Physical and Chemical Morphology of Passively Sampled Environmental Films

Environmental surface films are important mediators in the fate and transport of persistent organic pollutants (POP) via largely uncharacterized mechanisms. This work presents the first analysis of the physical and chemical morphology of passively sampled environmental films. The films are developed in urban, sub-urban, and metropolitan locations for timescales ranging from 1 to 52 weeks by exposing polished silicon wafers to collect passively deposited tropospheric particulate matter. The time-dependent spatial morphology of the films is analyzed by bright-field, scanning electron, and atomic force microscopies. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging data are analyzed to report the film’s chemical morphology and speciation. We find that the film matrix presents an extremely complex physical and chemical system. Deposited PM sizes span six orders of magnitude (millimeter to nanometer regimes), and surface coverages range from ca. 5 % for one week films and ca. 98 % for 52 week films. We observe significant amounts of mineral dust, biogenic organics, and occasional indications of flora growth (i.e., spores). The films exhibit nanoscale surface features indicative of small particulate depositions as well as films of (semi)volatile molecules. SIMS imaging reveals diverse and sometimes segregated chemical domains of hydrocarbons, inorganics, metals, and proteinaceous macromolecules. This work presents the first spatially resolved physical and chemical surface characterization of native environmental films, beginning a study of mechanisms by which these films form, persist, and mature in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

135 Cs/ 137 Cs isotopic composition of environmental samples across Europe: Environmental transport and source term emission applications

135 Cs/ 137 Cs isotopic analyses represent an important tool for studying the fate and transport of radiocesium in the environment; in this work the 135 Cs/ 137 Cs isotopic composition in environmental samples taken from across Europe is reported. Surface soil and vegetation samples from western Russia, Ukraine, Austria, and Hungary show consistent aged thermal fission product 135 Cs/ 137 Cs isotope ratios of 0.58 ± 0.01 (age corrected to 1/1/15), with the exception of one sample of soil-moss from Hungary which shows an elevated 135 Cs/ 137 Cs ratio of 1.78 ± 0.12. With the exception of the outlier sample from Hungary, surface soil/vegetation data are in quantitative agreement with values previously reported for soils within the Chernobyl exclusion zone, suggesting that radiocesium at these locations is primarily composed of homogenous airborne deposition from Chernobyl. Seawater samples taken from the Irish Sea show 135 Cs/ 137 Cs isotope ratios of 1.22 ± 0.11 (age corrected to 1/1/15), suggesting aged thermal fission product Cs discharged from Sellafield. Furthermore, the differences in 135 Cs/ 137 Cs isotope ratios between Sellafield, Chernobyl, and global nuclear weapons testing fallout indicate that 135 Cs/ 137 Cs isotope ratios can be utilized to discriminate between and track radiocesium transport from different nuclear production source terms, including major emission sources in Europe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Targeted quantification of functional enzyme dynamics in environmental samples for microbially mediated biogeochemical processes: Targeted quantification of functional enzyme dynamics

Microbially mediated biogeochemical processes are catalyzed by enzymes that control the transformation of carbon, nitrogen, and other elements in environment. The dynamic linkage between enzymes and biogeochemical species transformation has, however, rarely been investigated because of the lack of analytical approaches to efficiently and reliably quantify enzymes and their dynamics in soils and sediments. Herein, we developed a signature peptide-based technique for sensitively quantifying dissimilatory and assimilatory enzymes using nitrate-reducing enzymes in a hyporheic zone sediment as an example. Moreover, the measured changes in enzyme concentration were found to correlate with the nitrate reduction rate in a way different from that inferred from biogeochemical models based on biomass or functional genes as surrogates for functional enzymes. This phenomenon has important implications for understanding and modeling the dynamics of microbial community functions and biogeochemical processes in environments. Our results also demonstrate the importance of enzyme quantification for the identification and interrogation of those biogeochemical processes with low metabolite concentrations as a result of faster enzyme-catalyzed consumption of metabolites than their production. The dynamic enzyme behaviors provide a basis for the development of enzyme-based models to describe the relationship between the microbial community and biogeochemical processes.

Li, Minjing↗

Comparative Analysis of Corrinoid Profiles across Host-Associated and Environmental Samples

Vitamin B 12 (the cyanated form of cobalamin cofactors) is best known for its essential role in human health. In addition to its function in human metabolism, cobalamin also plays important roles in microbial metabolism and can impact microbial community function. Cobalamin is a member of the structurally diverse family of cofactors known as cobamides that are produced exclusively by certain prokaryotes. Cobamides are considered shared nutrients in microbial communities because the majority of bacteria that possess cobamide-dependent enzymes cannot synthesize cobamides de novo. Furthermore, different microbes have evolved metabolic specificity for particular cobamides, and therefore, the availability of cobamides in the environment is important for cobamide-dependent microbes. Determining the cobamides present in an environment of interest is essential for understanding microbial metabolic interactions. By examining the abundances of different cobamides in diverse environments, including 10 obtained in this study, we find that, contrary to its preeminence in human metabolism, cobalamin is relatively rare in many microbial habitats. Comparison of cobamide profiles of mammalian gastrointestinal samples and wood-feeding insects reveals that host-associated cobamide abundances vary and that fecal cobamide profiles differ from those of their host gastrointestinal tracts. Environmental cobamide profiles obtained from aquatic, soil, and contaminated groundwater samples reveal that the cobamide compositions of environmental samples are highly variable. As the only commercially available cobamide, cobalamin is routinely supplied during microbial culturing efforts. Furthermore, these findings suggest that cobamides specific to a given microbiome may yield greater insight into nutrient utilization and physiological processes that occur in these habitats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonparametric Multiparticle Set Methods for Interpreting Environmental Samples

Collection and analysis of environmental samples is commonly used by a range of stakeholders in nuclear safeguards and security contexts. While the ubiquity of samples and their transport in the environment allow regular collection, developing and demonstrating methods for analyzing these samples is difficult. In this work, an environmental sample consists of a set of one or more individual particles. Recent advances in reactor simulation have allowed us to generate data that are more representative of real-world environmental samples, enabling statistically defensible method development and testing. The most notable of these advances is a drastic increase in the number of material depletion regions, which allows our simulations to capture the variation in isotopic composition seen at length scales consistent with environmental samples. Traditional approaches for handling multiparticle samples treat each particle in the sample individually, estimating the quantity of interest (e.g., core-average burnup) resulting from measurement and analysis of signatures (e.g., nuclide assays) from each individual particle. Individual estimates are then averaged to generate a single estimate of the quantity of interest over the entire sample. In this presentation, we introduce two novel approaches for interpreting environmental samples that comprise of multiple particles: (1) the Quantile-Quantile Comparator, which uses a multivariate generalization of quantile-quantile plots for comparing unknown statistical distributions, and (2) the Set Transformer, an attention-based neural network module designed to model interactions among elements (particles) in the input set (sample). Statistically representative sampling cannot be guaranteed as samples are passively collected and are beholden to what particles are available in the environment. These new analysis methods for set-input problems are expected to be more robust than traditional approaches to issues of sampling bias where particles are not uniformly distributed throughout regions of interest, as well as generally outperform traditional approaches by jointly considering all elements in the set. We will present results comparing the performance of traditional single particle approaches and the novel Quantile-Quantile Comparator and Set Transformer for interpretation of simulated environmental samples.

Phathanapirom, Birdy↗

An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor accommodates many gas atmospheres, including reactive or corrosive gasses, but was designed specically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconguration. Using the reactor contributes over 85% less additional absorption compared to lling the STXM chamber with process gas, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

Environmental Molecular Sciences Laboratory↗

DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity to collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI), Office of Nonproliferation and International Security (NIS), National Nuclear Security Administration (NNSA).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extended Characterization of Chemical Processes in Hot Cells Using Environmental Swipe Samples

Environmental sampling is used extensively by the International Atomic Energy Agency (IAEA) for verification of information from State declarations or a facility’s design regarding nuclear activities occurring within the country or a specific facility. Environmental sampling of hot cells within a facility under safeguards is conducted using 10.2 cm x 10.2 cm cotton swipe material or cellulose swipes. Traditional target analytes used by the IAEA to verify operations within a facility include a select list of gamma-emitting radionuclides and total and isotopic U and Pu. Analysis of environmental swipe samples collected within a hot-cell facility where chemical processing occurs may also provide information regarding specific chemicals used in fuel processing. However, using swipe material to elucidate what specific chemical processes were/are being used within a hot cell has not been previously evaluated. Staff from Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) teamed to evaluate the potential use of environmental swipe samples as collection media for volatile and semivolatile organic compounds. This evaluation was initiated with sample collection during a series of Coupled End-to-End (CETE) reprocessing runs at ORNL. The study included measurement of gamma emitting radionuclides, total and isotopic U and Pu, and volatile and semivolatile organic compounds. These results allowed us to elucidate what chemical processes used in the hot cells during reprocessing of power reactor and identify other legacy chemicals used in hot cell operations which predate the CETE process.

Environmental Sampling↗

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector), ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing Reactor Operations from Realistic Simulated Environmental Samples: Combining High-Performance Computing and Data Analytics

Environmental sampling is a common technique employed by inspectors and facility operators in nuclear safeguards, proliferation detection, and process monitoring contexts. Interpreting measurements performed on samples or collections of samples and ensuring the information extracted is accurate and precise is difficult. To date, these analyses have relied on simulated data to enable systematic studies; however, these models are inherently limited by the fidelity of the models and the implicit spatial averaging of isotopic composition or other signatures of interest. To advance this capability, we have refined the spatial discretization and expanded the range of physics in the simulation codes we use to perform reactor simulations and depletion calculations. This allows us to generate data that are more representative of real environmental samples, especially for the length scale of the isotopic composition and associated variation. Accordingly, these new data allow a more realistic assessment of traditional and new data analytic analysis methods. Here we present motivation for developing reactor simulations using high-performance computing methods and resources, impacts of these new simulations on our assessment of data analysis and interpretation methods, and initial results of developing and systematically testing data analytic methods designed to overcome the challenges expected of real-world samples. We also quantify the performance of these analyses using defensible statistical methods.

Dayman, Ken J.↗

Report for Development of a Census Array and Evaluation of the Array to Detect Biothreat Agents and Environmental Samples for DHS

The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, Taqman PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. This report focuses on the design, testing and results of samples on the Census Array. We designed a Census/Detection Array to detect all sequenced viruses (including phage), bacteria (eubacteria), and plasmids. Family-specific probes were selected for all sequenced viral and bacterial complete genomes, segments, and plasmids. Probes were designed to tolerate some sequence variation to enable detection of divergent species with homology to sequenced organisms, and to be unique relative to the human genome. A combination of 'detection' probes with high levels of conservation within a family plus 'census' probes targeting strain/isolate specific regions enabled detection and taxonomic classification from the level of family down to the strain. The array has wider coverage of bacterial and viral targets based on more recent sequence data and more probes per target than other microbial detection/discovery arrays in the literature. We tested the array with purified bacterial and viral DNA/RNA samples, artificial mixes of known bacterial/viral samples, spiked DNA against complex background including BW aerosol samples and soil samples, and environmental samples to evaluate the array's sensitivity and forensic capability. The data were analyzed using our novel maximum likelihood software. For most of the organisms tested, we have achieved at least species level discrimination.

59 BASIC BIOLOGICAL SCIENCES↗

CABO-16S—a Combined Archaea, Bacteria, Organelle 16S rRNA database framework for amplicon analysis of prokaryotes and eukaryotes in environmental samples

Abstract Identification of both prokaryotic and eukaryotic microorganisms in environmental samples is currently challenged by the need for additional sequencing to obtain separate 16S and 18S ribosomal RNA (rRNA) amplicons or the constraints imposed by “universal” primers. Organellar 16S rRNA sequences are amplified and sequenced along with prokaryote 16S rRNA and provide an alternative method to identify eukaryotic microorganisms. CABO-16S combines bacterial and archaeal sequences from the SILVA database with 16S rRNA sequences of plastids and other organelles from the PR2 database to enable identification of all 16S rRNA sequences. Comparison of CABO-16S with SILVA 138.2 results in equivalent taxonomic classification of mock communities and increased classification of diverse environmental samples. In particular, identification of phototrophic eukaryotes in shallow seagrass environments, marine waters, and lake waters was increased. The CABO-16S framework allows users to add custom sequences for further classification of underrepresented clades and can be easily updated with future releases of reference databases. Addition of sequences obtained from Sanger sequencing of methane seep sediments and curated sequences of the polyphyletic SEEP-SRB1 clade resulted in differentiation of syntrophic and non-syntrophic SEEP-SRB1 in hydrothermal vent sediments. CABO-16S highlights the benefit of combining and amending existing training sets when studying microorganisms in diverse environments.

Eitel, Eryn M. (ORCID:0009000723919297)↗

Incorporation of New, Automated Environmental Sampling Systems into Safeguards Approaches

The three technologies—tamper resistant/indicating aerosol contaminant extractor (TRI‐ACE), laser ablation laser absorbance ratio spectrometry‐environmental sampling (LAARS‐ES), and LAARS‐destructive assay (DA)—have the potential to revolutionize aspects of sampling at gas centrifuge enrichment plants (GCEPs). The environmental sampling capabilities of TRI‐ACE and LAARS‐ES have the ability to provide unattended and remote monitoring equipment at a GCEP that constantly samples the environment for anomalous uranium particles that are indicative of clandestine enrichment to highly enriched uranium (HEU).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

A Discussion of Procedures and Equipment for the Comprehensive Test Ban Treaty On-Site Inspection Environmental Sampling and Analysis

This paper is intended to serve as a scientific basis to start discussions of the available environmental sampling techniques and equipment that have been used in the past that could be considered for use within the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) on-site inspections (OSI). This work contains information on the techniques, equipment, costs, and some operational procedures associated with environmental sampling that have actually been used in the past by the United States for the detection of nuclear explosions. This paper also includes a discussion of issues, recommendations, and questions needing further study within the context of the sampling and analysis of aquatic materials, atmospheric gases, atmospheric particulates, vegetation, sediments and soils, fauna, and drill-back materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗