertaken for the arterial baroreflex, need to be established.

NASA Discipline Cardiopulmonary

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING

Plasma GFAP for populational enrichment of clinical trials in preclinical Alzheimer's disease

Abstract INTRODUCTION Cognitively unimpaired (CU) amyloid beta (Aβ)+ individuals with elevated plasma glial fibrillary acidic protein (GFAP) have an increased risk of Alzheimer's disease (AD)‐related progression. We tested the utility of plasma GFAP for population enrichment CU populations in clinical trials. METHODS We estimated longitudinal progression, effect size, and costs of hypothetical clinical trials designed to test an estimated 25% drug effect on reducing tau positron emission tomography (PET) accumulation in the medial temporal lobe (MTL) and temporal neocortical region (NEO‐T). RESULTS CU GFAP+/Aβ+ individuals present an increased annual rate of change and effect size in tau PET MTL and tau PET NEO‐T compared to the other groups. An enrichment strategy selecting CU GFAP+/Aβ+ individuals would require a smaller sample size (≈ 57% reduction) and fewer Aβ PET scans (≈ 74% reduction) than trials enriched with Aβ PET alone, reducing total clinical trial costs by up to 64%. DISCUSSION Our results suggest that clinical trials focusing on preclinical AD recruiting Aβ+ individuals with elevated GFAP levels would improve cost effectiveness. Highlights Cognitively unimpaired (CU) glial fibrillary acidic protein (GFAP)+/amyloid beta (Aβ)+ shows increased changes in tau positron emission tomography (PET) . CU GFAP+/Aβ+ enriched clinical trials require a reduced sample size compared to Aβ+ only. CU GFAP+/Aβ+ enrichment reduces Aβ PET scans required and costs. CU GFAP+/Aβ+ enrichment allows the selection of individuals at early stages of the Alzheimer's disease continuum.

Neurosciences & Neurology