At least 19 records

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Advanced District Energy Controls for Improved Efficiency and Resilience

District energy (DE) systems have efficiently provided heat and cooling to buildings in the US for over a century by leveraging economies of scale through shared generation assets. However, optimizing DE boiler and chiller plants is complex due to the intricate mix of equipment and multiple operating flows. Sophisticated controls are necessary to achieve highest efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Who Controls Energy in the Smart Home? A Multidisciplinary Taxonomy

Advances in technology have begun to open new opportunities for behavior-based and technical approaches to managing residential energy use and meet sustainability-related objectives. Visions of the future predict homes with smart technologies delivering enhanced comfort and cost savings to residents; utility-partners who can remotely optimize energy resources to meet grid needs; and occupants who play more active roles in the energy system supported by advanced information communication technologies. Each of these scenarios implies augmented control over home energy use, yet uncertainties remain regarding which ones will deliver the greatest grid benefits and services to customers in a given situation. These scenarios also raise broader questions regarding customer agency and the relationship between customers and third parties moving forward. While both the provision of information to spur behavior change and automated technologies theoretically enhance control over energy use in the built environment, these strategies are not often studied from an integrated perspective. Seeking to address this gap and develop a deeper understanding of the evolving paradigm of control over home energy use, this paper presents a taxonomy to evaluate perspectives from public policy (ex. demand-side management), technological innovation (automated controls), and user-agency (ex. the role of behavior change) on approaches to managing home energy use. We draw on theoretical and empirical evidence from across disciplines to detail the dimensions and implications of deploying programs that incorporate various levels of control and anticipate such a taxonomy will help holistically map out and evaluate tradeoffs between different approaches to demand-side management moving forward.

McIlvennie, Claire↗

The wave energy converter control competition (WECCCOMP): Wave energy control algorithms compared in both simulation and tank testing

The wave energy control competition established a benchmark problem which was offered as an open challenge to the wave energy system control community. The competition had two stages: In the first stage, competitors used a standard wave energy simulation platform (WEC-Sim) to evaluate their controllers while, in the second stage, competitors were invited to test their controllers in a real-time implementation on a prototype system in a wave tank. The performance function used was based on converted energy across a range of standard sea states, but also included aspects related to economic performance, such as peak/average power, peak force, etc. This paper compares simulated and experimental results and, in particular, examines if the results obtained in a linear system simulation are borne out in reality. Overall, within the scope of the device tested, the range of sea states employed, and the performance metric used, the conclusion is that high-performance WEC controllers work well in practice, with good carry-over from simulation to experimentation. However, the availability of a good WEC mathematical model is deemed to be crucial.

16 TIDAL AND WAVE POWER↗

Western States Building Energy & Controls Apprenticeship (BECA) Program

How does this project help to understand the challenges of workforce development in the commercial building energy management industry? The purpose of this project was to create a replicable, scalable, and portable apprenticeship program for building energy management and controls. This paper will demonstrate how local processes can be more adaptable and inclusive than federal processes in achieving workforce development goals. Our work provides insights into the technical effectiveness of the program, enabling others to achieve greater success in their workforce development initiatives. The project required more time and financial resources than initially anticipated and spent a year in a no-cost extension working to accomplish the Statement of Project Objectives. The original goal was to create an Industry Related Apprenticeship Program (IRAP). The development of this apprenticeship presented challenges due to the lack of existing programs for reference and the absence of relevant industry classification codes by the Department of Labor (DOL). Notably, the role of a commercial building energy analyst is not recognized by the DOL. The SIC (industry codes) do not have a good description of this job. There are many that may fall into related categories, but none are the actual duties of an energy analyst. Discussions with the DOL indicated that substantial groundwork was necessary before a national apprenticeship program could be implemented, causing delays in the program’s commencement. As a result, students experienced longer wait times before starting their apprenticeship component. The apprenticeship program officially launched on September 14, 2021. The success of the State of Oregon’s apprenticeship program, the first of its kind in the state, underscored the flexibility and effectiveness of local initiatives compared to federal efforts. The COVID-19 pandemic also significantly impacted the project’s success. Beginning in March 2020, the pandemic led to widespread closures of schools and colleges by fall 2020. By September 2021, when the apprenticeship option became available, enrollment in colleges and universities nationwide had decreased, affecting student participation in the program. Moreover, as employers transitioned their employees to remote work, there was limited interaction with external personnel, influencing the willingness of training agents (employers) to integrate additional workers into their teams. This paper addresses several challenges encountered during the project, with the hope that future workforce development efforts will benefit from these experiences. We Final Technical Report 4 | Page encourage others to engage with state and federal agencies to enhance and update pathways for workforce development and apprenticeship programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Grain boundary energy control in zinc aluminate nanoceramics

This study investigates the grain boundary energy dependence on segregated dopants in nanocrystalline zinc aluminate ceramics. Atomistic simulations of Σ3 and Σ9 grain boundaries showed that trivalent ions of varying ionic radii [Sc 3+ (74.5 pm), In 3+ (80.0 pm), Y 3+ (90.0 pm), and Nd 3+ (98.3 pm)] have a tendency to segregate to both interfaces, with Y 3+ presenting the highest segregation potentials. The connection between segregation and the reduction of interfacial energies was explored by measuring the grain boundary energy on nanoceramics fabricated via high‐pressure spark plasma sintering (HP‐SPS) using differential scanning calorimetry (DSC). The results revealed that Y 3+ doping at 0.5 mol% reduces the grain boundary energy in zinc aluminate nanoceramics from 1.1–1.3 J/m 2 to 0.6–0.8 J/m 2 ; the range correlates with the observed size dependence of the excess energy, with higher values observed for the smaller grain sizes (∼17 nm). The noted decrease in interfacial energies for doped samples suggests it is indeed possible to alter the stability of zinc aluminate grain boundaries via dopant segregation.

36 MATERIALS SCIENCE↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

Leveraging metal hydrides for strategic thermal energy control

Attributes of Sensible Heat Materials • Typically based on highly abundant and lowcost materials • Store thermal energy based on the heat capacity (or specific heat) of the material • Duration of thermal energy storage depends on how well the system is insulated • Has the lowest thermal energy storage density • Can be pumped as a fluid Attributes of Latent Heat Materials • Also based on highly abundant materials, but typically cost slightly more than sensible heat materials • Store thermal energy based on the heat of the phase change (i.e., heat of fusion) and the specific heat of the material • Duration of thermal energy storage depends on how well the system is insulated • Has a higher thermal energy storage density than sensible heat materials, but cannot be pumped as a fluid

WARD, PATRICK↗

Encapsulation of Monolayer 2D Materials Using Kinetic Energy-Controlled Pulsed Laser Deposition

The integration of monolayer (ML) two-dimensional (2D) materials into next-generation microelectronics, optoelectronics, and sensors is hindered by their sensitivity to environmental exposure. Deposition of additional layers for encapsulation or growth on ML 2D materials by versatile but energetic plasma techniques such as pulsed laser deposition (PLD) has not been considered at the monolayer level because of potential damage caused by hyperthermal species with kinetic energies (KEs) exceeding the threshold displacement energy (TDE) of the ML. Here, we describe a general strategy to understand and mitigate damage during PLD by reducing the incident KE of ablated species below the TDE of the 2D monolayer using background gas collisions. Ion flux diagnostics, combined with in situ Raman spectroscopy of monolayer graphene during PLD of amorphous boron nitride (a-BN) as a dielectric encapsulation layer, show that damage is primarily correlated with fast ions that penetrate the background gas in accordance with Beer’s Law and are often overlooked in ICCD imaging due to the dominance of the bright, delayed plasma luminescence. Significantly, if fast ions are eliminated and a ∼2 nm-thick a-BN layer is “soft landed”, the monolayer graphene is effectively protected from damage by high KE species in the boron nitride plasma plume. Deposited a-BN films display a characteristic dielectric constant of 3.6 at 100 kHz and tunable charge injection properties. Our results enable PLD as a viable option for encapsulation and thin film growth onto ML 2D materials, with implications for both fundamental research and device integration.

2D materials↗

Methodology for interpretable reinforcement learning model for HVAC energy control

Deep reinforcement learning (DRL) approaches have been used in various application areas to improve efficiency, optimization, or automation. However, very little is known about how the DRL algorithms make decisions and what features affect their performance. Using a case study of a DRL based Heating, Ventilation and Air Conditioning (HVAC) optimization methodology, we demonstrate how we can address these challenges by applying interpretability tools and systematically exploring the model inputs for better understanding the DRL behaviour and decision making process. We developed a methodology for interpretable reinforcement learning and evaluated our approach in real-world house located in Knoxville, TN. Our findings explain the reasoning behind DRL-based optimization decisions under different circumstances which has been discussed and confirmed by the experts in the field.

Kotevska, Olivera↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

Hammerstrom, Donald J.↗

Privacy-Preserving Control of Partitioned Energy Resources

Distributed energy resources are an increasingly important part of the electric grid. We examine the problem of partitioning a distributed energy resource among many users while providing privacy to them. In this model, clients can send requests to a server, the server can verify that the requests are valid and aggregate them, but it cannot see the actual values in the requests. Without privacy, each user is forced to reveal their daily schedule or energy use. Energy resources add a novel challenge that prior systems do not address: they require verifying limits on private power (a rate over time) and energy (a sum) values. Furthermore, the cryptographic mechanisms must run on embedded energy control systems. We describe Weft, a novel cryptographic system that verifies both power (rate) and energy (integral) constraints on private client values and aggregates them. The key insight behind the approach is to rely on additively homomorphic secret shares, which allows servers to compute sums from rates. We present 3 cryptographic proof systems with different system trade-off for embedded systems: bit-splitting proofs minimize memory use, sorting proofs minimize computation, and commitment proofs minimize network communication. Using bit-splitting proofs, it takes an IoT client using a CortexM microcontroller 4 minutes of compute time to privately control its share of an energy resource for a day at 20s granularity.

Laufer, Evan↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

Real-Time Sea State Estimation for Wave Energy Converter Control via Machine Learning

Wave energy converters (WECs) harness the untapped power of ocean waves to generate renewable energy, offering a promising solution to sustainable energy. An optimal WEC control strategy is essential to maximize power capture that dynamically adjusts system parameters in response to rapidly changing sea states. This study presents a novel control approach that leverages neural networks to estimate sea states from onboard WEC measurements such as position, velocity, and force. Using a point absorber WEC device as a test platform, our proposed approach estimates sea states in real-time and subsequently adjusts PID controller gains to maximize energy extraction. Simulation results across diverse sea conditions demonstrate that our strategy eliminates the need for external wave monitoring equipment while maintaining power capture efficiency. The results show that our neural network-based control technique can improve power capture by 25.6% while significantly reducing system complexity. This approach offers a practical alternative for WEC deployments where direct wave measurements are either infeasible or cost prohibitive.

PIDcontrol↗