Search NASA⌕ Search

SEARCH · Search NASA

Results for “endoscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery

The term Multi-Angle and Rear Viewing Endoscopic tooL (MARVEL) denotes an auxiliary endoscope, now undergoing development, that a surgeon would use in conjunction with a conventional endoscope to obtain additional perspective. The role of the MARVEL in endoscopic brain surgery would be similar to the role of a mouth mirror in dentistry. Such a tool is potentially useful for in-situ planetary geology applications for the close-up imaging of unexposed rock surfaces in cracks or those not in the direct line of sight. A conventional endoscope provides mostly a frontal view that is, a view along its longitudinal axis and, hence, along a straight line extending from an opening through which it is inserted. The MARVEL could be inserted through the same opening as that of the conventional endoscope, but could be adjusted to provide a view from almost any desired angle. The MARVEL camera image would be displayed, on the same monitor as that of the conventional endoscopic image, as an inset within the conventional endoscopic image. For example, while viewing a tumor from the front in the conventional endoscopic image, the surgeon could simultaneously view the tumor from the side or the rear in the MARVEL image, and could thereby gain additional visual cues that would aid in precise three-dimensional positioning of surgical tools to excise the tumor. Indeed, a side or rear view through the MARVEL could be essential in a case in which the object of surgical interest was not visible from the front. The conceptual design of the MARVEL exploits the surgeon s familiarity with endoscopic surgical tools. The MARVEL would include a miniature electronic camera and miniature radio transmitter mounted on the tip of a surgical tool derived from an endo-scissor (see figure). The inclusion of the radio transmitter would eliminate the need for wires, which could interfere with manipulation of this and other surgical tools. The handgrip of the tool would be connected to a linkage similar to that of an endo-scissor, but the linkage would be configured to enable adjustment of the camera angle instead of actuation of a scissor blade. It is envisioned that thicknesses of the tool shaft and the camera would be less than 4 mm, so that the camera-tipped tool could be swiftly inserted and withdrawn through a dime-size opening. Electronic cameras having dimensions of the order of millimeters are already commercially available, but their designs are not optimized for use in endoscopic brain surgery. The variety of potential endoscopic, thoracoscopic, and laparoscopic applications can be expected to increase as further development of electronic cameras yields further miniaturization and improvements in imaging performance.

Bae, Youngsam↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Design and fabrication of a stereoscopic rear-viewing endoscopic tool (MARVEL)

The use of minimally invasive neurosurgical techniques has experienced a growing interest among patients and surgeons alike due their the numerous advantages over more traditional operations. Current methods employ the use either rigid or articulating endoscopes, both of which are inserted through a small diameter opening in the skull near the intended surgical region. Although these devices aid the surgeon in viewing the operating site, they are severely limited by their inability to provide dimensional awareness to the user. The Multi-Angle Rear-Viewing Endoscopic TooL (MARVEL) has been designed such that the compact form of existing endoscopes is maintained while also providing the user with an enhanced 3-dimensional stereo view. The design of the alpha prototype for MARVEL was completed over the course of three months. In parallel with development, the device's optics were characterized and several software programs were generated. Once assembled, MARVEL will hold many advantages over existing endoscopic tools. It is expected that the device will greatly outperform its traditional counterparts by both increasing safety and decreasing the duration of surgical procedures. After completion, the device will be demonstrated to the project sponsors at the Skull Base Institute where it will undergo full evaluation and a feasibility analysis.

Strongrich, Andrew↗

Endoscopic surgery in weightlessness: the investigation of basic principles for surgery in space

BACKGROUND: Performing a surgical procedure in weightlessness, also called 0-gravity (0-g), has been shown to be no more difficult than in a 1-g environment if the requirements for the restraint of the patient, operator, surgical hardware, are observed. The performance of laparoscopic and thorascopic procedures in weightlessness, if feasible, would offer several advantages over the performance of an open operation. Concerns about the feasibility of performing minimally invasive procedures in weightlessness have included impaired visualization from the absence of gravitational retraction of the bowel (laparoscopy) or thoracic organs (thoracoscopy) as well as obstruction and interference from floating debris such as blood, pus, and irrigation fluid. The purpose of this study was to determine the feasibility of performing laparoscopic and thorascopic procedures and the degree of impaired surgical endoscopic visualization in weightlessness. METHODS: From 1993 to 2000, laparoscopic and thorascopic procedures were performed on 10 anesthetized adult pigs weighing approximately 50 kg in the National Aeronautics and Space Administration (NASA) Microgravity Program using a modified KC-135 airplane. The parabolic simulation system for advanced life support was used in this project, and 20 to 40 parabolas were used for laparoscopic or thorascopic investigation, each containing approximately 30 s of 0-g alternating with 2-g pullouts. The animal model was restrained in the supine position on a floor-level Crew Medical Restraint System, and the abdominal cavity was insufflated with carbon dioxide. The intraabdominal and intrathoracic anatomy was visualized in the 1-g, 0-g, and 2-g periods of parabolic flight. Bleeding was created in the animals, and the behavior of the blood in the abdominal and thoracic cavities was observed. In the thoracic cavity, gas insufflation and mechanical retraction was used at times unilaterally to decrease pulmonary ventilation enough to increase the thoracic domain. RESULTS: Visualization was improved in laparoscopy, from tethering of the bowel by the elastic mesentery, and from the strong tendency for debris and blood to adhere to the abdominal wall because of surface tension forces. The lack of adequate thoracic domain made thorascopy more difficult. Fluid in the thoracic cavity did not impair visualization because the fluid at 0-g does not loculate posteriorly, but disperses along the thoracic wall and mediastinal reflections. CONCLUSIONS: Performing minimally invasive procedures instead of open surgical procedures in a weightless environment has theoretical advantages, especially in the ability to prevent cabin atmosphere contamination from surgical fluids (blood, pus, irrigation). Visualization will become more important and practical as the endoscopic hardware is miniaturized from its current form, as endoscopic technology becomes more advanced, and as more surgically capable medical crew officers are present in future long-duration space exploration missions.

short duration↗

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

Apparatus for endoscopic examination

An endoscope is having a propulsion mechanism and at least one transmitter at the distal end transmitting bursts of energy waves (radio frequency or ultrasonic) for tracking the position of the distal end through the use of two or more transducers on the anterior or lateral surfaces of a patient is described. The propulsion mechanism which consists of two radially expandable bladders separated by an axially expandable bellows with only the forward bladder attached to the distal end is discussed. Alternate mechanisms are reported. A sheath on the endoscope which includes material having a sharp melting point slightly above body temperature so that the sheath is made flexible at selected sections by applying current to separate heating wires in the sections of the sheath is described.

Frazer, R. E.↗

Various Embodiments of the Non-Invasive Endoscopic Feedback for Learning of Voluntary Control of Physiological Functioning

The research performed was a small portion of the patent to be submitted by Dr. Alan T. Pope entitled 'A Method of Providing Veridical Non-Invasive Endoscopic Feedback for Learning of Voluntary Control of Physiological Functioning'. The focus of this study is to incorporate the emerging technology of virtual reality with the forms of biofeedback already in existance producing a life-like, real-time model of the body's functioning without using invasive procedures, yet still producing the equivalent of a picture from an invasive endoscopic procedure in the region of interest. The portion of the project designated to me was to research and report as many possible uses for such technology as possible.

Henriksen, Mina D.↗

Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

Parabolic Flight↗

High-Speed Generation of Illumination Spectra for a Stereoscopic Endoscope

Traditional stereoscopic vision (3D) is achieved through use of two separate cameras, arranged to emulate human eyes. This method works well on most projects, but becomes impractical on small scale designs, such as surgical endoscopes. This project is focused on developing a stereoscopic endoscope, using a single camera and Conjugated Multiple?Bandpass Filters (CMBF) to produce stereoscopic vision. Each half of filter is built to allow a distinct spectrum to pass through, while blocking the complimentary spectrum. A system with complimentary filters can produce stereoscopic images. To accomplish this, the light must be filtered at the source to match the filters at the camera. Additionally, the light source and camera must be synchronized in a way that each image will show only one filter spectrum. In this paper, I will describe the design and characterization of the prototype electro?optical system, including optical throughput measurements and video produced using this method.

Conjugated Multiple?Bandpass Filters (CMBF)↗

Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning

Epidural anesthesia requires injection of anesthetic into the epidural space in the spine. Accurate placement of the epidural needle is a major challenge. To address this, we developed a forward-view endoscopic optical coherence tomography (OCT) system for real-time imaging of the tissue in front of the needle tip during the puncture. We tested this OCT system in porcine backbones and developed a set of deep learning models to automatically process the imaging data for needle localization. A series of binary classification models were developed to recognize the five layers of the backbone, including fat, interspinous ligament, ligamentum flavum, epidural space, and spinal cord. The classification models provided an average classification accuracy of 96.65%. During puncture, it is important to maintain a safe distance between the needle tip and the dura mater. Regression models were developed to estimate that distance based on the OCT imaging data. Based on the Inception architecture, our models achieved a mean absolute percentage error of 3.05% ± 0.55%. Overall, our results validated the technical feasibility of using this novel imaging strategy to automatically recognize different tissue structures and measure the distances ahead of the needle tip during the epidural needle placement.

60 APPLIED LIFE SCIENCES↗

Endoscopic Shearography and Thermography Methods for Nondestructive Evaluation of Lined Pressure Vessels

The goal of this research effort was the development of methods for shearography and thermography inspection of coatings, bonds, or laminates inside rocket fuel or oxidizer tanks, fuel lines, and other closed structures. The endoscopic methods allow imaging and inspection inside cavities which are traditionally inaccessible with shearography or thermography cameras. The techniques are demonstrated and suggestions for practical application are made in this report. Drawings of the experimental setups, detailed procedures, and experimental data are included.

Lansing, Matthew D.↗

Endoscopic Shearography and Thermography Methods for Nondestructive Evaluation of Lined Pressure Vessels

The goal of this research effort was the development of methods for shearographic and thermographic inspection of coatings, bonds, or laminates inside rocket fuel or oxidizer tanks, fuel lines, and other closed structures. The endoscopic methods allow imaging and inspection inside cavities that are traditionally inaccessible with shearography or thermography cameras. The techniques are demonstrated and suggestions for practical application are made in this report. Drawings of the experimental setups, detailed procedures, and experimental data are included.

Russell, S. S.↗

PillCam(TradeMark), a Noninvasive Endoscopic Device for the Measurement of Gastrointestinal Motility Changes

Introduction: Bioavailability and effectiveness of drugs given by mouth are governed in part by gastrointestinal (GI) motility and function. Microgravity has been shown to decrease GI motility as indicated by a 3 fold increase in gastrointestinal transit time (GITT). The PillCam(TradeMark), an endoscopic camera embedded in a capsule, is a novel noninvasive and unobtrusive device that is used for the diagnosis of GI pathology. The purpose of this study is to evaluate the usefulness of PillCam(TradeMark) as an alternative to the Lactulose Breath Hydrogen Test (LBHT) for estimating GI motility. The sensitivity and applicability of this device for detection and estimation of the effect of promethazine, a deterrent, and caffeine, a prokinetic, on GI motility were also examined. Method: In this semi-randomized cross-over design study, six male and six female subjects were administered the following 4 treatments: PillCam(TradeMark) alone, PillCam(TradeMark)+Lactulose (10g), PillCam(TradeMark)+caffeine (200mg), and PillCam(TradeMark)+Promethazine (50mg). Results: GITT ranged between 1:24 and 7:52 hr:min. Lactulose did not alter GITT. A significant increase in GITT was noticed after administration of PMZ when compared to values from PillCam(TradeMark) treatment alone or PillCam(TradeMark)+Lactulose treatment. No difference in GITT after caffeine treatment was noticed. While there were no gender related differences in GITT after administration of PillCam(TradeMark) or with lactulose, a significant difference (p<.05) between genders was observed after promethazine administration with mean GITT higher in males (5:50 hr:min) than females (4:15 hr:min). Conclusion: The PillCam(TradeMark) capsule is applicable for the determination of GITT using time stamped GI images. It can be successfully used for the assessment of drug induced changes in GI motility and therefore, may be applicable for microgravity and analog environment studies on GI motility and function.

Vaksman, Zahman↗

Stereo Imaging Miniature Endoscope

Stereo imaging requires two different perspectives of the same object and, traditionally, a pair of side-by-side cameras would be used but are not feasible for something as tiny as a less than 4-mm-diameter endoscope that could be used for minimally invasive surgeries or geoexploration through tiny fissures or bores. The proposed solution here is to employ a single lens, and a pair of conjugated, multiple-bandpass filters (CMBFs) to separate stereo images. When a CMBF is placed in front of each of the stereo channels, only one wavelength of the visible spectrum that falls within the passbands of the CMBF is transmitted through at a time when illuminated. Because the passbands are conjugated, only one of the two channels will see a particular wavelength. These time-multiplexed images are then mixed and reconstructed to display as stereo images. The basic principle of stereo imaging involves an object that is illuminated at specific wavelengths, and a range of illumination wavelengths is time multiplexed. The light reflected from the object selectively passes through one of the two CMBFs integrated with two pupils separated by a baseline distance, and is focused onto the imaging plane through an objective lens. The passband range of CMBFs and the illumination wavelengths are synchronized such that each of the CMBFs allows transmission of only the alternate illumination wavelength bands. And the transmission bandwidths of CMBFs are complementary to each other, so that when one transmits, the other one blocks. This can be clearly understood if the wavelength bands are divided broadly into red, green, and blue, then the illumination wavelengths contain two bands in red (R1, R2), two bands in green (G1, G2), and two bands in blue (B1, B2). Therefore, when the objective is illuminated by R1, the reflected light enters through only the left-CMBF as the R1 band corresponds to the transmission window of the left CMBF at the left pupil. This is blocked by the right CMBF. The transmitted band is focused on the focal plane array (FPA).

Bae, Youngsam↗

Endoscope and System and Method of Operation Thereof

An endoscope including a rigid section having opposed first and second ends and an opening situated between the first and second ends, the rigid section defining a longitudinal axis; a handle portion coupled to a first end of the rigid section and having first and second scissor-type handles suitable for grasping by a user; and a base part situated at the second end of the rigid section and coupled to the first handle of the scissor-type handles such that displacement of the first handle causes a rotation of the base part.

Manohara, Harish M.↗

3D Endoscope to Boost Safety, Cut Cost of Surgery

Researchers at the Jet Propulsion Laboratory worked with the brain surgeon who directs the Skull Base Institute in Los Angeles to create the first endoscope fit for brain surgery and capable of producing 3D video images. It is also the first to be able to steer its lens back and forth. These improvements to visibility are expected to improve safety, speeding patient recovery and reducing medical costs.

Source record↗

Endoscope and System and Method of Operation Thereof

An endoscope including a rigid section having opposed first and second ends and an opening situated between the first and second ends, the rigid section defining a longitudinal axis; a handle portion coupled to a first end of the rigid section and having first and second scissor-type handles suitable for grasping by a user; and a base part situated at the second end of the rigid section and coupled to the first handle of the scissor-type handles such that displacement of the first handle causes a rotation of the base part.

Manohara, Harish M.↗

Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters

A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.

Shahinian, Hrayr Karnig↗