Search NASASearch

FIND YOUR NEXT DISCOVERY

Results for “experimental”

Original records, connected by a shared subject.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Experimental Demonstration of a Supersonic Spike Ejector

Spike diffusers are presented as a means to improve supersonic ejector efficiency via reduction in shock losses. Design, fabrication, and testing of an articulated prototype is described. Experimental results are compared to empirical performance curves representing the loci of optimal one- and two-stage conventional ejectors driven by dry air and discharging to atmosphere. Operated at a compression ratio of ~10 with all inputs equal, the spike ejector is shown to have achieved up to 2.19X and 1.83X the secondary mass throughput of the one- and two-stage references, respectively. This suggests the potential of spike diffusers to reduce ejector operating costs by ~50%.

wind tunnel

Optimal experimental design using eigenvalue-based criteria with Pyomo.DoE

New developments in automated optimal experimental design within the PSE+ software ecosystem. Advancements in user experience (to reduce the time taken to perform optimal experiment design) and computational capabilities (allowing more diverse experimental design) are shown with an example relevant to critical minerals and materials. Also, a small tutorial on science-based optimal experimental design and novel contributions therein are presented.

97 MATHEMATICS AND COMPUTING

Experimental Investigations of Low-Energy (4 to 40 eV) Collisions of O - ( 2 P) Ions and O( 3 P) Atoms With Surfaces

Using a newly-developed, magnetically confined source, low-energy, ground state oxygen negative ions and neutral atoms are generated. The energy range is variable, and atom and neutrals have been generated at energies varying from 2 eV to 40 eV and higher. It was found that the interaction of these low-energy species with a solid magnesium fluoride target leads to optical emissions in the (at least) visible and infrared regions of the spectrum. Researchers describe y details of the photodetachment source, and present spectra of the neutral and ion glows in the wavelength range 250 to 850 nm (for O - ) and 600 to 850 nm (for O), and discuss the variability of the emissions for incident energies between 4 and 40 eV.

A Chutjian

CatTestHub: A benchmarking database of experimental heterogeneous catalysis for evaluating advanced materials

The ability to quantitatively compare newly evolving catalytic materials and technologies is hindered by the widespread availability of catalytic data collected in a consistent manner. While certain catalytic chemistries have been widely studied across decades of scientific research, quantitative comparisons based on literature information is hindered by variability in reaction conditions, types of reported data, and reporting procedures. Here, we present CatTestHub, an open-access database dedicated to benchmarking experimental heterogeneous catalysis data. Combining systematically reported catalytic activity data for selected probe chemistries, with relevant material characterization and reactor configuration information, the database provides a collection of catalytic benchmarks for distinct classes of active site functionality. Through key choices in data access, availability, and traceability, CatTestHub seeks to balance the fundamental information needs of chemical catalysis and the FAIR data design principles. Details of the database architecture and the means through which to navigate it are presented, highlighting examples of catalytic insights readily drawn from the available benchmarking data. In its current iteration, CatTestHub spans over 250 unique experimental data points, collected over 24 solid catalysts, that facilitated the turnover of 3 distinct catalytic chemistries. Here, a roadmap is presented through which to expand the open-access platform that serves as a community wide benchmark, primarily through continuous addition of kinetic information on select catalytic systems by members of the heterogeneous catalysis community at large.

Benchmark

Experimental and analytical ion thruster research

The results of further spectroscopic studies on the plume from a 3 cm ion source operated on an argon propellant is reported on. In particular, it is shown that it should be possible to use the spectroscopic technique to measure the plasma density of the ion plume close to the grids, where it is difficult to use electrical probe measurements. How the technique, along with electrical probe measurements in the far downstream region of the plume, can be used to characterize the operation of a three-grid, 15 cm diameter thruster from NASA JPL is outlined. Pumping speed measurements on the Vacuum Research Facility have shown that this facility should be adequate for testing the JPL thruster at pressures in the low 10(exp -5) Torr range. Finally, we describe a simple analytical model which can be used to calculate the grid impingement current which results from charge-exchange collisions in the ion plume.

Wilhelmus M. Ruyten

Experimental Effervescence and Freezing Point Depression Measurements of Nitrogen in Liquid Methane-Ethane Mixtures

NASA is designing an unmanned submarine to explore the depths of the hydrocarbon-rich seas on Saturn’s moon Titan. Data from Cassini indicates that the Titan north polar environment sustains stable seas of variable concentrations of ethane, methane, and nitrogen, with a surface temperature near 93 K. The submarine must operate autonomously, study atmosphere/sea exchange, interact with the seabed, hover at the surface or any depth within the sea, and be capable of tolerating variable hydrocarbon compositions. Currently, the main thermal design concern is the effect of effervescence on submarine operation, which affects the ballast system, science instruments, and propellers. Twelve effervescence measurements on various liquid methane-ethane compositions with dissolved gaseous nitrogen are thus presented from 1.5 bar to 4.5 bar at temperatures from 92 K to 96 K to simulate the conditions of the seas. After conducting effervescence measurements, two freezing point depression measurements were conducted. The freezing liquid line was depressed more than 15 K below the triple point temperatures of pure ethane (90.4 K) and pure methane (90.7 K). Experimental effervescence measurements will be used to compare directly with effervescence modeling to determine if changes are required in the design of the thermal management system as well as the propellers.

Freezing Point Depression

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

centrifugal compressor

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

numerical simulations

Solvent-Mediated Control of Nanocellulose Dispersion: An Integrated Computational and Experimental Investigation

Fibrillated cellulose derived from forestry feedstocks represents a renewable and high-strength materials platform for circular bioeconomies. However, its practical implementation is hindered by the irreversible aggregation of nanocellulose architectures, including cellulose nanofibers (CNFs). Solvent-based dispersion offers a simple and practical route to prevent CNF aggregation. Here, in this work, we integrate classical and enhanced sampling molecular dynamics (MD) simulations with experimental suspension rheology and atomic force microscopy (AFM) to elucidate how solvent environments tune CNF–CNF interactions and dispersion stability. CNF–CNF contact free energies computed from MD simulations reveal reduced aggregation in acetone/water, γ-valerolactone (GVL)/water, and tetrahydrofuran (THF)/water and pure acetone compared with pure water, reflecting stronger CNF-solvent relative to inter-CNF interactions. Correspondingly, CNF-solvent suspensions in these solvent systems exhibit stronger inter-fibril network structures and enhanced recovery compared to water, indicating improved CNF-solvent affinity. Liquid cell AFM imaging in acetone–water mixtures and in pure acetone further confirm the presence of well-dispersed CNFs. By combining multiscale computation with targeted experiments, this study establishes a rational framework for solvent design to achieve stable nanocellulose dispersions for high-strength biobased materials and efficient bioenergy conversion.

cellulose

BEAST: Expanding Sustainable Data Infrastructure for High-Enthalpy Facilities

Reproducible, data-driven thermal protection system (TPS) research requires that experimental records from high-enthalpy testing be consistently structured, traceable, and accessible across campaigns and institutions. In practice, however, arcjet and plasma facilities data remain largely fragmented: raw diagnostics are stored in ad hoc formats, material sample histories are disconnected from test conditions, and metadata standards are absent, precluding systematic cross-campaign analysis and long-term reuse. BEAST (Backend for Experiment Analysis, Storage, and Traceability) is an open-source, web-based platform that addresses these limitations by providing a unified, queryable infrastructure for high-enthalpy ground-test data [1]. First presented at the 15th Ablation Workshop [2], BEAST has since undergone significant development. The platform ingests and structures multi-channel time-series diagnostics, facility configurations, and material property records within a common provenance model, ensuring end-to-end traceability from raw sensor acquisition to reduced experimental quantities. A versioned material library links specimen identity and processing history to the specific runs in which each sample was tested. An integrated modeling workbench enables training and evaluation of regression models directly on archived experimental data, supporting condition interpolation and the construction of empirical material response databases. Beyond its original deployment at NASA Ames Research Center, BEAST has been designed to be facility-agnostic, with ongoing efforts to extend its adoption to other facilities. Its modular architecture accommodates heterogeneous diagnostic setups and facility types, and its future open-source distribution allows institutions to build on a common data standard rather than maintaining isolated, bespoke solutions. BEAST is further integrated within a broader ecosystem of companion tools: arcjetCV [3] extracts recession rates and shock standoff distances from high-speed video using computer vision, and miniSTARscan [4] provides sub-minute, portable photogrammetric surface reconstruction of test articles before and after exposure. All tools share a common data schema, enabling seamless ingestion of surface geometry, imagery, and time-series data into a single, coherent experimental record.

Database