Search NASA⌕ Search

SEARCH · Search NASA

Results for “enterprise information architecture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Future Electric Power Industry and Grids—Now What Again is Our Destination?

Having a vision that others agree to support and work toward is highly desirable but hard to achieve. We seem to lack a common and shared understanding of the vision—or worse, multiple visions (vivid mental images or documented statements) with varying areas of focus and details: • some appear to be similar but have differing underlying goals and characteristics, or • some reflect differing viewpoints as to effects on various stakeholders. These desirable and undesirable situations apply to realizing visions for enterprise and industry, including the electricity sector. Multiple industry stakeholder groups have developed goals, industry vision statements, and characterizations of the future. The viewpoints are promoted, discussed, refined by their stakeholder group, and often published to promote broad understanding and to inform or influence others. The GridWise Architecture Council asked itself how well-aligned these characterizations of the future are. If these publications collectively set the overall direction for the industry, it is useful to identify their answers to questions such as, where is the electric industry headed, guided by what objectives, and with what role(s) for the customers, electric utilities, and other stakeholders? Are these goals, visions, and future states moving toward a common vision, do they provide value for the stakeholders, and are they likely to meet the objective stated? This paper addresses these questions via an assessment and characterization of a sampling of stakeholder groups’ publicly available vision and future state reports for the electricity industry. Identified electric power grid architectural topic areas needing further work are described, along with GridWise Architecture Council analysis and observation, potential collaborative work efforts, and suggested next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: Doppelpaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019

The DoppelPaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019 Precursor Analysis Report leverages publicly available information about the PEMEX cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The 2019 DoppelPaymer ransomware attack on PEMEX, Mexico’s nationalized petroleum corporation, highlights a unique threat that ransomware and cybercriminal extortion poses to Operational Technology (OT) environments in critical infrastructure. The incident began with an employee downloading commodity malware that allowed adversaries to gain initial access to PEMEX’s enterprise environment. After conducting privilege escalation, tool ingress, and data exfiltration, the adversaries deployed DoppelPaymer ransomware throughout the PEMEX enterprise environment, resulting in the company having to take dozens of systems offline for at least several days. Although PEMEX stated that their operations were not affected, the data exfiltrated from PEMEX was made available for download on DoppelPaymer’s leak site, as well as on other illicit criminal forums. This stolen data included not only company information, but also sensitive OT-specific configuration data. This incident showcases how cybercriminal exfiltration and posting of sensitive OT architecture documentation can pose security concerns for the targeted organization for years due to the long lifespan of OT assets and architectures. Researchers and analysts identified 18 unique techniques utilized during the attack with a total of 190 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the DoppelPaymer ransomware attack were precursors to the triggering event. Analysis identified 163 observables associated with these precursor techniques, 34 of which were assessed to have an increased likelihood of being perceived in the 60 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Using Splunk® Enterprise Search Commands for Advanced Analysis of Ivanti Connect Secure© Logs

Analyzing the logs of even the smallest Information Technology (IT) system can be a challenge considering they can generate millions of lines of log data in a very short time. Splunk® Enterprise is an industry leading tool that allows analysis of log data, which can enhance troubleshooting capabilities, improve system performance, and improve the security posture of an IT system. Ivanti Connect Secure© (ICS) is a market-leading platform powered by the Ivanti Secure Socket Layer Virtual Private Network (SSL VPN) appliance, providing an architecture for secure access to and protection of network resources. This paper describes an approach for using Splunk Enterprise search capabilities to perform advanced data analysis of ICS logs.

97 MATHEMATICS AND COMPUTING↗

System-Level Integration of Modular Language Models for Real-Time Risk Assessment in Third-Party Risk Management Systems

Large enterprises typically rely on dedicated teams to govern and implement security measures throughout their supply chains, ensuring compliance with enterprise security procedures. There is a significant reliance on Third-Party Risk Management (TPRM) platforms, which often require complete, highly structured information from potential vendors. The review and compliance assurance processes are time- and labor intensive, often requiring several rounds of review between the supply chain security risk management teams, business users, and potential vendors, leading to delays in the supply chain processing and consumer experience. Significant challenges in the risk management paradigm include handling unstructured data in various formats and providing real-time feedback to users to reduce the required review time. This paper presents a novel solution to these challenges. A modular multi-step system architecture is proposed using advances in language processing, specifically for unstructured responses and provides real-time feedback (i.e., 3 seconds) so that users can improve their responses before the TPSRM team review. This novel system architecture will increase information accuracy and significantly reduce time and labor during the review process.

99 - GENERAL AND MISCELLANEOUS↗

SD-WAN Evaluation Criteria for a Defense Information Systems Network Expeditionary Customer Edge

The Defense Information Systems Agency (DISA) has identified a service provision gap midway between the capacity and capability of a Defense Information Systems Network (DISN) transport Edge Points of Presence (POP) and U.S. Department of Defense (DoD) Enterprise Classified Travel Kit (DECTK). Some deployed force 100-user Tactical Operations Centers are in field locations far removed from the DISN transport core, in challenging environmental conditions with limitations on space, weight, power, and cooling for network equipment. As part of a multi-phase project, Pacific Northwest National Laboratory (PNNL) will gather and analyze requirements, design, develop, prototype, and test a miniaturized and ruggedized DISN Customer Edge POP scaled to support approximately 100 users in a field Tactical Operations Center. An Expeditionary Customer Edge (ECE) will be more suitable for field deployment than a DISN transport Edge POP, using ruggedized hardware and network function virtualization (NFV) to operate in challenging field environmental conditions, plus reduce weight, power, and cooling requirements. A key enabling technology for ECE is Software Defined Wide Area Networking (SD-WAN). This document provides: • A brief overview of SD-WAN use cases and how they apply to ECE • How SD-WAN technology compares to existing networks like DISN that use Optical Transport Networking (OTN) and Multiprotocol Label Switching (MPLS) • SD-WAN functional requirements relevant to ECE • A description of an ECE Virtual Prototype, including simulated wide area network paths and a DISN-representative implementation of MPLS, in Cisco Modeling Labs • Detailed network flow walkthroughs • Evaluation criteria based on ECE-relevant SD-WAN functional requirements Finally, an appendix provides an informal evaluation of Speedify—a commercial retail Virtual Private Network service—against the ECE SD-WAN evaluation criteria.

42 ENGINEERING↗