Search NASA⌕ Search

SEARCH · Search NASA

Results for “emittance evolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Studies of Beam Intensity Effects in Fermilab Booster Synchrotron. Part II: Beam Emittance Evolution

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV Fermilab Booster. Here we report the results of comprehensive studies of various beam intensity dependent effects in the Booster. In the previous publication we presented the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. Here we discuss two methods of the Booster beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors), analyze the intensity dependent emittance growth effects and discuss the ultimate performance of the machine now and after foreseen and proposed upgrades.

43 PARTICLE ACCELERATORS↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in g4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages of this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, Michael A. [Fermilab] (ORCID:0009000557↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization profile monitors for the IOTA proton beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors — one vertical and one horizontal — are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. Furthermore, in this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

Beam diagnostics↗

Simulating Magnetized Electron Cooling for EIC with JSPEC

We present a possible electron cooling configuration for the proposed Electron Ion Collider (EIC) facility, developed using a Nelder-Mead Simplex optimization procedure built into JSPEC, an electron cooling code developed at Jefferson Lab. We show the time evolution of the emittance of the ion beam in the presence of this cooler evaluated assuming the ion distribution remains Gaussian. We also show that bi-gaussian distributions emerge in simulations of ion macro-particles. We show how intra-beam scattering can be treated with a core-tail model in simulations of ion macro-particles. The Sirepo/JSPEC* and Sirepo/Jupyter** apps will be presented, with instructions enabling the community to reproduce our simulations.

Coleman, S. J.↗

Measured dynamic aperture and detuning of nonlinear integrable optics

One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.

43 PARTICLE ACCELERATORS↗

Measured Dynamic Aperture and Detuning of Nonlinear Integrable Optics

One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.

43 PARTICLE ACCELERATORS↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

3D Tracking of a Single Electron in IOTA

High-resolution observations of single-particle dynamics have potential as a powerful tool in the diagnostics, tuning and design of storage rings. We are presenting the results of experiments with single electrons that were conducted at Fermilab’s IOTA ring to explore the feasibility of this approach. A set of sensitive, high-resolution digital cameras was used to detect the synchrotron radiation emitted by an electron, and the resulting images were used to reconstruct the time evolution of oscillation amplitudes in all three degrees of freedom. From the evolution of the oscillation amplitudes, we deduce transverse emittances, momentum spread, damping times, beam energy and estimated residual-gas density and composition. To our knowledge, this is the first time that the dynamics of a single particle in a storage ring has been tracked in all three dimensions. We discuss farther development of a single particle diagnostics that may allow reconstruction of its turn-by-turn coordinates over macroscopic periods of time facilitating ultra-precise lattice diagnostics and direct benchmarking of tracking codes.

43 PARTICLE ACCELERATORS↗

Beyond RMS: Understanding the Evolution of Beam Distributions in High Intensity Linacs

Understanding the evolution of beams with space charge is crucial to design and operation of high intensity linacs. While the community holds a broad understanding of the mechanisms leading to emittance growth and halo formation, there is outstanding discrepancy between measurements and beam evolution models that precludes prediction of halo losses. This may be due in part to insufficient information of the initial beam distribution. This talk will describe work at the SNS Beam Test Facility to directly measure the 6D beam distribution. Full-and-direct 6D measurement has revealed hidden but physically significant dependence between the longitudinal distribution and transverse coordinates. This nonlinear correlation is driven by space charge and reproduced by self-consistent simulation of the RFQ. Omission of this interplane correlation, common when bunches are reconstructed from lower-dimensional measurements, degrades downstream predictions. This talk will also describe the novel diagnostics supporting this work. This includes ongoing improvements to efficiency of the 6D phase space measurement as well as recent achievement of six orders of dynamic range in 2D phase space.

Ruisard, Kiersten↗

Effect of emitters on quantum state transfer in coupled cavity arrays

Over the last decade, conditions for perfect state transfer in quantum spin chains have been discovered and their experimental realizations addressed, as have their extensions to more complex geometries of coupled cavity-emitter arrays. In this paper we further consider such studies and situations in which quantum state transfer can occur with high fidelity, even when the cavity-cavity coupling rates and cavity-emitter interaction rates are comparable. This is accomplished through the development and use of a Monte Carlo approach to the inverse eigenvalue problem, which allows the determination of coupling rates which optimize quantum state transfer fidelity and subsequent time evolution of the polariton wave function through exact diagonalization of the resulting Jaynes-Cummings-Hubbard Hamiltonian. The effect of inhomogeneous emitter locations is also evaluated. Furthermore, our key results include the demonstration that our methodology can be used successfully to establish Hamiltonian parameters for high-fidelity state transfer in more general lattice geometries and excitation number sectors, and also a determination of the effects of fluctuations in those parameters about their optimal values.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Outside the Lyman-break box: detecting Lyman continuum emitters at 3.5 < z < 5.1 with CLAUDS

ABSTRACT Identifying non-contaminated sample of high-redshift galaxies with escaping Lyman continuum (LyC) flux is important for understanding the sources and evolution of cosmic reionization. We present CLAUDS (CFHT Large Area u-band deep survey) u-band photometry of the COSMOS field to probe LyC radiation from spectroscopically confirmed galaxies at $z$ ≥ 3.5 and outside the standard Lyman-break galaxy colour-selection expectations. Complementary to the CLAUDS data, we use Subaru multifilter photometry, Hubble Space Telescope (HST) multifilter imaging, and the spectroscopic surveys D10K, VUDS, and 3D-HST. We present a sample of Lyman continuum galaxy (LCG) candidates in the redshift range 3.5 ≲ $z$ ≲ 5.1. Here, we introduce 5 LCG candidates, where two are flagged quality 1 and three quality 2. The estimated $f_{\rm esc}^{\rm abs}$ for quality 1 candidates are in the range $\sim 5 - 73{{\ \rm per\ cent}}$ and $\sim 30 - 93{{\ \rm per\ cent}}$. These estimates are based on our derived parameters from individual galaxies as inputs to a range of BPASS models as well as mean intergalactic medium (IGM) and maximal intergalactic and circumgalactic media (IGM+CGM) transmission. We conclude that our search for LCGs is most likely biased to lines of sight with low H i densities or free from Lyman limit systems. Our two best LCG candidates have EW (Lyα) ≤ 50 Å and we find no correlation or anticorrelation between EW (Lyα), $f_{\rm esc}^{\rm abs}$, and Robs, the ratio of ionizing to non-ionizing observed flux in the measured passbands. Stacking candidates without solid LyC detections (S/N < 3) results in an estimated $f_{\rm esc}^{\rm abs}$ from galaxies not greater than $1{{\ \rm per\ cent}}$.

Meštrić, U.↗

Sudden collapse of a pressure profile generated by off-axis heating in a linear magnetized plasma

Here, the features of an unexpected, large event that arises spontaneously during a basic heat transport experiment are presented. It consists of the sudden collapse of the radial plasma pressure profile, akin to disruption events observed in toroidal magnetic confinement devices. The experiment is performed on the Large Plasma Device at the University of California, Los Angeles (UCLA). It uses a LaB6 thermionic emitter of annular shape to induce off-axis heating of a cold, afterglow plasma, in a linear magnetic geometry. The temporal evolution consists of three regimes. During an early, quiescent period, classical heat transport along and across the magnetic field arises from Coulomb collisions. After significant pressure gradients develop, drift-Alfvén waves become unstable. Upon reaching large amplitude, they trigger avalanche events that flatten the outer part of the heated region, which, in turn, quenches the instability. Due to the sustained heating, the pressure profile rebuilds and the process repeats, leading to a relatively long, second regime that displays multiple avalanches, but suddenly, the annular pressure profile is observed to collapse. After this collapse, the system enters a third regime with large fluctuations. Before the collapse, a rapid, runaway heating environment arises whose time evolution exhibits a self-similar dependence on the applied voltage. The time evolution, morphology, and scaling of the collapse event are presented, and an examination is made of the underlying mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

ODIN: Confirmation and 3D Reconstruction of Six Massive Protoclusters at Cosmic Noon

Protoclusters represent sites of accelerated galaxy formation and extreme astrophysical activity characteristic of dense environments. Identifying massive protoclusters and mapping their spatial structures are therefore crucial for understanding how large-scale environment influences galaxy evolution. We combine wide-field Lyα imaging from the One-hundred-deg$^{2}$ DECam Imaging in Narrowbands survey with extensive Dark Energy Spectroscopic Instrument and ancillary spectroscopy across the extended COSMOS and XMM Large Scale Structure (LSS) fields (≈14 deg$^{2}$) to search for massive protoclusters. We confirm six systems at z ≈ 2.4 and ≈ 3.1, including three newly identified structures and three which overlap with previously known structures and/or systems detected using other tracers. We reconstruct their three-dimensional structures, estimate descendant halo masses, and for one structure at z ≈ 3.12, demonstrate that overlapping narrowband filters (NB497 and N501) provide accurate redshift tomography for emission-line galaxies. One protocluster at z ≈ 2.45 overlaps with one of the LATIS tomographic fields, enabling direct comparison between galaxy and H i overdensities traced by Lyα forest absorption. Another at z ≈ 3.12 hosts a massive quiescent galaxy (M$_{*}$ ≈ 1.2 × 10$^{11}$M$_{⊙}$), suggesting that overdense environments may play a role in accelerating galaxy assembly and quenching. Comparing Lyα emission properties across environments, we find that protocluster galaxies exhibit higher median line fluxes and a deficit of faint emitters relative to the field. The effect is strongest when combining 2D and 3D density information, indicating that galaxies in the densest protocluster cores are most affected by environmental processes. This effect is stronger at z ≈ 3.1 than at z ≈ 2.4, suggesting possible redshift evolution.

Ortiz, Ashley [Purdue U.] (ORCID:000900083184304X)↗