Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration framework that is clinically valuable and requires no specialized equipment.

60 APPLIED LIFE SCIENCES↗

Automatic detection of small bowel tumors in wireless capsule endoscopy images using ensemble learning

Purpose Wireless Capsule Endoscopy (WCE) is a minimally invasive diagnosis tool for lesion detection in the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the significant amount of acquired data leads to difficulties in the diagnosis by the physicians; which can be eased with computer assistance. This paper addresses a method for the automatic detection of tumors in WCE by using a two‐step based procedure: region of interest selection and classification. Methods The first step aims to separate abnormal from normal tissue by using automatic segmentation based on a Gaussian Mixture Model (GMM). A modified version of the Anderson method for convergence acceleration of the expectation–maximization (EM) algorithm is proposed. The proposed features for both segmentation and classification are based on the CIELab color space, as a way of bypassing lightness variations, where the L component is discarded. Tissue variability among subjects, light inhomogeneities and even intensity differences among different devices can be overcome by using simultaneously features from both regions. In the second step, an ensemble system with partition of the training data with a new training scheme is proposed. At this stage, the gating network is trained after the experts have been trained decoupling the joint maximization of both modules. The partition module is also used at the test step, leading the incoming data to the most likely expert allowing incremental adaptation by preserving data diversity. Results This algorithm outperforms others based on texture features selected from Wavelets and Curvelets transforms, classified by a regular support vector machine (SVM) in more than 5%. Conclusions This work shows that simpler features can outperform more elaborate ones if appropriately designed. In the current case, luminance was discarded to cope with saturated tissue, facilitating the color perception. Ensemble systems remain an open research field. In the current case, changes in both topology and training strategy have led to significant performance improvements. A system with this level of performance can be used in current clinical practice.

Vieira, Pedro M.↗

Clinical Outcome of the Visible Coil During Endoscopy After Transcatheter Arterial Embolization for Gastrointestinal Bleeding

Purpose: This study was designed to evaluate the clinical outcome of the visible coil during endoscopy after transcatheter arterial embolization (TAE) for gastrointestinal bleeding. Methods: We retrospectively reviewed the medical records of 1415 patients who underwent TAE for gastrointestinal bleeding between 2001 and 2017. Among these 1415 patients, 70 underwent TAE using coils and consecutive follow-up endoscopy. Finally, 11 patients with an extravascular coil seen on follow-up endoscopic examination were included in this study. We evaluated the underlying cause of the gastrointestinal bleeding, the technical and clinical success rates, the type of extravascular coil after TAE, and the clinical outcomes of the extravascular coil seen on follow-up endoscopic examination. Results: Of the 11 patients, the most common underlying cause of gastrointestinal bleeding was a duodenal ulcer (n = 7). On angiography, the bleeding artery was most commonly found in the gastroduodenal artery (n = 6). The technical success and clinical success rates of TAE were 100% and 90.9%, respectively. The type of extravascular coil found on endoscopic examination was classified by submucosal migration (n = 6) and protrusion (n = 5). On second-look endoscopic evaluation, 10 of 11 (90.9%) patients showed healing ulceration. On the final-look endoscopic evaluation, healing ulceration without further bleeding was seen in one (9.1%) patient and scar formation was seen in ten (90.9%) patients. Conclusions: Extravascular coil after TAE for gastrointestinal bleeding is rare, and the most common underlying cause is duodenal ulcer bleeding. The extravascular coils eventually show a healing process with adequate treatment of underlying bowel pathologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-80: Beta-Minus Emitting Radiotracers Improves Molecular Endoscopy

Purpose: Molecular Endoscopy using Cerenkov Luminescence can be used to monitor the distribution of many clinically-available PET and SPECT probes for endoscopic applications. A main limitation of Cerenkov is its limited sensitivity to small concentrations of radiotracer when using light guides s. Herein we demonstrate that the use of a high energy beta emitting radioisotope, exemplified here with 90Y provides superior sensitivity to 18F because of its higher light output and its lack of corresponding gamma emission. Methods: A series of phantom experiments were performed to compare the sensitivity and noise of the CLE system for imaging 90Y and 18F. Three vials of known concentrations of 90Y (0.008 μCi, 0.08 μCi, 1 μCi) were placed in centrifuge tubes and isolated from each other. One vial of 18F (100 μCi) was placed in the imaging chamber and imaged over the course of decay (19 hours, 43 minutes, or ∼10 half-lives). Image time-points were formed from 5-minute integrations. Results: Using an SNR of 10 to define the noise-floor, the 90Y minimum detectable activity was 0.056 μCi. To the contrast, the minimum detectable activity for 18F was 11.63 μCi. These data demonstrate a 207-fold improvement in SNR of 90Y compared to 18F, when controlled for activity. Conclusion: This study demonstrated that a pure β- radionuclide such as 90Y be used is superior to 18F for Cerenkov Endoscopy. Further study is needed to demonstrate its utility in preclinical studies, endoscopic applications, intraoperative, and radiotherapy applications.

07 ISOTOPE AND RADIATION SOURCES↗

Cerenkov luminescence endoscopy: Improved molecular sensitivity with β - -emitting radiotracers

Cerenkov luminescence endoscopy (CLE) is an optical technique that captures the Cerenkov photons emitted from highly energetic moving charged particles (β + or β $-$ ) and can be used to monitor the distribution of many clinically available radioactive probes. A main limitation of CLE is its limited sensitivity to small concentrations of radiotracer, especially when used with a light guide. We investigated the improvement in the sensitivity of CLE brought about by using a β $-$ radiotracer that improved Cerenkov signal due to both higher β-particle energy and lower γ noise in the imaging optics because of the lack of positron annihilation. Here, the signal-to-noise ratio (SNR) of 90 Y was compared with that of 18 F in both phantoms and small-animal tumor models. Sensitivity and noise characteristics were demonstrated using vials of activity both at the surface and beneath 1 cm of tissue. Rodent U87MG glioma xenograft models were imaged with radiotracers bound to arginine-glycine-aspartate (RGD) peptides to determine the SNR. As a result, γ noise from 18 F was demonstrated by both an observed blurring across the field of view and a more pronounced fall-off with distance. A decreased γ background and increased energy of the β particles resulted in a 207-fold improvement in the sensitivity of 90 Y compared with 18 F in phantoms. 90 Y-bound RGD peptide produced a higher tumor-to-background SNR than 18 F in a mouse model. In conclusion, the use of 90 Y for Cerenkov endoscopic imaging enabled superior results compared with an 18 F radiotracer.

60 APPLIED LIFE SCIENCES↗

Project Report: Reducing Color Rivalry in Imagery for Conjugated Multiple Bandpass Filter Based Stereo Endoscopy

A pair of conjugated multiple bandpass filters (CMBF) can be used to create spatially separated pupils in a traditional lens and imaging sensor system allowing for the passive capture of stereo video. This method is especially useful for surgical endoscopy where smaller cameras are needed to provide ample room for manipulating tools while also granting improved visualizations of scene depth. The significant issue in this process is that, due to the complimentary nature of the filters, the colors seen through each filter do not match each other, and also differ from colors as seen under a white illumination source. A color correction model was implemented that included optimized filter selection, such that the degree of necessary post-processing correction was minimized, and a chromatic adaptation transformation that attempted to fix the imaged colors tristimulus indices based on the principle of color constancy. Due to fabrication constraints, only dual bandpass filters were feasible. The theoretical average color error after correction between these filters was still above the fusion limit meaning that rivalry conditions are possible during viewing. This error can be minimized further by designing the filters for a subset of colors corresponding to specific working environments.

conjugated multiple bandpass filters (CMBF)↗

Improving superficial target delineation in radiation therapy with endoscopic tracking and registration

Purpose: Target delineation within volumetric imaging is a critical step in the planning process of intensity modulated radiation therapy. In endoluminal cancers, endoscopy often reveals superficial areas of visible disease beyond what is seen on volumetric imaging. Quantitatively relating these findings to the volumetric imaging is prone to human error during the recall and contouring of the target. We have developed a method to improve target delineation in the radiation therapy planning process by quantitatively registering endoscopic findings contours traced on endoscopic images to volumetric imaging. Methods: Using electromagnetic sensors embedded in an endoscope, 2D endoscopic images were registered to computed tomography (CT) volumetric images by tracking the position and orientation of the endoscope relative to a CT image set. Regions-of-interest (ROI) in the 2D endoscopic view were delineated. A mesh created within the boundary of the ROI was projected onto the 3D image data, registering the ROI with the volumetric image. This 3D ROI was exported to clinical radiation treatment planning software. The precision and accuracy of the procedure was tested on two solid phantoms with superficial markings visible on both endoscopy and CT images. The first phantom was T-shaped tube with X-marks etched on the interior. The second phantom was an anatomically correct skull phantom with a phantom superficial lesion placed on the pharyngeal surface. Markings were contoured on the endoscope images and compared with contours delineated in the treatment planning system based on the CT images. Clinical feasibility was tested on three patients with early stage glottic cancer. Image-based rendering using manually identified landmarks was used to improve the registration. Results: Using the T-shaped phantom with X-markings, the 2D to 3D registration accuracy was 1.5-3.5 mm, depending on the endoscope position relative to the markings. Intraobserver standard variation was 0.5 mm. Rotational accuracy was within 2 deg. Using the skull phantom, registration accuracy was assessed by calculating the average surface minimum distance between the endoscopy and treatment planning contours. The average surface distance was 0.92 mm with 93% of all points in the 2D-endoscopy ROI within 1.5 mm of any point within the ROI contoured in the treatment planning software. This accuracy is limited by the CT imaging resolution and the electromagnetic (EM) sensor accuracy. The clinical testing demonstrated that endoscopic contouring is feasible. With registration based on em tracking only, accuracy was 5.6-8.4 mm. Image-based registration reduced this error to less than 3.5 mm and enabled endoscopic contouring in all cases. Conclusions: Registration of contours generated on 2D endoscopic images to 3D planning space is feasible, with accuracy smaller than typical set-up margins. Used in addition to standard 3D contouring methods in radiation planning, the technology may improve gross tumour volume (GTV) delineation for superficial tumors in luminal sites that are only visible in endoscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Severe Gastrointestinal Haemorrhage: Summary of a National Quality of Care Study with Focus on Radiological Services

Purpose of StudyTo identify the remediable factors in the quality of care provided to patients with severe gastrointestinal (GI) bleeding.MethodAll hospital admissions in the first four months of 2013 with ICD10 coding for GI bleeding who received a transfusion of 4 units or more of blood. Up to five cases/hospital randomly selected for structured case note peer review. National availability of GI bleeding services data derived from organisational questionnaire completed by all hospitals.Results4563/29,796 (15.3%) of GI bleeds received 4 or more units of blood with a mortality rate of 20.2% compared to 7.3% without blood transfusion. 30.8% of GI bleeds received a blood transfusion. 32% (60/185) of hospitals admitting acute GI bleeds lacked 24/7 endoscopy. 26% (48/185) had on-site embolisation 24/7 with a further 34% (64/185) accessing embolisation by transfer within a validated formal network. Blood product use was inappropriate in 20% (84/426). Improved management, principally earlier senior gastroenterologist review and/or endoscopy, would have reduced blood product use in 25% (113/457). 14.5% (90/618) had a CT scan which identified the site of bleeding in 32% (29/90). 7.8% (36/459) underwent an Interventional Radiology (IR) procedure but a further 6.3% (21/33) should have had IR. 6% (36/586) underwent surgery with 21/36 for uncontrolled bleeding. In 20/35 IR was not considered despite the majority being suitable for IR. Overall 44% (210/476) received an acceptable standard of care according to peer review.Conclusions26 recommendations were made to improve the quality of care in GI bleeding, with six principle recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastric Embolization as Treatment for Overweight Patients; Efficacy and Safety

Objectives: The aim of this study was to evaluate the efficacy and safety of left gastric artery (LGA) embolization for the treatment of overweight patients who weren’t candidates for bariatric surgery. Materials and Methods: We retrospectively collected data of 16 patients who underwent a selective embolization of the LGA. The mean body mass index (BMI) before intervention was 28.9 kg/m{sup 2} ± 2.5, and therefore, patients were not candidates for bariatric surgery in Belgium. The embolization was realized with 500–700 µm particles via the right common femoral artery approach. Before and following the intervention, an upper endoscopy was performed. Patient demographics, weight loss, hunger sensation and a satisfactory scale were reviewed. Results: Between February 2015 and May 2017, 16 overweight patients were treated, one embolization was unsuccessful. Four (25%) patients were lost in follow-up. Nine (56%) patients showed early weight loss, one (6%) maintained his bodyweight and one (6%) patient underwent bariatric surgery 2 years after consultation. Only one (6%) patient had a gastric ulceration on control endoscopy. One (6%) patient ended in the intensive care unit for pancreatitis and gastric perforation. The mean weight loss was 8 kg ± 5.12, reducing their mean BMI to 25.5 ± 3.5. The hunger sensation was decreased, and patients were satisfied. Conclusion: This is a preliminary study in an overweight population that appears to induce weight loss and appetite suppression. Larger studies are needed to confirm these preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of Conformal Radiotherapy for Progressive Airway Amyloidosis

Purpose: To evaluate the efficacy of conformal external beam radiotherapy (RT) for local control of progressive airway amyloidosis. Methods and Materials: We conducted a retrospective review of patients with biopsy-proven progressive airway amyloidosis treated with conformal RT between 2000 and 2006 at Boston Medical Center. The patients were evaluated for performance status and pulmonary function, with computed tomography and endoscopy after RT compared with the pretreatment studies. Local control was defined as the lack of progression of airway wall thickening on computed tomography imaging and stable endobronchial deposits by endoscopy. Results: A total of 10 symptomatic airway amyloidosis patients (3 laryngeal and 7 tracheobronchial) received RT to a median total dose of 20 Gy in 10 fractions within 2 weeks. At a median follow-up of 6.7 years (range, 1.5-10.3), 8 of the 10 patients had local control. The remaining 2 patients underwent repeat RT 6 and 8.4 months after initial RT, 1 for persistent bronchial obstruction and 1 for progression of subglottic amyloid disease with subsequent disease control. The Eastern Cooperative Oncology Group performance status improved at a median of 18 months after RT compared with the baseline values, from a median score of 2 to a median of 1 (p = .035). Airflow (forced expiratory volume in 1 second) measurements increased compared with the baseline values at each follow-up evaluation, reaching a 10.7% increase (p = .087) at the last testing (median duration, 64.8 months). Acute toxicity was limited to Grade 1-2 esophagitis, occurring in 40% of patients. No late toxicity was observed. Conclusions: RT prevented progressive amyloid deposition in 8 of 10 patients, resulting in a marginally increased forced expiratory volume in 1 second, and improved functional capacity, without late morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Sodium Butyrate Enema for the Prevention of Radiation Proctitis in Prostate Cancer Patients Undergoing Radical Radiation Therapy: Results of a Multicenter Randomized Placebo-Controlled Dose-Finding Phase 2 Study

Purpose: To evaluate the efficacy of sodium butyrate enemas (NABUREN) in prostate cancer radiation therapy (RT) in reducing the incidence, severity, and duration of acute RT-induced proctitis. Methods and Materials: 166 patients, randomly allocated to 1 of 4 groups (rectal sodium butyrate 1 g, 2 g, or 4 g daily or placebo), were treated with NABUREN during and 2 weeks after RT. The grade of proctitis was registered in a daily diary. The correlation between NABUREN and proctitis was investigated through χ{sup 2} statistics. The toxicity endpoints considered were as follows: total number of days with grade ≥1 proctitis (≥G1); total number of days with grade ≥2 proctitis (≥G2); ≥G1 and ≥G2 proctitis lasting at least 3 and 5 consecutive days starting from week 4 (≥G1+3d, ≥G2+3d); damaging effects of RT on rectal mucosa as measured by endoscopy. The relationship between endpoints and pretreatment morbidities, hormonal therapy, presence of diabetes or hypertension, abdominal surgery, or hemorrhoids was investigated by univariate analysis. Results: The patients were randomly allocated to the 4 arms. No difference in the distribution of comorbidities among the arms was observed (P>.09). The mean ≥G1 and ≥G2 proctitis were 7.8 and 4.9 for placebo and 8.9 and 4.7 for the NABUREN group, respectively. No favorable trend in reduction of incidence, severity, and duration of ≥G1 and ≥G2 proctitis was observed with NABUREN use. In univariate analysis, ≥G1+3d toxicity was found to be related to hemorrhoids (P=.008), and a slight correlation was found between ≥G2 proctitis and hormonal therapy (P=.06). The RT effects on rectal mucosa as based on endoscopic assessment were mainly related to diabetes (P<.01). Endoscopy data at 6 week showed no significant difference between the placebo and butyrate arms. The other investigated endpoints were not correlated with any of the clinical risk factors analyzed. Conclusion: There was no evidence of efficacy of NABUREN in reducing the incidence, severity, and duration of acute radiation proctitis. There was a correlation between some endpoints and clinical risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).

Jackson, Deborah↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

Jackson, Deborah↗