Search NASA⌕ Search

SEARCH · Search NASA

Results for “expansion plug test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress $\sigma_\theta$ in the tested ring specimen. A scaling factor called $\chi$-factor is defined to correlate the ring load F ring into hoop stress $\sigma_\theta$, and written as $\sigma_\theta = \chi \frac{F_{ring}} {tl}$. The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.

expansion plug test↗

Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.

expansion plug test↗

The Development of Expansion Plug Wedge Test for Clad Tubing Structure Mechanical Property Evaluation

To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of shocks on film cooling of a full scale turbojet exhaust nozzle having an external expansion surface

Experimental film cooling data obtained during exploratory testing with an axisymmetric plug nozzle having external expansion and installed on an afterburning turbojet engine in an altitude test facility is presented. The shocks and local hot gas stream conditions had a marked effect on film cooling effectiveness. An existing film cooling correlation was adequate at some operating conditions but inadequate at other conditions such as in separated flow regions resulting from shock boundary layer interactions.

Straight, D. M.↗

Effect of shocks on film cooling of a full scale turbojet exhaust nozzle having an external expansion surface

Cooling is one of the critical technologies for efficient design of exhaust nozzles, especially for the developing technology of nonaxisymmetric (2D) nozzles for future aircraft applications. Several promising 2D nozzle designs have external expansion surfaces which need to be cooled. Engine data are scarce, however, on nozzle cooling effectiveness in the supersonic flow environment (with shocks) that exists along external expansion surfaces. This paper will present experimental film cooling data obtained during exploratory testing with an axisymmetric plug nozzle having external expansion and installed on an afterburning turbojet engine in an altitude test facility. The data obtained shows that the shocks and local hot gas stream conditions have a marked effect on film cooling effectiveness. An existing film cooling correlation is adequate at some operating conditions but inadequate at other conditions such as in separated flow regions resulting from shock-boundary-layer interactions.

Straight, D. M.↗

Altitude Compensating Nozzle Cold Flow Test Results

A suite of four altitude compensating nozzle (ACN) concepts were evaluated by NASA MSFC in the Nozzle Test Facility. The ACN concepts were a dual bell, a dual expander, an annular plug nozzle and an expansion deflection nozzle. Two reference bell nozzles were also tested. Axial thrust and nozzle wall static pressures were measured for each nozzle over a wide range of nozzle pressure ratios. The nozzle hardware and test program are described. Sample test results are presented.

Ruf, J. H.↗

Generation 1.5 High Speed Civil Transport (HSCT) Exhaust Nozzle Program

The objective of this program was to conduct an experimental and analytical evaluation of low noise exhaust nozzles suitable for future High-Speed Civil Transport (HSCT) aircraft. The experimental portion of the program involved parametric subscale performance model tests of mixer/ejector nozzles in the takeoff mode, and high-speed tests of mixer/ejectors converted to two-dimensional convergent-divergent (2-D/C-D), plug, and single expansion ramp nozzles (SERN) in the cruise mode. Mixer/ejector results show measured static thrust coefficients at secondary flow entrainment levels of 70 percent of primary flow. Results of the high-speed performance tests showed that relatively long, straight-wall, C-D nozzles could meet supersonic cruise thrust coefficient goal of 0.982; but the plug, ramp, and shorter C-D nozzles required isentropic contours to reach the same level of performance. The computational fluid dynamic (CFD) study accurately predicted mixer/ejector pressure distributions and shock locations. Heat transfer studies showed that a combination of insulation and convective cooling was more effective than film cooling for nonafterburning, low-noise nozzles. The thrust augmentation study indicated potential benefits for use of ejector nozzles in the subsonic cruise mode if the ejector inlet contains a sonic throat plane.

Thayer, E. B.↗

Ceramic Plugs for Deep Borehole Seals - 17316

In the deep borehole nuclear waste disposal concept, waste packages are emplaced deep in crystalline rock formations under conditions of high pressures, high mineral content water, and elevated temperatures. Well seals and plugs must perform for thousands of years. A novel ceramic plug system under development capitalizes on the thermal energy of thermite mixtures and engineered additives to react and form ceramic-like plugs in place with favorable structural, flow, and geochemical properties. Depending on the ingredients, the reaction can produce aluminosilicates, plagioclase feldspars, or other combinations in crystalline or amorphous forms. Normative mineralogy techniques were applied to predict product mineralogy and evaluate compatibility with host rocks, and showed they are comparable to igneous rock analogs. The results support a tentative geochemical compatibility between these formulations and granitic host rock. Because the reaction produces a significant amount of thermal energy, the thermal/structural/fluid response of the plug and surrounding media was evaluated with the FEHM code. Temperatures near the plug/rock interface are estimated to peak at less than 600 deg. C and cool to near ambient temperature within a day. Rock stresses resulting from the thermal pulse are predicted to be similar to the unconfined compressive strength of granites, and generally lower than triaxial test results. Entrained fluid expansion due to heating was shown to be lower than failure stresses. Little or no failure in the surrounding media would be expected due to the plug formation process. The present efforts are focused on refining the material formulations, evaluating the geochemical and mechanical interactions between the plug and host rock, and testing the plug formation process in scaled granite and basalt masses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Damage progression and failure of SiC/SiC composite tubes under hard-contact radial expansion

The response of silicon carbide (SiC) fiber-reinforced SiC matrix (SiC/SiC) composite cladding to mechanical interaction with fissile fuel is a knowledge gap that must be overcome to design and assess SiC-based cladding systems for advanced nuclear applications. This study developed the relevant mechanical testing capability and identified the failure behavior and the critical microstructural features and processing defects. Sections of SiC composite tube were subjected to a modified expansion-due-to-compression (EDC) test in an X-ray computed tomography microscope: a polyurethane plug pressed surrogate Al 2 O 3 into the inner walls of the SiC/SiC composite tubes to achieve hard contact. A pure EDC test with just a polyurethane plug was also performed as a reference. Through the use of displacement fields, digital volume correlation revealed inhomogeneous deformation fields in the tubes, even for pure EDC, which was related to the inherent defects in the structure. Deep learning–aided segmentation and systematic data analysis revealed that the presence of inhomogeneous deformation applied by the hard contact was exaggerated by the presence of inner surface imperfections left behind from the matrix densification process. In conclusion, the findings provide insights into the applications, highlighting the necessity for improvements in inner surface roughness and the incorporation of localized contacts in pellet–cladding mechanical interaction computational models.

Composites↗

Peroxide Decomposer Module Catalyst Testing to Support Preparations for Increased Demand - 19052

The Hanford Site Effluent Treatment Facility's (ETF) mission is to receive, treat, and dispose of liquid effluents from on-site programs and projects. Its roles in the management and mitigation of tank waste volume is integral to the overall Hanford tank farms mission, as tank space is limited. ETF's role will become even more essential as the Direct-Feed Low Activity Waste process comes online at the Waste Treatment and Immobilization Plant (WTP). In order to accommodate the additional liquid effluent streams, the ETF will undergo a number of facility and equipment upgrades. Included in this is the reinstatement of the Peroxide Decomposer Module (PDM) into the ETF's main treatment train. The PDM is used to remove any residual hydrogen peroxide not fully consumed in the preceding ultraviolet/oxidation (UV/OX) treatment stage for organic destruction. Future waste stream estimates have been shown to contain organic content requiring excess hydrogen peroxide addition. Restoration of the PDM will ensure the ETF can accommodate the higher anticipated levels of organic content in these new influent streams. Due to low organic content levels in the current influents and some operability issues with the PDM, it has not been in operation since 1998. One aspect of the repair and upgrade of the PDM is the usability of manganese dioxide on alumina catalyst, Sud-Chemie T-2525, which was purchased in 2008 but has remained in storage since. The manufacturer of the catalyst states there is no known shelf life for the product and no current data to indicate the catalyst's performance after long-term storage. To determine the usability of the stored catalyst, a laboratory test was developed. The testing of this stored catalyst was based on testing methods and information collected from initial catalyst product testing performed in 2008. This test involved spiking the catalyst with 200 ppm hydrogen peroxide and then testing the resulting solution to determine the extent of peroxide destruction. Initial testing results of the Sud-Chemie T-2525 catalyst indicated reduced performance, so additional catalyst materials were selected for inclusion in the testing. These materials included Carulite{sup R} 200 catalyst, LayneOx{sup R}, natural manganese ore - pyrolusite (Pro-Ox{sup R}), and EnviCat{sup R} 2531 SPH 4-6. With the expansion of the test scope, fines generation testing was added to provide additional data for product selection, as excessive fines cause plugging in the PDM. The resulting test data are compared to the 2008 catalyst product testing data in order to evaluate performance of each product to determine whether the Sud-Chemie T-2525 is still viable and to determine the best candidate for its replacement. This testing provides essential information to the engineering and operations organizations managing the facility and equipment upgrades for the ETF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Charging Infrastructure for Plug-in Electric Vehicles at Marine Corps Base Camp Lejeune. Task 3

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for the U.S. Department of Energy’s advanced vehicle testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (Intertek) to conduct several U.S. Department of Defense-based studies to identify potential U.S. Department of Defense transportation systems that are strong candidates for introduction or expansion of plug-in electric vehicles (PEVs). Task 1 consisted of a survey of the non-tactical fleet of vehicles at Marine Corps Base Camp Lejeune to begin the review of vehicle mission assignments and types of vehicles in service. Task 2 selected vehicles for further monitoring and involved identifying daily operational characteristics of these select vehicles. Data logging of vehicle movements was initiated in order to characterize the vehicle’s mission. The Task 3 vehicle utilization report provided results of the data analysis and observations related to the replacement of current vehicles with PEVs. Finally, this report provides an assessment of charging infrastructure required to support the suggested PEV replacements. Intertek acknowledges the support of Idaho National Laboratory, Marine Corps headquarters, and Marine Corps Base Camp Lejeune Fleet management and personnel for participation in this study. Intertek is pleased to provide this report and is encouraged by enthusiasm and support from Marine Corps Base Camp Lejeune personnel.

33 ADVANCED PROPULSION SYSTEMS↗

2195 Aluminum-Copper-Lithium Friction Plug Welding Development

Technology developments and applications of friction plug welding is presented. This friction repair welding technology is being studied for implementation on the Space Transportation System's Super Light Weight External Tank. Single plug repairs will be used on a vast majority of weld defects, however, linear defects of up to several inches can be repaired by overlapping plug welds. Methods and results of tensile, bend, simulated service, surface crack tension and other tests at room and cryogenic temperatures is discussed. Attempts to implement Friction Plug Welding has led to both tool and process changes in an attempt to minimize expansive tooling and lengthy implementation times. Process control equipment and data storage methods intended for large scale production will also be addressed. Benefits include increased strength and toughness, decreased weld repair time, automated and highly reliable process, and a lower probability of having to re-repair defect locations.

Takeshita, Rike P.↗

Implementation Approach for Electric Vehicles at Marine Corps Base Camp Lejeune. Task 4

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (Intertek) to conduct several U.S. Department of Defense base studies to identify potential U.S. Department of Defense transportation systems that are strong candidates for introduction or expansion of plug-in electric vehicles (PEVs). This study is focused on the Marine Corps Base Camp Lejeune (MCBCL) located in North Carolina. Task 1 consisted of a survey of the non-tactical fleet of vehicles at MCBCL to begin the review of vehicle mission assignments and types of vehicles in service. In Task 2, daily operational characteristics of vehicles were identified to select vehicles for further monitoring and attachment of data loggers. Task 3 recorded vehicle movements in order to characterize the vehicles’ missions. The results of the data analysis and observations were provided. Individual observations of the selected vehicles provided the basis for recommendations related to PEV adoption, i.e., whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively PEVs) can fulfill the mission requirements. It also provided the basis for recommendations related to placement of PEV charging infrastructure. This report focuses on an implementation plan for the near-term adoption of PEVs into the MCBCL fleet. Intertek acknowledges the support of Idaho National Laboratory, Marine Corps headquarters, and Marine Corps Base Camp Lejeune fleet management and personnel for participation in this study. Intertek is pleased to provide this report and is encouraged by enthusiasm and support from MCBCL personnel.

33 ADVANCED PROPULSION SYSTEMS↗

Utilization Assessment of Target Electrification Vehicles at Marine Corps Base Camp Lejeune. Task 3

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (Intertek) to conduct several U.S. Department of Defense base studies to identify potential U.S. Department of Defense transportation systems that are strong candidates for introduction or expansion of plug-in electric vehicles (PEVs). Task 1 consisted of a survey of the non-tactical fleet of vehicles at MCBCL to begin the review of vehicle mission assignments and types of vehicles in service. Task 2 involved identifying daily operational characteristics of select vehicles and initiating data logging of vehicle movements in order to characterize the vehicle’s mission. Individual observations of these selected vehicles provide the basis for recommendations related to PEV adoption and whether a battery electric vehicle or plug-in hybrid electric vehicle (collectively referred to as PEVs) can fulfill the mission requirements and provide observations related to placement of PEV charging infrastructure. This report provides the results of the data analysis and observations related to replacement of current vehicles with PEVs. This fulfills part of the Task 3 requirements. Task 3 also includes an assessment of the charging infrastructure required to support this replacement, which is the subject of a separate report. Intertek acknowledges the support of Idaho National Laboratory, Marine Corps headquarters, and Marine Corps Base Camp Lejeune Fleet management and personnel for participation in this study. Intertek is pleased to provide this report and is encouraged by enthusiasm and support from MCBCL personnel.

33 ADVANCED PROPULSION SYSTEMS↗

Micro Climate Assessment of Grid-Connected Electric Drive Vehicles and Charging Infrastructure. Final Report

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for the U.S. Department of Energy’s advanced vehicle testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America to conduct several U.S. Department of Defense-based micro-climate studies to identify potential U.S. Department of Defense transportation systems that are strong candidates for introduction or expansion of plug-in electric vehicles (PEVs). The study included Joint Base Lewis McChord, located in Washington State; Naval Air Station Whidbey Island, located in Washington State; and United States Marine Corp Base Camp Lejeune, located in North Carolina. The project was divided into four tasks for each of the three bases studied. Task 1 consisted of surveying the non-tactical fleet of vehicles to begin review of vehicle mission assignments and types of vehicles in service. In Task 2, the daily operational characteristics of the vehicles were identified to select vehicles for further monitoring and attachment of data loggers. Task 3 recorded vehicle movements in order to characterize the vehicles’ missions. Results of the data analysis and observations were provided. Individual observations of these selected vehicles provided the basis for recommendations related to PEV adoption (i.e., whether a battery electric vehicle or plug-in hybrid electric vehicle [collectively referred to as PEVs] can fulfill the mission requirements). It also provided the basis for recommendations related to placement of PEV charging infrastructure. In Task 4, an implementation approach was provided for near-term adoption of PEVs into the respective fleets. Each facility was provided detailed reports on each of these tasks. This paper summarizes and provides observations on the project and completes Intertek’s required actions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing Pulse-Code Modulation On A Small Computer

System for analysis pulse-code modulation (PCM) comprises personal computer, computer program, and peripheral interface adapter on circuit board that plugs into expansion bus of computer. Functions essentially as "snapshot" PCM decommutator, which accepts and stores thousands of frames of PCM data, sifts through them repeatedly to process according to routines specified by operator. Enables faster testing and involves less equipment than older testing systems.

Massey, David E.↗

Miniature, Lightweight, One-Time-Opening Valve

The figure depicts the main parts of a prototype miniature, lightweight, onetime- opening valve. Like some other miniature one-time-opening valves reported in previous issues of NASA Tech Briefs, this valve is opened by melting a material that blocks the flow path. This valve is designed to remain closed at some temperature between room temperature and cryogenic temperature until the time of opening. The prototype valve includes a 1/8-in. (3-mm) aluminum tube, one end of which is plugged with a solder comprising about 37 weight percent of lead and 63 weight percent of tin. The tube and the solder both have a coefficient of thermal expansion of 23 micron/m-K at room temperature. Before plugging, the interior surface of the plug end of the tube is cleaned with a commercial flux paste developed specifically for preparing aluminum for bonding with lead/tin solder. The solder is then melted into the cleaned end of the tube, forming the plug. In a test, the plugged tube was pressurized to 1,000 psi (6.9 MPa) with helium and leak-tested. It was then cooled to a temperature of 77 K (about 196 C) and again leak-tested at the same pressure. Finally, at a lower pressure, the plugged end of the tube was heated to about 200 C (the melting temperature of the solder is 183 C), causing the solder plug to be ejected (see figure). It has been estimated that in a subsequent version of the valve, the plug could be melted by electrical heating, using a nichrome wire having a mass of only 10 g.

Jones, Jack↗

A Method of Strengthening Composite/Metal Joints

The term tape setback method denotes a method of designing and fabricating bonded joints between (1) box beams or other structural members made of laminated composite (matrix/ fiber) materials and (2) metal end fittings used to fasten these structural members to other structural members. The basic idea of the tape setback method is to mask the bonded interface between the metallic end fitting and composite member such that the bond does not extend out to the free edges of the composite member. The purpose served by the tape setback method is to strengthen the joints by decoupling stress concentrations from edge defects, which can cause premature failures. A related prior method that serves a similar purpose, involving the use of tapered adherends at the joints, can be too difficult and costly to be acceptable in some applications. The tape setback method offers an easier, less costly alternative. The structural members to which the method was originally applied were box beams in the form of composite tubes having flat faces with rounded corners. The end fittings were plugs made of a low-thermal- expansion nickel/iron alloy (see figure). In computational-simulation studies of tensile and compressive loading of members without tape setback, stresses were found to be concentrated at the free end edges of the composite tubes, and inspection of members that had been subjected to real tension and compression tests showed that cracks started at the free end edges. As applied to these members, the tape setback method makes them less vulnerable to initiation of failure at edge defects produced during fabrication. In real tension tests of comparable members without and with tape setback, the average mean tensile strength of the members with tape setback was found to be 1.9 times that of the members without tape setback.

Polis, Daniel L.↗