Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Practical On-line Framework for a Modified Energy Detector by Whitening Ambient PMU Data

A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.

Xu, Zikai↗

Power System Event Detection Using the Energy Detector: A Performance Analysis

As the grid becomes smarter, the need to accurately detect, predict, and classify waveform phenomena is growing. When it comes to detecting high-frequency behaviors, i.e. transients, it is especially important to employ an event detection system that is able to accurately uncover these types of disturbances that would otherwise be lost with traditional hardware. In this paper, we first present the energy detector; a waveform event detection system that adaptively monitors a signal's energy and picks out high-frequency events that deviate from the nominal state. Secondly, we evaluate the performance of this detector against waveform data that have been corrupted by sensor irregularities. Using Oak Ridge National Laboratory's sensor testbed, we are able to show the results of the detector's performance against events that have been corrupted by three distinct sensor types, and examine how these results change with multiple trials. The results show excellent performance when detecting the beginning of an anomalous event with an average of less than 1% error.

Ekti, Ali Riza↗

Use of Neutrino Scattering Events with Low Hadronic Recoil to Inform Neutrino Flux and Detector Energy Scale

Charged-current neutrino interactions with low hadronic recoil ("low-nu") have a cross-section that is approximately constant versus neutrino energy. These interactions have been used to measure the shape of neutrino fluxes as a function of neutrino energy at accelerator-based neutrino experiments such as CCFR, NuTeV, MINOS and MINERvA. In this paper, we demonstrate that low-nu events can be used to measure parameters of neutrino flux and detector models and that utilization of event distributions over the upstream detector face can discriminate among parameters that affect the neutrino flux model. From fitting a large sample of low-nu events obtained by exposing MINERvA to the NuMI medium-energy beam, we find that the best-fit flux parameters are within their a priori uncertainties, but the energy scale of muons reconstructed in the MINOS detector is shifted by 3.6% (or 1.8 times the a priori uncertainty on that parameter). These fit results are now used in all MINERvA cross-section measurements, and this technique can be applied by other experiments operating at MINERvA energies, such as DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New directions for surrogate models and differentiable programming for High Energy Physics detector simulation

The computational cost for high energy physics detector simulation in future experimental facilities is going to exceed the current available resources. To overcome this challenge, new ideas on surrogate models using machine learning methods are being explored to replace computationally expensive components. Additionally, differentiable programming has been proposed as a complementary approach, providing controllable and scalable simulation routines. In this document, new and ongoing efforts for surrogate models and differential programming applied to detector simulation are discussed in the context of the 2021 Particle Physics Community Planning Exercise (`Snowmass').

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graph Neural Networks for Particle Reconstruction in High Energy Physics detectors

Pattern recognition problems in high energy physics are notably different from traditional machine learning applications in computer vision. Reconstruction algorithms identify and measure the kinematic properties of particles produced in high energy collisions and recorded with complex detector systems. Two critical applications are the reconstruction of charged particle trajectories in tracking detectors and the reconstruction of particle showers in calorimeters. These two problems have unique challenges and characteristics, but both have high dimensionality, high degree of sparsity, and complex geometric layouts. Graph Neural Networks (GNNs) are a relatively new class of deep learning architectures which can deal with such data effectively, allowing scientists to incorporate domain knowledge in a graph structure and learn powerful representations leveraging that structure to identify patterns of interest. In this work we demonstrate the applicability of GNNs to these two diverse particle reconstruction problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Statistics-Based Threshold for the RMS-Energy Oscillation Detector

System operators and reliability coordinators currently rely on extensive baselining studies to set thresholds for their oscillation detectors. The resulting thresholds are based largely on engineering judgment and may vary significantly between organizations. In this paper, statistical distribution theory is used to derive a detection threshold for the widely deployed root-mean-square (RMS)-energy detector. This expression provides a theoretical basis for the detector's configuration, simplifies the process of selecting the threshold, and enables improved consistency among organizations that need to coordinate during system-wide events. Three methods for calculating the threshold using synchrophasor measurements are also proposed. These methods ensure that the threshold can be calculated reliably for various applications. Tests with simulated and field-measured data demonstrate that the statistics-based threshold provides consistent detection of grid disturbances while maintaining a low probability of false alarm.

Follum, James D.↗

Variational autoencoders for at-source data reduction and anomaly detection in high energy particle detectors

Detectors in next-generation high-energy physics experiments face several daunting requirements, such as high data rates, damaging radiation exposure, and stringent constraints on power, space, and latency. To address these challenges, machine learning in readout electronics can be leveraged for smart detector designs, enabling intelligent inference and data reduction at-source. Variational autoencoders (VAEs) offer a variety of benefits for front-end readout; an on-sensor encoder can perform efficient lossy data compression while simultaneously providing a latent space representation that can be used for anomaly detection. Results are presented from low-latency and resource-efficient VAEs for front-end data processing in a futuristic silicon pixel detector. Encoder-based data compression is found to preserve good performance of off-detector analysis while significantly reducing the off-detector data rate as compared to a similarly sized data filtering approach. Furthermore, the latent space information is found to be a useful discriminator in the context of real-time sensor defect monitoring. Together, these results highlight the multifaceted utility of autoencoder-based front-end readout schemes and motivate their consideration in future detector designs.

47 OTHER INSTRUMENTATION↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Systematic Uncertainties in the NOvA \nu_\mu-Disappearance Analysis

As the NOvA long-baseline neutrino oscillation experiment takes more data, systematic uncertainty begins to more heavily impact the oscillation analyses. The largest effects are calibration on calorimetric energy, detector modeling on muon energy scale, and near-detector pileup on normalization of the far-detector expectation. Cross-section systematics will be discussed in another poster. Detailed studies have justified previous systematics as too conservative and suggested smaller values. Focused study of detector modeling using dE/dx and external measurements constrain the calibration and energy scale uncertainties. A novel technique is used to assess the impact of activity from neutrino activity piling up over signal, where a simulated neutrino is overlaid into both data and simulation. The difference in efficiency of selecting that single neutrino among data and simulated spills then dominates the normalization systematic.

Alion, Tyler [Sussex U.]↗

A Novel Method for Setting Meaningful Thresholds for RMS-Energy Oscillation Detectors

Oscillation detection and mitigation is a crucial aspect of reliable power system operation. Several transmission system operators and reliability coordinators use the RMS-energy method of oscillation detection, but the process of setting thresholds is time and labor intensive. The current industry practice in the United States is to set thresholds based on the RMS-energy's value during ambient conditions, which can often lead to nuisance alarms that require thresholds to be manually retuned. In this paper, we propose a method for setting RMS-energy thresholds that directly accounts for oscillation amplitudes specified by the user. A theoretical analysis of the statistical properties of the RMS-energy incorporates these user-specified amplitudes, resulting in thresholds that reliably detect oscillations of interest while avoiding nuisance alarms. Theoretical results are validated with simulated measurements and the real-world practicality of the method is established with publicly available field-measured data from the Grid Event Signature Library.

Follum, James D.↗

Improving High-Energy Particle Detectors with Machine Learning

Microseconds after the Big Bang, the universe existed in a state called the quark-gluon plasma (QGP). To experimentally study its properties, the QGP is recreated in high-energy nuclear collisions at the LHC, and the particles produced from the QGP are reconstructed from their energy deposition in the ATLAS calorimeter. This requires both classifying the particles and calibrating their deposited energy. The objective of this project is to improve the reconstruction by using machine learning techniques, where the energy depositions of clusters of cells, formed by ATLAS topo-clustering methods, are treated as three-dimensional images when inputted to neural networks. This approach significantly improves the calibration of deposited energies when cross-validating while training, and models trained on idealized data predict the calibrated energies of particles in more complex data sets well. Additionally, implementation of a data generator using uproot allows the program to load input data into memory as needed while training or predicting, significantly reducing the amount of memory used. The data generator also allows for use of multiprocessing to speed up training and evaluating. This work illustrates that using machine learning methods for both classification and calibration has the potential to significantly improve particle reconstruction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Valence-to-core X-ray emission spectroscopy of titanium compounds using energy dispersive detectors

X-ray emission spectroscopy (XES) of transition metal compounds is a powerful tool for investigating the spin and oxidation state of the metal centers. Valence-to-core (vtc) XES is of special interest, as it contains information on the ligand nature, hybridization, and protonation. To date, most vtc-XES studies have been performed with high-brightness sources, such as synchrotrons, due to the weak fluorescence lines from vtc transitions. Here, we present a systematic study of the vtc-XES for different titanium compounds in a laboratory setting using an X-ray tube source and energy dispersive microcalorimeter sensors. With a full-width at half-maximum energy resolution of approximately 4 eV at the Ti Kβ lines, we measure the XES features of different titanium compounds and compare our results for the vtc line shapes and energies to previously published and newly acquired synchrotron data as well as to new theoretical calculations. Finally, we report simulations of the feasibility of performing time-resolved vtc-XES studies with a laser-based plasma source in a laboratory setting. Our results show that microcalorimeter sensors can already perform high-quality measurements of vtc-XES features in a laboratory setting under static conditions and that dynamic measurements will be possible in the future after reasonable technological developments.

36 MATERIALS SCIENCE↗

Detector Instrumentation, Energy Reconstruction and Data Analysis in the DUNE and NOvA Neutrino Experiments

Neutrino oscillations are so far the only experimental observation beyond the standard model since its development four decades ago. The remaining fundamental questions that can be answered by long-baseline neutrino oscillations are (1) the CP violation (whether neutrinos and antineutrinos behave the same way in oscillation), and (2) the mass hierarchy ($m_3>m_{1,2}$ or $m_{1,2}>m_3$), and (3) the octant of $\theta_{23}$ ($\theta_{23}>45^\circ, =45^\circ$ or $<45^\circ$). The PI's group at UCI focuses on long-baseline neutrino experiments DUNE and NOvA, key components of DOE's Intensity Frontier program. NOvA is the current major U.S.-based long-baseline neutrino experiment aiming to solve the mass hierarchy and $\theta_{23}$ octant. It is taking $\nu$ and $\bar{\nu}$ data from the NuMI beam at Fermilab. DUNE is the next-generation flagship neutrino experiment in the U.S. which is designed to decisively determine neutrino CP violation, mass hierarchy and $\theta_{23}$ octant. DUNE is Fermilab's first priority, and has been established as an international collaboration. During the period covered by the report, the PI's group has been exceptionally productive, with leading contributions to DUNE argon-purity monitoring detectors, NOvA/DUNE deep-learning reconstruction, and NOvA oscillation and near detector (ND) analyses. The group also is actively involved in DUNE/NOvA detector operation, data production, calibration, software upgrade and maintenance, and ProtoDUNE cold electronic QA/QC. Specifically, we have made accomplishments in the following four research projects: 1) Purity monitor R\&D and data analysis for DUNE, 2) Deep-learning-based energy reconstruction at NOvA and DUNE, 3) Oscillation analysis at NOvA, and 4) $\nu$-e elastic scattering analysis at NOvA.

47 OTHER INSTRUMENTATION↗

Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]

The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗