Search NASA⌕ Search

SEARCH · Search NASA

Results for “ethanol separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microchip Non-Aqueous Capillary Electrophoresis (MicronNACE) Method to Analyze Long-Chain Primary Amines

A protocol was developed as a first step in analyzing the complex organic aerosols present on Saturn's moon Titan, as well as the analogues of these aerosols (tholins) made on Earth. Labeling of primary amines using Pacific Blue succinimidyl ester is effected in ethanol with 25 mM triethylamine to maintain basic conditions. This reaction is allowed to equilibrate for at least one hour. Separation of the labeled primary amines is performed in ethanol with 1.05 M acetic acid, and 50 mM ammonium acetate in a commercial two-layer glass device with a standard crossmicrochannel measuring 50 microns wide by 20 microns deep. Injection potentials are optimized at 2 kV from the sample (negative) to the waste well (positive), with slight bias applied to the other two wells ( 0.4 and 0.8 V) to pinch the injection plug for the 30-s injection. Separation is performed at a potential of 5 kV along the channel, which has an effective separation distance of 7 cm. The use of ethanol in this method means that long-chain primary amines can be dissolved. Due to the low pH of the separation buffer, electro-osmotic flow (EOF) is minimized to allow for separation of both short-chain and longchain amines. As the freezing point of ethanol is much lower than water, this protocol can perform separations at temperatures lower than 0 C, which would not be possible in aqueous phase. This is of particular importance when considering in situ sampling of Titan aerosols, where unnecessary heating of the sample (even to room temperature) would lead to decomposition or unpredictable side reactions, which would make it difficult to characterize the sample appropriately.

Willis, Peter A.↗

FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials

The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.

Mattson, C. B.↗

ECUT: Energy Conversion and Utilization Technologies program biocatalysis research activity. Potential membrane applications to biocatalyzed processes: Assessment of concentration polarization and membrane fouling

Separation and purification of the products of biocatalyzed fermentation processes, such as ethanol or butanol, consumes most of the process energy required. Since membrane systems require substantially less energy for separation than most alternatives (e.g., distillation) they have been suggested for separation or concentration of fermentation products. This report is a review of the effects of concentration polarization and membrane fouling for the principal membrane processes: microfiltration, ultrafiltration, reverse osmosis, and electrodialysis including a discussion of potential problems relevant to separation of fermentation products. It was concluded that advanced membrane systems may result in significantly decreased energy consumption. However, because of the need to separate large amounts of water from much smaller amounts of product that may be more volatile than wate, it is not clear that membrane separations will necessarily be more efficient than alternative processes.

Ingham, J. D.↗

The determination of ethanol in blood and urine by mass fragmentography

A mass fragmentographic technique for a rapid, specific and sensitive determination of ethanol in blood and urine is described. A Varian gas chromatograph coupled through an all-glass membrane separator to a Finnigan quadripole mass spectrometer and interfaced to a computer system is used for ethanol determination in blood and urine samples. A procedure for plotting calibration curves for ethanol quantitation is also described. Quantitation is achieved by plotting the peak area ratios of undeuterated-to-deuterated ethanol fragment ions against the amount of ethanol added. Representative results obtained by this technique are included.

Pereira, W. E.↗

Rodent Research on the International Space Station - A Look Forward

Rodent Research on the International Space Station (ISS) is one of the highest priority science activities being supported by NASA and is planned for up to two flights per year. The first Rodent Research flight, Rodent Research-1 (RR-1) validates the hardware and basic science operations (dissections and tissue preservation). Subsequent flights will add new capabilities to support rodent research on the ISS. RR-1 will validate the following capabilities: animal husbandry for up to 30 days, video downlink to support animal health checks and scientific analysis, on-orbit dissections, sample preservation in RNA. Later and formalin, sample transfer from formalin to ethanol (hindlimbs), rapid cool-down and subsequent freezing at -80 of tissues and carcasses, sample return and recovery. RR-2, scheduled for SpX-6 (Winter 20142015) will add the following capabilities: animal husbandry for up to 60 days, RFID chip reader for individual animal identification, water refill and food replenishment, anesthesia and recovery, bone densitometry, blood collection (via cardiac puncture), blood separation via centrifugation, soft tissue fixation in formalin with transfer to ethanol, and delivery of injectable drugs that require frozen storage prior to use. Additional capabilities are also planned for future flights and these include but are not limited to male mice, live animal return, and the development of experiment unique equipment to support science requirements for principal investigators that are selected for flight. In addition to the hardware capabilities to support rodent research the Crew Office has implemented a training program in generic rodent skills for all USOS crew members during their pre-assignment training rotation. This class includes training in general animal handling, euthanasia, injections, and dissections. The dissection portion of this training focuses on the dissection of the spleen, liver, kidney with adrenals, brain, eyes, and hindlimbs. By achieving and maintaining proficiency in these basic skills as part of the nominal astronaut training curriculum this allows the rodent research program to focus the mission specific crew training on scientific requirements of research and operations flow.

Experimental capabilities↗

Supercritical fluid extraction and characterization of lipids from algae Scenedesmus obliquus

Lipids were extracted from a protein concentrate of green algae (Scenedesmus obliquus), using a one-step supercritical carbon dioxide extraction procedure in presence of ethanol as an entrainer, and were characterized. The compositions of neutral lipids, glycolipids, and phospholipids, separated into individual components by column, thin-layer, and gas-liquid chromatography procedures, are presented. Fatty acid composition patterns indicated that the major fatty acids were 16:0, 16:1, 16:2, 16:3, 16:4, 18:1, 18:2, and 18:3. The lipids of S. obliquus were found to contain relatively high concentrations of polyunsaturated fatty acids and essential fatty acids.

Choi, K. J.↗

Toughened uni-piece fibrous insulation

A porous body of fibrous, low density silica-based insulation material is at least in part impregnated with a reactive boron oxide containing borosilicate glass frit, a silicon tetraboride fluxing agent and a molybdenum silicide emittance agent. The glass frit, fluxing agent and emittance agent are separately milled to reduce their particle size, then mixed together to produce a slurry in ethanol. The slurry is then applied to the insulation material and sintered to produce the porous body.

Leiser, Daniel B↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Supercritical Water Oxidation: Testing of Ersatz Wastewater

Supercritical Water Oxidation (SCWO) technology is under consideration by NASA for treatment of wastewater and other wet waste streams. The dramatic changes in water's thermophysical properties near its critical point (374◦C and 22 MPa) result in nearly complete solubility of organics and gases. The absence of inter–phase transport processes and phase separation results in dramatically reduced reaction timescales and the elimination of complications of two–phase transport and processing in reduced gravity. Other advantages are that the product streams are microbially inert,benign, amenable to resource recovery and organic waste. This paper first described the design and construction of tubular SCWO reactor built at NASA Glenn. It consists of separate wastewater and oxidizer inlets, which are independently heated and pressurized to conditions approaching the critical point of water. These flows enter a reactor chamber having a volume of 62 ml. The reactor section is heated to the desired temperature in the range of 450 ◦C – 650 ◦C. A pressure regulator maintains the operating pressure nominally between 27.6 MPa and 28.3 MPa. The reacted fluid is captured downstream of the pressure regulator during an experiment run. A separate vent line may also be used for collection of the effluent. Next, the results of SCWO experiments using both a representative organic (ethanol) as well as a wastewater simulant provided by NASA Ames are presented. Raman analysis of the pre–reacted and post–reacted solutions are presented. Finally, initial efforts on supplementary chemical kinetics modeling of ethanol oxidation with and without inclusion of a nitrogenous compounds (ammonia) are presented.

Michael C Hicks↗

Gauche Ethyl Alcohol: Laboratory Assignments and Interstellar Identification

Ethyl alcohol (ethanol) is known to possess a pair of closely spaced excited torsional substates (gauche+, gauche-) at an energy of approximately 57 K above the ground (trans) torsional substate. We report an extended analysis of some gauche - gauche+ Q-branch ((Delta)J = 0) transitions with a three-substate fixed frame axis method (FFAM) Hamiltonian. Our approach accounts for complex trans-gauche interactions for the first time. In addition, we are able to obtain intensities for perturbed rotational transitions, and to determine the trans to gauche+ separation to be 1185399.1 MHz. A complete ground state rotational-torsional partition function accounting for the previously neglected gauche substates is presented. Based on our analysis, a total of 14 U lines obtained towards Orion KL can now be assigned to gauche substates of ethanol. Analysis of these lines yields a rotational temperature of 223 K and a total (trans + gauche) column density of 7.0 x 10(exp 15)/sq cm. The column density is in reasonable agreement with the recent value of 2-3 x 10(exp 15)/sq cm based on observations of trans-ethanol by Ohishi et al., although there is some disparity in the rotational temperatures. Eight additional U lines in the literature are assigned to transitions of gauche ethanol.

Pearson, J. C.↗

Fluid flow in solidifying monotectic alloys

Use of a two-wavelength holographic technique results in a simultaneous determination of temperature and composition profiles during directional solidification in a system with a miscibility gap. The relationships among fluid flow, phase separation, and mass transport during the solidification of the monotectic alloy are discussed. The primary sources of fluid motion in this system are buoyancy and thermocapillary forces. These forces act together when phase separation results in the formation of droplets (this occurs at the solid-liquid interface and in the bulk melt). In the absence of phase separation, buoyancy results from density gradients related to temperature and compositional gradients in the single-phase bulk melt. The effects of buoyancy are especially evident in association with water- or ethanol-rich volumes created at the solid-liquid growth interface.

Ecker, A.↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

In-situ Raman Instrumentation and Measurements in Supercritical Water Oxidation Systems

Due to the advent of recent advances in reactor designs and operational procedures, renewed attention has been given to a host of supercritical water oxidation (SCWO) technology applications. This includes resource recovery, water reclamation, and solid waste destruction. SCWO is often recognized as a “green technology” because of its ability to extract useful energy while producing benign products from environmentally challenging waste streams (e.g., wet organic wastes, pharmaceutical wastes, military wastes). The present work was motivated by NASA’s interests in solid waste management and water recovery for long-duration space missions. To that end, the main focus of this paper is to present work on characterizing the behavior of supercritical water oxidation systems utilizing state of the art laser Raman spectroscopy. The main benefit of Raman diagnostics is its ability to identify chemical composition and to measure concentrations of the compounds involved in the reaction. Two separate Raman systems for SCWO measurements that have been developed for this study will be described. The first system is a 2-D traversing system useful for making in-situ measurements in conditions where spatial gradients of species and temperature are important and has been successfully utilized in making species (ethanol, oxygen, water, nitrogen and carbon dioxide) concentrations and temperature measurements in ethanol hydrothermal jet flames. The second system is a packaged modular Raman probe unit for portable deployment to different reactors and is more suitable for relatively homogeneous systems such as a batch reactor. The design, development, and examples of obtained results from both systems will be presented for various reactant streams. Reaction rate and fuel conversion estimates from chemistry models will also be presented.

supercritical water oxidation↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

Olivine Dissolution and Formation of Secondary phases in Ultramafic Soils

Introduction: Olivine has been proposed as an indicator for the duration of water-rock interaction within Martian rocks and sediments [1-3]. The use of olivine as a mineralogical indicator for past aqueous alteration on Mars requires interpretation of a complex combination of factors including pH, temperature, and composition [5,6]. Here, we examine the persistence of natural olivine within terrestrial ultramafic soils (Fe/Mg-rich, Al-poor) developing under different climatic conditions and the incipient dissolution of emplaced forsterite (Fo) and fayalite (Fa) surfaces to investigate environmental effects on incipient olivine dissolution, olivine persistence in soils, and formation of secondary phases. Methods: Field Sites. We examined olivine weathering and secondary material formation in ultramafic soils at 6 sites in the Klamath Mountains (KM) of northern California with a mean annual temperature of ~12.8℃ and precipitation of ~55.7-95.4 cm/year [7], and soil pH of ~6.5-7.3; 4 sites in the Tablelands (TB) of Newfoundland, Canada with a mean annual temperature of <3.9℃ and precipitation of ~120.0 cm/year [8], and soil pH of ~7.7; and at 3 sites at Pickhandle Gulch (PG), Nevada with a mean annual temperature of ~14.4℃ and precipitation of ~14.1 cm/year [7], and soil pH of ~8.5. Sampling sites span an age range of ~12.1-50+ kya in the Klamath Mountains [9,10] and ~13-30 kya in the Tablelands [11]. Pickhandle Gulch sites are undated. Parent Material and Soil Analyses. Polished thin sections of bulk soil prepared by Wagner Petrographic, Inc were carbon-coated and analyzed on a JEOL 2100 SEM in back-scattered electron mode in the EMIL lab at UNLV and at the 13-ID-E synchrotron beamline at Argonne National Laboratory using µXRF, µXRD, and XAS. Soil and parent material samples were powdered in a Fritsch pulverisette and analyzed by XRD and soil by VNIR. Soil preparation is further described in [12]. Disk Preparation, Burial, and Collection. Fo disks were cut from a column prepared via hot-pressing and Fa disks by sintering synthetic fayalite powder, see [13] for detail. Disks were polished to a 0.25-micron level with diamond grit. Disks were buried in 3 KM soils, 4 TB soils, and 3 PG soils, collected after exactly 365 days, and washed gently with 100% reagent grade ethanol to remove potential adhered soil material. Weathered disks and soil samples were stored in a -20℃ freezer until analysis. Unaltered control disks prepared identically to the buried disks were stored at -20℃ for the duration of the experiment. Disk Analyses. One Fo and Fa disk from each climate zone was analyzed on a variable pressure Zeiss Supra 40VP SEM at Northern Arizona University. A separate Fo and Fa disk from each climate zone was analyzed by XPS using a Physical Electronics VersaProbe II at the Penn State Univ. Materials Characterization Lab after a Na-dodecyl sulfate wash and ozonation to remove carbon contamination as in [14]. VNIR measurements were conducted at Johnson Space Center using an ASD FieldSpec3 under ambient lab conditions on a separate Fo and Fa disk from each climate zone. One separate Fo and Fa control sample was analyzed for each technique for comparison with weathered samples. XPS uncertainty was determined from 5 repeat measurements on controls. Results: Bedrock and Soil Results Olivine is present in the parent material in the KM and TB. Olivine is found in ~12.1 ka KM soils but is absent from all older soils, while persisting into the oldest (>20 ka) TB soil (Figure 1). In both locations, olivine is found as cores surrounded by a serpentine rind (Figure 2). VNIR spectra from the analyzed soils possess strong OH-associated spectral features at ~2.33 µm indicating the presence of Mg-rich phyllosilicates as well as ferric-oxide features at ~0.92 µm in the KM (Figure 3). Primary crystalline silicate grains mostly incorporate Fe2+, while poorly crystalline weathering rinds are best fit by ferric oxide XAS standards (Figure 4). µXRF also shows that Fe and Ni concentrate in weathering rinds and Cr remains within interior silicate grains (Figure 4). Buried Sample Results All Fo surfaces exhibited formation of dissolution features including shallow pitting not observed on controls. Dissolution features were most visually widespread on the KM disk (Figure 5). Leaching of Mg from KM and TB Fo disks was evident from <1.6 Mg/Si ratios measured by XPS (Figure 6). Fe-rich precipitates in SEM (Figure 5) and Fe presence in XPS scans (Figure 6) indicate Fe deposition onto KM and TB Fo disk surfaces. The appearance of a spectral feature at 0.55 µm in the VNIR spectra from the TB Fo suggests this Fe is ferric (Figure 7). The PG Fo appears least altered, with minimal formation of dissolution features in SEM (Figure 5), a Mg/Si ratio inconsistent with leaching (~2) (Figure 6), and VNIR spectra almost identical to the control sample. Analysis of Fa surfaces is ongoing. The higher temperatures and more acidic pH in the KM soils likely drive the faster dissolution of the Fo disks described above. While the TB soils experience greater precipitation than in the KM, the cooler temperatures and more basic soil pH facilitate observable but more limited alteration. The dry climate and basic soil pH at PG lead to minimal dissolution of the PG disk surfaces.

A D Feldman↗

The Development of an Edible Peanut Protein Film

The peanut is one of the crops chosen for use in NASA's Advanced Life Support Program (ALS). The peanut is a source of both oil and protein. After oil is extracted from the peanut, a protein rich flour remains. An edible peanut protein film is one use for this flour. Two types of film are developed for this study, one set of film contains 10% fat while the other set contains no fat. For film without fat the defatting of the peanut by the Soxhlet method is the first step in the manufacturing process of the film. Secondly, the protein is precipitated at its isoelectric point (pH 4.5) and centrifuged to separate the protein from the non-protein. After freeze-drying the protein it is milled in a ceramic ball mill to decrease particle size and sifted through a series of sieves to determine particle size distribution. Those particles retained on the 100 mesh sieves are utilized for film formation. Larger particles are re-ground and sifted. Five grams of protein is mixed with 50 mL of distilled water, 70 mL of 80% ethanol, 15 mL of 6N ammonium hydroxide and a plasticizer. This mixture is heated for 30 minutes until the temperature reaches 70 C. The mixture is then poured onto a level Teflon coated glass surface. After allowing the film to form overnight under a ventilation hood, it is manually removed from the plate. The processes and methods adopted have created flexible films of uniform thickness that are free of air bubbles. Thickness of films made from defatted peanut protein and partially defatted peanut protein were 0.10 Lm and 0.13 Lm respectively. Films with natural peanut fat are approximately three times as flexible and almost four times as strong as the films made without fat. Further research will be performed to evaluate its mechanical properties. This paper will greatly contribute to food preservation and waste management. Potential applications of this film are edible/biodegradable containers, wrapping for food preservation (against water, oxygen and oil), storage packets for seasonings or other ingredients and encapsulation for pharmaceutical use.

Patrick, N.↗

Microgravity Compatible Reagentless Instrumentation for Detection of Dissolved Organic Acids and Alcohols in Potable Water

The Organic Acid and Alcohol Monitor (OAAM) program has resulted in the successful development of a computer controlled prototype analyzer capable of accurately determining aqueous organic acids and primary alcohol concentrations over a large dynamic range with high sensitivity. Formic, acetic, and propionic acid were accurately determined at concentrations as low as 5 to 10 micrograms/L in under 20 minutes, or as high as 10 to 20 mg/L in under 30 minutes. Methanol, ethanol, and propanol were determined at concentrations as low as 20 to 100 micrograms/L, or as high as 10 mg/L in under 30 minutes. Importantly for space based application, the OAAM requires no reagents or hazardous chemicals to perform these analyses needing only power, water, and CO2 free purge gas. The OAAM utilized two membrane processes to segregate organic acids from interfering ions. The organic acid concentration was then determined based upon the conductiometric signal. Separation of individual organic acids was accomplished using a chromatographic column. Alcohols are determined in a similar manner after conversion to organic acids by sequential biocatalytic and catalytic oxidation steps. The OAAM was designed to allow the early diagnosis of under performing or failing sub-systems within the Water Recovery System (WRS) baselined for the International Space Station (ISS). To achieve this goal, several new technologies were developed over the course of the OAAM program.

Akse, James R.↗