Correlating and Simulating Socio-Demographically Driven Residential End-Use Activity Schedules

Incorporating socio-demographic and behavioral considerations into decision-support tools is crucial for identifying gaps and addressing consumer needs to ensure reliable and affordable energy solutions. In energy simulation models, the correlation between socio-demographics and time-use behavior is not well-captured. Thus, we developed a large-scale simulation workflow to generate schedules for 10 residential activities across 24 population segments defined by age, income, and employment status. Using pre-pandemic 2015-2019 American Time Use Survey (ATUS) data, we used ANOVA to confirm the correlation between demographic factors and time use. We explored three k-modes clustering methods-backward, forward, and a new hybrid approach-to delineate the occupancy patterns based on demographics. Using the probability of cluster membership for each population segment and a time inhomogeneous Markov chain to generate activity transition probabilities for each cluster, we simulated 50,000 schedules per segment and validated them against the ATUS data. The hybrid method produced the most socio-demographically differentiated clusters while demonstrating comparable performance to other approaches, with an overall root mean square error of 0.12 for both weekday and weekend schedules. Thus, the hybrid method, where each cluster is dominated by certain demographic segments and occupancy patterns, offers more modeling versatility in terms of scenario analysis. The new workflow improves the socio demographic differentiation of energy consumption by considering differences in time use. This approach enables future research on demographically segmented time of use (TOU) energy consumption, including impacts of TOU utility bills and rate analysis, long-run marginal emissions, and energy retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Buildings Sector Scenarios: Demand-side data to support energy system planning in the United States

The US energy system is in a period of high uncertainty about load growth, its implications for the energy generation mix, and downstream impacts on customer energy costs. In this context, there is a need for comprehensive, credible, and readily-customized projections of energy demand to ensure that planning decisions account for end-use management opportunities to improve system reliability and affordability. Here we introduce the Buildings Sector Scenarios (BSS) dataset, which includes a benchmark suite of such projections for the buildings sector — a key source of energy consumption, peak electricity demand, and consumer energy expenditures. The dataset contains projections through 2050 covering the contiguous United States (CONUS) resolved down to the county, hourly level by sector and end use for electricity demand and to the state, annual level by sector and end use for non-electric fuels. We summarize the BSS analysis workflow and the tools and datasets that support it, document key BSS scenario inputs and modeling assumptions, and outline BSS scenario outputs. We assess the technical quality of the dataset against historical surveys and projected estimates of buildings sector demand. Finally, we provide guidance on how stakeholders can access, use, and reproduce the dataset, and/or create new scenarios to explore their own analysis questions.

Langevin, Jared↗

Techno-Economic Analysis of Repurposing Natural Gas Transmission Pipeline Networks to Accommodate Hydrogen Blends

Blending hydrogen into natural gas infrastructure could supplement natural gas supply and increase resilience for applications such as ammonia production, peaking and load-following power plants, and heating. The United States has an extensive network of natural gas pipelines, but the feasibility of employing this infrastructure to transport hydrogen is unclear. We analyze the costs associated with repurposing three distinct natural gas transmission pipelines in different locations within the United States to carry blends of hydrogen up to 100% via three different pipeline network modification methods and compare against the cost of building a new dedicated hydrogen pipeline. We conduct a sensitivity analysis on the hoop stress limit of the existing pipe, techno-economic parameters, emissions, and relative capacity. The results show that the capital costs required to upgrade a pipeline can vary from tens of millions to billions of dollars depending on the length and capacity of the existing pipeline section, whether the existing pipeline already operates at or below its maximum allowable operating pressure, whether future demand is expected to increase or decrease, the network modification method selected, and pipe material costs. The delivered cost of energy to end users is impacted less by the levelized cost of transporting hydrogen blends than by the cost of the natural gas and hydrogen fuels being transported. The emissions impact of blending hydrogen into natural gas transmission networks scales proportionally with the amount of energy displaced with low-emission hydrogen (such as from natural gas with carbon capture and sequestration or electrolysis powered by nuclear, renewable, or geothermal electricity), therefore low blend ratios (e.g., < 20% vol. hydrogen) will result in low emissions impacts. Factors such as permitting and right-of-way costs, the proximity of the pipeline to hydrogen demand and production, and the compatibility of and/or retrofitting costs of end-use gas-fueled technologies will likely be greater drivers in determining whether converting a particular natural gas pipeline to carry hydrogen makes economic sense.

08 HYDROGEN↗

Decision Support System

Forest-based value chains involve decisions that begin at the landscape level and extend through processing, product manufacturing, and end-use markets. However, these decisions are often made independently across sectors, with limited visibility into how upstream resource conditions, incentives, and land management choices influence downstream production systems. In forested regions of the United States, wildfire risk, fragmented ownership, and uncertain markets for low-value residues complicate efforts to align extraction, processing, and utilization decisions. Without tools that link these stages, stakeholders may overlook opportunities to improve resource utilization or inadvertently shift impacts elsewhere in the value chain. This repository introduces a decision support system (DSS) that applies a system-impact-analysis approach to forest biomass residues and co-products. The framework integrates forest inventory data, geospatial resource assessments, and economic modeling to evaluate how biomass extraction decisions influence downstream product pathways. By linking regional feedstock avail- ability with market incentives and processing options—such as fuels, wood products, or soil amendments like biochar—the tool allows decision-makers to compare value chain outcomes across multiple utilization strategies.

Davis, Maggie [Oak Ridge National Laboratory (ORNL↗

OpenStudio®-MCP [SWR-26-035]

OpenStudio®-MCP is a Model Context Protocol (MCP) server that lets AI assistants perform building energy modeling through natural language. Rather than requiring users to learn the OpenStudio® SDK, EnergyPlus® scripting, or Ruby/Python automation, the server translates conversational requests into sequences of tool calls that create models, design HVAC systems, run simulations, and extract results — all within a single chat session. The server's 124 tools are organized into a skills architecture where each skill encapsulates a domain of building energy modeling (envelope, HVAC, loads, weather, simulation, results) behind typed, LLM-friendly interfaces. High-leverage operations like applying ASHRAE 90.1 baseline systems or generating standards-compliant typical buildings are exposed as single tool calls that internally wire dozens of OpenStudio® objects. Bundled measures from ComStock™ and Openstudio® -common-measures-gem are wrapped with dedicated tools and typed arguments rather than exposed through a generic measure interface, so AI models get consistent, error-resistant recipes without needing to discover measure arguments at runtime. A key design decision is structured results extraction: six SQL-based tools return surgical ~300–1,000 token responses (end-use breakdowns, envelope summaries, HVAC sizing, timeseries data) instead of requiring the AI to parse ~100K-token raw HTML reports, making iterative design exploration practical within context window limits. The codebase is designed as a reference implementation — explicit, well-commented, and modular — so that other simulation engines (EnergyPlus® standalone, TRNSYS, DOE-2) can use it as a template for building their own MCP servers.

Ball, Brian [National Laboratory of the Rockies (N↗

SERA: A Hydrogen Infrastructure Capacity Expansion Model

The Scenario Evaluation and Regionalization Analysis (SERA) model is an infrastructure planning optimization model that can guide hydrogen production, delivery, and end-use investment decisions and accelerate the adoption of low-cost hydrogen at scale, whether for fuel cell electric vehicles or non-transportation applications. In this talk, we will review the SERA model objective function as well as the data inputs and outputs. We will also look at a SERA case study identifying potential dispensed costs of hydrogen along major refueling corridors throughout the United States. In addition to the SERA model, Justin will also discuss his recent work for the Office of Manufacturing and Energy Supply Chains on electrolyzer supply chain readiness, and his work for the Hydrogen Fuel Cell Technologies Office and Environmental Protection Agency on the levelized cost of dispensed hydrogen for heavy-duty trucking.

30 DIRECT ENERGY CONVERSION↗

2024 Bioenergy Industry Status Report

This report provides a snapshot of the bioenergy industry status at the end of 2024. The report compliments other annual market reports from the Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) offices and is supported by DOE'sOffice of Critical Minerals and Energy Innovation's Alternative Fuels and Feedstocks Office. The 2024 Bioenergy Industry Status Report focuses on past year data covering multiple dimensions of the bioenergy industry and does not attempt to make future market projections. There report covers production, consumption, plants, trade, and end-use for all biofuels, biopower, and biobased products where data is available. The report provides a balanced and unbiased assessment of the industry and associated markets. It is openly available to the public and is intended to complement other industry reports with a focus on DOE stakeholder needs.

09 BIOMASS FUELS↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Production of Renewable Natural Gas from Waste Carbon Dioxide Sources (CRADA Final Report)

This CRADA provides new funding from SoCalGas and DOE's BETO and FCTO Offices focused hydrogen mass transfer limitations in H2@Scale processes. The project leverages the existing hydrogen production capabilities at the Energy Systems Integration Facility (ESIF) and SoCalGas' 700 L bioreactor system designed, built, and delivered to NLR under the first phase of this CRADA. This Joint Work Statement will cover new hardware modifications between NLR's electorlyzer stack and the SoCalGas bioreactor located outdoors. The new hardware and controls will provide researchers with the tools needed to obtain preliminary experimental data for a non-provisional application due in July 2019. The IP being developed is expected to improve the productivity of the bioreactor and would have wider impacts on other end-use processes using pressurized hydrogen (H2). In addition, this new funding enhances an existing BETO Biopower award by developing a 10-15 kW electrolyzer that is scalable to the MW-class with reduced capital cost and higher efficiency aimed at improving H2 mass transfer to downstream processes, like biomethanation. Finally due to the close-coupling between the electrolyzer stack and bioreactor, R&D will focus on cell retention, nutrient maintenance, optimal water management and process controls.

08 HYDROGEN↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.