Search NASA⌕ Search

SEARCH · Search NASA

Results for “exclusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nanofluidic Size-Exclusion Chromatograph

Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

Feldman, Sabrina↗

Nano-fabricated size exclusion chromatograph

This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

nanofluids lab-on-a-chip chromatograph separation↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗

Detection of Vegetation Trends in Highly Variable Environments After Grazing Exclusion in Mongolia

Aims: Environmental variability (e.g. in precipitation) has a large effect on vegetation dynamics, and this often makes it difficult to assess the recovery of vegetation after a disturbance. In this study, we assessed vegetation recovery trends in response to grazing exclusion while considering for the annual environmental variability. Location: Two regions with highly variable precipitation: a steppe near Mandalgobi, in Mongolia's Central Gobi province, and a desert steppe near Bulgan, in Mongolia's South Gobi province. Methods: Changes in vegetation were observed along grazing gradients at the above two sites, and vegetation thresholds were identified. We established reference plots in pre-threshold areas along the grazing gradients. We removed the impact of livestock grazing at various locations along the grazing gradients by establishing exclosures, and investigated vegetation from 2005 to 2013. We developed a smoothed hierarchical model within a Bayesian framework, and examined the effect of grazing exclusion on vegetation, focusing especially on the extent of grass cover recovery. In addition, we compared soil nutrient conditions in the reference plots and inside and outside each exclosure along the grazing gradients. Results: Temporal trends in the cover of perennial grass in each plot inside and outside of the exclosures largely coincided, irrespective of grazing intensity, and exclosure had no effect (Bulgan) or a negative effect (Mandalgobi) on vegetation recovery. Soil nutrient content was not significantly affected by exclosure at a given distance from the grazing source, but decreased significantly with decreasing grazing intensity. Thus, recovery of the land from a post-threshold state may not be apparent even after 9 yr of grazing exclusion in environments with highly variable precipitation. Conclusion: The effect of exclosure duration on perennial grass cover was limited, even after controlling for environmental variability. Once a vegetation threshold has been crossed, merely removing livestock from the landscape may not be sufficient for that area to recover.

Bayesian statistics;Drought;Environmental variabil↗

Exclusive-or logic circuit has useful properties

Single, simple exclusive-or logic connective eliminates excessive hardware and the number of interconnections between logic modules. This circuit performs the necessary switching for the exclusive-or operation and amplifies, restores, and inverts the signal.

Batte, W. G.↗

Exclusive Reactions Involving Pions and Nucleons

The HZETRN code requires inclusive cross sections as input. One of the methods used to calculate these cross sections requires knowledge of all exclusive processes contributing to the inclusive reaction. Conservation laws are used to determine all possible exclusive reactions involving strong interactions between pions and nucleons. Inclusive particle masses are subsequently determined and are needed in cross-section calculations for inclusive pion production.

Norbury, John W.↗

Evidence for exclusively inorganic formation of magnetite in Martian meteorite ALH84001

Magnetite crystals produced by terrestrial magnetotactic bacterium MV-1 are elongated on a [111] crystallographic axis, in a so-called truncated hexa-Octahedral shape. This morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes). A subpopulation of magnetite crystals associated with carbonate globules in Martian meteorite ALH84001 is reported to have this morphology, and the observation has been taken as evidence for biological activity on Mars. In this study, we present evidence for the exclusively inorganic origin of [111]-elongated magnetite crystals in ALH84001. We report three-dimensional(3-D) morphologies for approx.1000 magnetite crystals extracted from: (1) thermal decomposition products of Fe-rich carbonate produced by inorganic hydrothermal precipitation in laboratory experiments; (2) carbonate globules in Martian meteoriteeALH84001; and (3) cells of magnetotactic bacterial strain MV-1. The 3-D morphologies were derived by fitting 3-D shape models to two-dimensional bright-field transmission-electron microscope (TEAM) images obtained at a series of viewing angles. The view down the {110} axes closest to the [111] elongation axis of magnetite crystals ([111]x{110) not equal to 0) provides a 2-D projection that uniquely discriminates among the three [111]-elongated magnetite morphologies found in these samples: [111]-elongated truncated hexaoctahedron ([111]-THO), [111]-elongated cubo-octahedron ([111]-ECO), and [111]-elongated simple octahedron ([111]-ESO). All [111] -elongated morphologies are present in the three types of sample, but in different proportions. In the ALH84001 Martian meteorite and in our inorganic laboratory products, the most common [111]-elongated magnetite crystal morphology is [111]-ECO. In contrast, the most common morphology for magnetotactic bacterial strain MV-1 is [111]-THO. These results show that: (1) the morphology of [111]-elongated magnetite crystals associated with the carbonate globules in Martian meteorite ALH84001 is replicated by an inorganic process; and (2) the most common crystal morphology for biogenic (MV-1) magnetite is distinctly different from that in both ALH84001 and our inorganic laboratory products. Therefore, [111]-elongated magnetite crystals in ALH84001 do not constitute, as previously claimed, a robust biosignature and, in fact, an exclusively inorganic origin for the magnetite is fully consistent with our results. Furthermore, the inorganic synthesis method, i.e., the thermal decomposition of hydrothermally precipitated Fe-rich carbonate, is a process analogue for formation of the magnetite on Mars. Namely, precipitation of carbonate globules from carbonate-rich hydrothermal solutions followed at some later time by a thermal pulse, perhaps in association with meteoritic impact or volcanic processes on the Martian surface.

Golden, D. C.↗

Nanofluidic size exclusion chromatograph for in site macrometer analyses

We are developing a nanofluidic size exclusion chromatograph system that can be incorporated into a miniature lab-on-a-chip devices which will provide detailed information on the geochemical and biological history of soil, ice, and water samples by identifying and qualifying a broad range of macromolecular polar and nonpolar organic compounds.

size exclusion chromatograph↗

On-Orbit Measurements of Solar Exclusion Angle for Modular Agile Scalable Optical Terminal (MAScOT) on the ILLUMA-T Mission

The Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) optical communications payload operated on the International Space Station (ISS) for 8 months, concluding in June 2024. ILLUMA-T made the ISS the first space-based user to communicate with NASA’s Laser Communications Relay Demonstration (LCRD). ILLUMA-T was also the first flight demonstration of the Modular, Agile, Scalable Optical Terminal (MAScOT) which will also be used in the Orion Artemis II Optical Communications (O2O) program, where it will provide an optical communications link for the crew aboard the Artemis II mission. Often optical and radio frequency communications systems have outages when they are pointing close to the Sun, where unwanted incident and scattered solar energy significantly reduces or prohibits operations. The MAScOT was designed to reduce the impact of any solar scatter through optical design, material choices, surface treatments and high cleanliness levels. Based on optical scattering models, a solar exclusion angle of 10 degrees was established for ILLUMA-T. This paper presents optical scattering modeling predictions, pre-launch laboratory testing results, and on-orbit measurements of solar scatter at angles ranging from 3 to 25 degrees.

optical communications↗

User Manual for GERT EXCLUSIVE-OR Program

This report describes the procedures for using digital computer programs for analyzing GERT networks which contain nodes of the EXCLUSIVE-OR type and branches which have both a probability and a time associated with them. The time associated with a branch can be a random variable. The program calculates the probability, the expected time and the variance in the time to go from each source node of the GERT network to each sink node. Programs have been written in FORTRAN II and FORTRAN IV and have been exercised on the IBM 1130, GE 225 and CDC 3400 computers. This report details the operating procedures for using these programs. Four examples are included to illustrate the important facets involved in using the programs. Special options included in the program are: (1) printout of all loops and paths associated with the network; and (2) deletion of loops that have a probability of occurrence less than a value specified by the user. The program described in this report has been submitted to COSMIC.

Ishmael, Phillip C.↗

Implementing Exclusive-OR Logic

Two integrated circuits, BCD-to-decimal decoder and four-input NAND gate, form basic four, input XOR circuit. Multiple-input exclusive-OR logic is implemented by combining several basic elements. 16-input XOR gate is assembled from five NAND gates and five decoders. Same principle extended to handle more inputs.

Hough, M. E.↗

Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography

Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.

Jones, W. R., Jr.↗

Fault detection and exclusion in multisensor navigation systems

In order for a multisensor navigation system to meet integrity requirements, there must be a way of detecting erroneous measurements, using only data from those measurements. This can be accomplished using a parity space estimation algorithm. Erroneous measurements must then be removed from the position solution; the entire process is called fault detection and exclusion (FDE). A baseline FDE algorithm has been determined, and is capable of working in real time on present affordable hardware.

Bernath, Gregory N.↗

Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

Ewing, Felecia↗