At least 19 records

Adaptive Envelope Detector-Based Phase Fault Detection Method for Power System Grid Distortions

In this study, a phase fault detection algorithm is developed by employing the envelope detector method. The proposed method diagnoses faults among phases and defines fault areas in the incoming signal. The designed algorithm consists of three steps: analytical signal conversion, complex magnitude, and fault detection. Initially, an analytical signal is obtained from the incoming power signal to determine the instantaneous amplitude and phase of the signal. A complex magnitude operation is applied to analytical signals to display changes in amplitude. On the basis of the threshold values specified by the user, the last step identifies the distortion signal in terms of the type of error and size. The proposed method is tested with realistically simulated substation power signal data and real power system data from the Grid Event Signature Library. The obtained results revealed that the proposed method detects distortions accurately.

Alaca, Ozgur↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-91: Correction Method to Determine Surface Dose for OSL Detectors

Purpose: OSL detectors are commonly used in clinic due to their numerous advantages, such as linear response, negligible energy, angle and temperature dependence in clinical range, for verification of the doses beyond the dmax. Although, due to the bulky shielding envelope, this type of detectors fails to measure skin dose, which is an important assessment of patient ability to finish the treatment on time and possibility of acute side effects. This study aims to optimize the methodology of determination of skin dose for conventional accelerators and a flattening filter free Tomotherapy. Methods: Measurements were done for x-ray beams: 6 MV (Varian Clinac 2300, 10×10 cm{sup 2} open field, SSD = 100 cm) and for 5.5 MV (Tomotherapy, 15×40 cm{sup 2} field, SAD = 85 cm). The detectors were placed at the surface of the solid water phantom and at the reference depth (dref=1.7cm (Varian 2300), dref =1.0 cm (Tomotherapy)). The measurements for OSLs were related to the externally exposed OSLs measurements, and further were corrected to surface dose using an extrapolation method indexed to the baseline Attix ion chamber measurements. A consistent use of the extrapolation method involved: 1) irradiation of three OSLs stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. Results: OSL measurements showed an overestimation of surface doses by the factor 2.31 for Varian 2300 and 2.65 for Tomotherapy. The relationships: SD{sup 2300} = 0.68 × M{sup 2300}-12.7 and SDτoμo = 0.73 × Mτoμo-13.1 were found to correct the single OSL measurements to surface doses in agreement with Attix measurements to within 0.1% for both machines. Conclusion: This work provides simple empirical relationships for surface dose measurements using single OSL detectors.

60 APPLIED LIFE SCIENCES↗

High energy neutrinos from choked GRBs and their flavor ratio measurement by the IceCube

The high energy neutrinos produced in a choked gamma-ray burst can undergo matter oscillation before emerging out of the stellar envelope. Before reaching the detector on Earth, these neutrinos can undergo further vacuum oscillation and then Earth matter oscillation when crossing the diameter of the Earth. In the context of IceCube we study the Earth matter effect on neutrino flux in the detector. For the calculation of the track-to-shower ratio R in the IceCube, we have included the shadowing effect and the additional contribution from the muon track produced by the high energy tau lepton decay in the vicinity of the detector. We observed that R is different for different CP phases in vacuum but the matter effect suppresses these differences. We have also studied the behavior of R when the spectral index α varies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous years we have characterized the decrease in detection threshold afforded by correlation detection across an array or network when observations of a previous event provide an adequate template for signals from subsequent events located near the calibration event. Last year we examined two related issues: (1) the size of the source region calibration footprint afforded by a master event, and (2) the use of temporally incoherent detectors designed to detect the gross envelope structure of the signal to extend the footprint. In Case 1, results from the PETROBAR-1 marine refraction profile indicated that array correlation gain was usable at inter-source separations out to one or two wavelengths. In Case 2, we found that incoherent detectors developed from a magnitude 6 event near Svalbard were successful at detecting aftershocks where correlation detectors derived from individual aftershocks were not. Incoherent detectors might provide 'seed' events for correlation detectors that then could extend detection to lower magnitudes. This year we addressed a problem long known to limit the acceptance of correlation detectors in practice: the labor intensive development of templates. For example, existing design methods cannot keep pace with rapidly unfolding aftershock sequences. We successfully built and tested an object-oriented framework (as described in our 2005 proposal) for autonomous calibration of waveform correlation detectors for an array. The framework contains a dynamic list of detectors of several types operating on a continuous array data stream. The list has permanent detectors: beam forming power (STA/LTA) detectors which serve the purpose of detecting signals not yet characterized with a waveform template. The framework also contains an arbitrary number of subspace detectors which are launched automatically using the waveforms from validated power detections as templates. The implementation is very efficient such that the computational cost of adding subspace detectors was low. The framework contains a supervisor that oversees the validation of power detections, and periodically halts the processing to revise the portfolio of detectors. The process of revision consists of collecting the waveforms from all detections, performing cross-correlations pairwise among all waveforms, clustering the detections using correlations as a distance measure, then creating a new subspace detector from each cluster. The collection of new subspace detectors replaces the existing portfolio and processing of the data stream resumes. This elaborate scheme was implemented to prevent proliferation of closely-related subspace detectors. The method performed very well on several simple sequences: 2005 'drumbeat' events observed locally at Mt. St. Helens, and the 2003 Orinda, CA aftershock sequence. Our principal test entailed detection of the aftershocks of the San Simeon earthquake using the NVAR array; in this case, the system automatically detected and categorized approximately 2/3 of the events above magnitude 2.8.

58 GEOSCIENCES↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗

Neutron dose equivalent measured at the maze door with various openings for the jaws and MLC

Purpose: This study was undertaken to explore the effects of the jaws and the MLC openings on the neutron dose equivalent (DE) at the maze door and neutron flux at the patient plane. Methods: The neutron dose equivalent was measured at the maze entrance door of a 15 MV therapy linear accelerator room. All measurements were performed using various field sizes up to 40 cm x 40 cm. Activation detectors constructed from natural Indium (In) were exposed at Cd envelope to neutrons in order to estimate relative changes of epithermal neutron fluences in the patient plane. Results: Our study showed that the dose equivalent at the maze door is at the highest when the jaw are closed and that maximal jaws opening reduces the DE by more than 20%. The neutron dose equivalent at the maze door measured for radiation fields defined by jaws do not differ significantly from the DE measured when MLC determines the same size radiation field. The epithermal capture reaction rate measured using different jaw openings differs by approximately 10%. When an MLC leaf is inserted into a fixed geometry for one opening of the jaws, an increase of the epithermal neutron capture reaction rate in Indium activation detectors was observed. Conclusions: There is no significant difference in the neutron DE when MLC defines radiation field instead of jaws. This leads to the conclusion that the overall number of neutrons remains similar and it does not depend on how primary photon beam was stopped--by the jaws or the MLC. An increase of the fast neutron capture reaction rate when MLC leaves are inserted probably originates from the neutron scattering.

61 RADIATION PROTECTION AND DOSIMETRY↗

$\mathrm{REX}$: An analytical tool for reactor operating envelope expansion through fuel-clad thermo-mechanics

Here REX, an analytical reactor design tool for the identification and expansion of reactor operating envelopes, is introduced and detailed. Written in MATLAB, REX takes core geometries and axially discretized detector and depletion output from the Serpent neutron transport code and performs full-core, pin-specific thermal-hydraulic and thermo-mechanical calculations. REX identifies the operating envelopes of advanced, solid-fuel nuclear reactors on the basis of their fuel-cladding, fuel-gas, and coolant-cladding interfacial thermo-mechanics. It iteratively pushes coolant inlet temperatures and modifies fuel pin geometries to induce mechanical failure in their original cladding materials at the fullest extent of their fuel cycle lengths and permissible coolant inlet temperatures. It then attempts to expand their operating envelopes by determining the mechanical responses of alternative cladding materials under the same geometric conditions. The result of the REX calculation sequence is a set of 5-D variables describing the temperatures, pressures, geometries, and mechanics of the core as functions of assembly, fuel pin, axial zone, depletion step, and coolant inlet temperature for each candidate cladding material with the limiting fuel pin geometry for the original material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integration of the full-acceptance detector into the JLEIC

For physics requirements, the JLEIC (Jefferson Lab Electron Ion Collider) has a full-acceptance detector, which brings many new challenges to the beam dynamics integration. For example, asymmetric lattice and beam envelopes at interaction region (IR), forward detection, and large crossing angle with crab dynamics. Also some common problems complicate the picture, like coupling and coherent orbit from detector solenoid, high chromaticity and high multipole sensitivity from low beta-star at interaction point (IP), collision mode with different energy and ion species. Meanwhile, to get a luminosity level of a few 1033 cm-2sec-1, small ?* are necessary at the IP, which also means large ? in the final focus area, chromaticity correction sections, etc. This sets a constraint on the field quality of magnets in large beta areas, in order to ensure a large enough dynamic aperture (DA). In this context, limiting multipole components of magnets are surveyed to get a standard line. And continuously, multipole magnets as dedicated correctors are studied to provide semi-local corrections of specific multipole components beyond the standard line. This report will mention those contents.

Wei, G.H.↗

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett↗

Modelling CN Zeeman effect observations of the envelopes of a low-mass protostellar disc and a massive protostar

We use the POLARIS radiative transfer code to produce simulated circular polarization Zeeman emission maps of the cyanide (CN) J = 1–0 molecular line transition for two types of protostellar envelope magnetohydrodynamic simulations. Our first model is a low-mass disc envelope system (box length L = 200 au), and our second model is the envelope of a massive protostar (L = 104 au) with a protostellar wind and a CN-enhanced outflow shell. We compute the velocity-integrated Stokes I and V, as well as the implied V/I polarization percentage, for each detector pixel location in our simulated emission maps. Our results show that both types of protostellar environments are in principle accessible with current circular polarization instruments, with each containing swaths of envelope area that yield percentage polarizations that exceed the 1.8 percent nominal sensitivity limit for circular polarization experiments with the Atacama Large Millimeter/submillimeter Array. In both systems, high-polarization (≳1.8 percent) pixels tend to lie at an intermediate distance away from the central star and where the line-centre opacity of the CN emission is moderately optically thin (τLC ~ 0.1–1). Furthermore, our computed V/I values scale roughly with the density-weighted mean line-of-sight magnetic field strength, indicating that Zeeman observations can effectively diagnose the strength of envelope-scale magnetic fields. We also find that pixels with large V/I are preferentially co-located where the absolute value of the velocity-integrated V is also large, suggesting that locations with favourable percentage polarization are also favourable in terms of raw signal.

79 ASTRONOMY AND ASTROPHYSICS↗

A COMPREHENSIVE STUDY OF CLOSE DOUBLE WHITE DWARFS AS GRAVITATIONAL WAVE SOURCES: EVOLUTIONARY CHANNELS, BIRTH RATES, AND PHYSICAL PROPERTIES

Close double white dwarfs (CDWDs) are believed to dominate the Galactic gravitational wave (GW) radiation in the frequency range 10{sup -4} to 0.1 Hz, which will be detected by the Laser Interferometer Space Antenna (LISA) detector. The aim of this detector is to detect GW radiation from astrophysical sources in the universe and to help improve our understanding of the origin of the sources and their physical properties (masses and orbital periods). In this paper, we study the probable candidate sources in the Galaxy for the LISA detector: CDWDs. We use the binary population synthesis approach of CDWDs together with the latest findings of the synthesis models from Han, who proposed three evolutionary channels: (1) stable Roche lobe overflow plus common envelope (RLOF+CE), (2) CE+CE, and (3) exposed core plus CE. As a result, we systematically investigate the detailed physical properties (the distributions of masses, orbital periods, and chirp masses) of the CDWD sources for the LISA detector, examine the importance of the three evolutionary channels for the formation of CDWDs, and carry out Monte Carlo simulations. Our results show that RLOF+CE and CE+CE are the main evolutionary scenarios leading to the formation of CDWDs. For the LISA detectable sources, we also explore and discuss the importance of these three evolutionary channels. Using the calculated birth rate, we compare our results to the LISA sensitivity curve and the foreground noise floor of CDWDs. We find that our estimate for the number of CDWD sources that can be detected by the LISA detector is greater than 10,000. We also find that the detectable CDWDs are produced via the CE+CE channel and we analyze the fraction of the detectable CDWDs that are double helium (He+He), or carbon-oxygen plus helium (CO+He) WD binary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Radiochromic film imaging spectroscopy of laser-accelerated proton beams

This article reports on an experimental method to fully reconstruct laser-accelerated proton beam parameters called radiochromic film imaging spectroscopy (RIS). RIS allows for the characterization of proton beams concerning real and virtual source size, envelope- and microdivergence, normalized transverse emittance, phase space, and proton spectrum. This technique requires particular targets and a high resolution proton detector. Therefore thin gold foils with a microgrooved rear side were manufactured and characterized. Calibrated GafChromic radiochromic film (RCF) types MD-55, HS, and HD-810 in stack configuration were used as spatial and energy resolved film detectors. The principle of the RCF imaging spectroscopy was demonstrated at four different laser systems. This can be a method to characterize a laser system with respect to its proton-acceleration capability. In addition, an algorithm to calculate the spatial and energy resolved proton distribution has been developed and tested to get a better idea of laser-accelerated proton beams and their energy deposition with respect to further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions

The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.

47 OTHER INSTRUMENTATION↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗