Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Millimeter wave near-field study

The possibility is evaluated of current technology measuring large aperture millimeter wave antennas. Included are a mathematical modeling of system errors, experimental data supporting error model, predictions of system accuracy at millimeter wavelengths, advantage of near-field measurements, and a cost estimate for a facility upgrade. The use is emphasized of software compensation and other inexpensive alternatives to develop a near optimum solution to near-field measurement problems at millimeter wavelengths.

Kefauver, Neill↗

Analysis of Performance of Stereoscopic-Vision Software

A team of JPL researchers has analyzed stereoscopic vision software and produced a document describing its performance. This software is of the type used in maneuvering exploratory robotic vehicles on Martian terrain. The software in question utilizes correlations between portions of the images recorded by two electronic cameras to compute stereoscopic disparities, which, in conjunction with camera models, are used in computing distances to terrain points to be included in constructing a three-dimensional model of the terrain. The analysis included effects of correlation- window size, a pyramidal image down-sampling scheme, vertical misalignment, focus, maximum disparity, stereo baseline, and range ripples. Contributions of sub-pixel interpolation, vertical misalignment, and foreshortening to stereo correlation error were examined theoretically and experimentally. It was found that camera-calibration inaccuracy contributes to both down-range and cross-range error but stereo correlation error affects only the down-range error. Experimental data for quantifying the stereo disparity error were obtained by use of reflective metrological targets taped to corners of bricks placed at known positions relative to the cameras. For the particular 1,024-by-768-pixel cameras of the system analyzed, the standard deviation of the down-range disparity error was found to be 0.32 pixel.

Kim, Won↗

Experimental quantum-cryptography scheme based on orthogonal states

Since, in general, nonorthogonal states cannot be cloned, any eavesdropping attempt in a quantum-communication scheme using nonorthogonal states as carriers of information introduces some errors in the transmission, leading to the possibility of detecting the spy. Usually, orthogonal states are not used in quantum-cryptography schemes since they can be faithfully cloned without altering the transmitted data. Nevertheless, L. Goldberg and L. Vaidman [Phys. Rev. Lett. 75, 1239 (1995)] proposed a protocol in which, even if the data exchange is realized using two orthogonal states, any attempt to eavesdrop is detectable by the legal users. In this scheme the orthogonal states are superpositions of two localized wave packets traveling along separate channels. Here we present an experiment realizing this scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Luminescence and radiation resistance of undoped NaI crystals

Highlights: • The performance of NaI scintillators depends on luminescence properties. • A criterion of crystals’ purity level is radiation colorability at room temperature. • The traces of the most dangerous impurities were detected. • Crucial role in efficiency of pure NaI scintillator play the crystal perfection. - Abstract: Undoped NaI single crystal is an excellent scintillator at low temperature. However, scintillation parameters of different quality crystals vary in a wide range, significantly exceeding measurement error. Experimental data demonstrate the features of luminescence, radiation induced coloration, and afterglow dependence on the quality of nominally pure crystals. It is found that defects level that allows to elucidate artefacts introduced by traces of harmful impurities corresponds to 3 × 10{sup 15} cm{sup −3} that significantly overhead accuracy of chemical and absorption analysis. It is shown that special raw material treatment before and during the single crystal growth allows to reach NaI purity level that avoids impurities influence to the basic luminescence data.

36 MATERIALS SCIENCE↗

Determination of efficiencies, loss mechanisms, and performance degradation factors in chopper controlled dc vehical motors. Section 1: Test program results and recommendations

The conventional series motor model is discussed as well as procedures for obtaining, by test, the parameters necessary for calculating performance and losses. The calculated results for operation from ripple free DC are compared with observed test results, indicating approximately 5% or less error. Experimental data indicating the influence of brush shift and chopper frequency are also presented. Both factors have a significant effect on the speed and torque relationships. The losses and loss mechanisms present in a DC series motor are examined and an attempt is made to evaluate the added losses due to harmonic currents and fluxes. Findings with respect to these losses is summarized.

Hamilton, H. B.↗

Rheology melts and magmatic suspensions. I - Design and calibration of concentric cylinder viscometer with application to rhyolitic magma

The design and calibration of concentric cylinder viscometer for rhyolitic magma applications are described together with the methods of data reduction and error analysis. Experimental data are presented on two rhyolitic magmas (melt plus a small fraction of vapor) under conditions of varying temperature (1100-1350 C) and shear rate (0.05-13.0/sec) at 100 kPa total pressure. Data obtained include a first reported measurement of a normal stress coefficient for magma.

Spera, Frank J.↗

Halving the Casimir force with conductive oxides: Experimental details

This work is an extended version of a paper published previously [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold-coated sphere and a plate coated with either gold or an indium tin oxide (I TO) layer. The experiment, which was performed in air, showed that I TO conducts sufficiently to prevent charge accumulation but is still transparent enough to halve the Casimir attraction when compared to gold. Here we report all the experimental details that, owing to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rotational relaxation of molecular H2 at moderate temperatures

A coupled rotation-vibration-dissociation model is used to compute the rotational relaxation times for molecular hydrogen as a function of final temperatures (500-5000 K) in a hypothetical scenario of sudden compression. The theoretical model is based on a master equation solver. The bound-bound and bound-free transition rates have been computed using a quasi-classical trajectory method. A review of the available experimental data on the rotational relaxation of hydrogen is presented, with a critical overview of the method of measurements and data reduction, including the sources of errors. The experimental data are compared with the computed results.

Sharma, S. P.↗

Rotational relaxation of molecular hydrogen at moderate temperatures

Using a coupled rotation-vibration-dissociation model the rotational relaxation times for molecular hydrogen as a function of final temperature (500-5000 K), in a hypothetical scenario of sudden compression, are computed. The theoretical model is based on a master equation solver. The bound-bound and bound-free transition rates have been computed using a quasiclassical trajectory method. A review of the available experimental data on the rotational relaxation of hydrogen is presented, with a critical overview of the method of measurements and data reduction, including the sources of errors. These experimental data are then compared with the computed results.

COUPLED ROTATION VIBRATION DIS↗

Uncertainty in Experimental Data Analysis [Slides]

The talk was presented virtually to the Institute of Fundamental Technological Research, Polish Academy of Sciences in Warsaw, Poland, December 21, 2020. Astronomical observations, unusual medical cases, physics experiments too costly to repeat, natural events like earthquakes, hurricanes – all of them are impossible to repeat yet produce important scientific information not achievable in other way. This data should not be treated as qualitative, anecdotal evidence only. It should be analyzed in a mathematically rigorous way to produce quantitative experimental data. Analysis method for one-of-a-kind event data differs from analysis of a repeated experiment data. For a repeated experiments the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single true experimental value. Measurement uncertainty depends on the measurement system only. Modern digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one-of-a-kind experiment are analyzed, only the measurement uncertainty can be reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification and validation of the Alternative Nonlinear Two-phase Subchannel (ANTS) code

The Alternative Nonlinear Two-phase Subchannel solver (ANTS) code was written to provide a fast-running, steady-state, pin-resolved modeling and simulation tool for analysis of common boiling water reactor (BWR) geometry and common operating conditions. ANTS has been integrated into the Virtual Environment for Reactor Application (VERA) core simulator software, where it can be used to provide a thermal/hydraulic (T/H) subchannel solution that is then used to provide neutronic feedback as well as perform the fuel depletion and temperature solution. Herein, this paper presents the rigorous analysis performed on the ANTS code, which includes both code and solution verification testing, benchmarking with the existing two-phase subchannel capability in VERA, CTF, and validation testing using popular two-phase experiments such as PWR Sub-channel and Bundle Tests (PSBT), BWR Full-size Fine-mesh Bundle Tests (BFBT), Risø, and FRIGG. This assessment was used to qualify ANTS for its intended applications before its use for core-scale, multiphysics BWR simulations. In general, it was found that agreement with experimental data was good; errors were within the range of experimental data uncertainty. Furthermore, code and solution verification confirmed that the governing equations and the most important closure terms were correctly implemented and behaving as expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Approach for Inferring Full-Scope Human Reliability Data Based on Simplified Simulator Data

This paper proposes a method for inferring full-scope human reliability data based on the Simplified Human Error Experimental Program (SHEEP) data. It mainly focuses on the human errors observed when using simulators with different complexity levels. In the proposed method, the manner in which human error probabilities (HEPs) change as a result of increasing simulator complexity and how simulator complexity levels are quantified represent key information for inferring full-scope data. In the present study, SHEEP error data pertaining to actual professional operators using Rancor Microworld (Rancor) (i.e., a more simplified simulator) and Compact Nuclear Simulator (CNS) (i.e., a less simplified simulator) were compared with the HuREX error data. An approach to quantifying simulator complexity levels was then proposed based on information theory and acquired eye-tracker data.

99 - GENERAL AND MISCELLANEOUS↗

Theoretical study of the accuracy of the pulse method, frontal analysis, and frontal analysis by characteristic points for the determination of single component adsorption isotherms

The adsorption isotherms of selected compounds are our main source of information on the mechanisms of adsorption processes. Thus, the selection of the methods used to determine adsorption isotherm data and to evaluate the errors made is critical. Three chromatographic methods were evaluated, frontal analysis (FA), frontal analysis by characteristic point (FACP), and the pulse or perturbation method (PM), and their accuracies were compared. Using the equilibrium-dispersive (ED) model of chromatography, breakthrough curves of single components were generated corresponding to three different adsorption isotherm models: the Langmuir, the bi-Langmuir, and the Moreau isotherms. For each breakthrough curve, the best conventional procedures of each method (FA, FACP, PM) were used to calculate the corresponding data point, using typical values of the parameters of each isotherm model, for four different values of the column efficiency (N = 500, 1000, 2000, and 10,000). Then, the data points were fitted to each isotherm model and the corresponding isotherm parameters were compared to those of the initial isotherm model. When isotherm data are derived with a chromatographic method, they may suffer from two types of errors: (1) the errors made in deriving the experimental data points from the chromatographic records; (2) the errors made in selecting an incorrect isotherm model and fitting to it the experimental data. Both errors decrease significantly with increasing column efficiency with FA and FACP, but not with PM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of cylindrical confinement on the determination of laminar flame speeds using outwardly propagating flames

The effect of nonspherical (i.e. cylindrical) bomb geometry on the evolution of outwardly propagating flames and the determination of laminar flame speeds using the conventional constant-pressure technique is investigated experimentally and theoretically. The cylindrical chamber boundary modifies the propagation rate through the interaction of the wall with the flow induced by thermal expansion across the flame (even with constant pressure), which leads to significant distortion of the flame surface for large flame radii. These departures from the unconfined case, especially the resulting nonzero burned gas velocities, can lead to significant errors in flame speeds calculated using the conventional assumptions, especially for large flame radii. For example, at a flame radius of 0.5 times the wall radius, the flame speed calculated neglecting confinement effects can be low by {proportional_to}15% (even with constant pressure). A methodology to estimate the effect of nonzero burned gas velocities on the measured flame speed in cylindrical chambers is presented. Modeling and experiments indicate that the effect of confinement can be neglected for flame radii less than 0.3 times the wall radius while still achieving acceptable accuracy (within 3%). The methodology is applied to correct the flame speed for nonzero burned gas speeds, in order to extend the range of flame radii useful for flame speed measurements. Under the proposed scaling, the burned gas speed can be well approximated as a function of only flame radius for a given chamber geometry - i.e. the correction function need only be determined once for an apparatus and then it can be used for any mixture. Results indicate that the flow correction can be used to extract flame speeds for flame radii up to 0.5 times the wall radius with somewhat larger, yet still acceptable uncertainties for the cases studied. Flow-corrected burning velocities are measured for hydrogen and syngas mixtures at atmospheric and elevated pressures. Flow-corrected flame speeds in the small cylindrical chamber used here agree well with previously reported flame speeds from large spherical chambers. Previous papers presenting burning velocities from cylindrical chambers report performing data analysis on flame radii less than 0.5 or 0.6 times the wall radius, where the flame speed calculated neglecting confinement effects may be low by {proportional_to}15 or 20%, respectively. For cylindrical chambers, data analysis should be restricted to flame radii less than 0.3 times the wall radius or a flow correction should be employed to account for the burned gas motions. With regard to the design of future vessels, larger vessels that minimize the flow aberrations for the same flame radius are preferred. Larger vessels maximize the relatively unaffected region of data allowing for a more straightforward approach to interpret the experimental data. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Force field for calcium sulfate minerals to predict structural, hydration, and interfacial properties

Calcium sulfates such as anhydrite, hemihydrate, and gypsum find widespread use in building materials, implants, and tissue healing. We introduce a simple and compatible atomistic force field for all calcium sulfate phases that reproduces a wide range of experimental data including lattice parameters, surface, hydration, mechanical, and thermal properties in 1% to 5% accuracy relative to experiments. The performance is several times better than prior force fields and DFT methods, which lead to errors in structures and energies up to 100%. We explain (hkl) cleavage energies, the dynamics of (hkl) water interfaces, and new insights into molecular origins of crystal-facet specific hydration and solubility. Impressive agreement of computed and experimentally measured hydration energies is shown. The models add to the Interface force field (IFF) and are compatible with multiple force fields (CHARMM, AMBER, GROMOS, CVFF, PCFF, OPLS-AA) for property predictions of sulfate-containing materials from atoms to the large nanometer scale.

36 MATERIALS SCIENCE↗

Light nuclei with semilocal momentum-space regularized chiral interactions up to third order

In this work, we present a systematic investigation of few-nucleon systems and light nuclei using the current Low Energy Nuclear Physics International Collaboration interactions comprising semilocal momentum-space regularized two- and three-nucleon forces up to third chiral order (N 2 LO). Following our earlier study utilizing the coordinate-space regularized interactions, the two low-energy constants entering the three-body force are determined from the triton binding energy and the differential cross-section minimum in elastic nucleon-deuteron scattering. Predictions are made for selected observables in elastic nucleon-deuteron scattering and in the deuteron breakup reactions, for properties of the A = 3 and A = 4 nuclei, and for spectra of p-shell nuclei up to A = 16. A comprehensive error analysis is performed including an estimation of correlated truncation uncertainties for nuclear spectra. The obtained predictions are generally found to agree with experimental data within errors. Similarly to the coordinate-space regularized chiral interactions at the same order, a systematic overbinding of heavier nuclei is observed, which sets in for A~10 and increases with A.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical accuracy of cosmic radiation neutron component recorders

A method is examined for calculating the error of experimental data from a standard neutron monitor with the multiplicity of neutron generation. It is shown that use of the Poisson distribution to estimate the real statistical error is inadequate. The method proposed is for analysis of low-amplitude periodicities in the cosmic-ray variations.

Dorman, L. I.↗

Accurate Density Calculation for Molten Slags in SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO-‘FeO’-‘Fe{sub 2}O{sub 3}’ Systems

A simple and accurate density calculation model for molten slags containing iron oxides in SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO-‘FeO’-‘Fe{sub 2}O{sub 3}’ systems is established in the present study, by extending a previous model developed for SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO systems. To quantitate the iron oxides in slags, a new method is proposed to recalculate all the iron oxides as ‘FeO’ and ‘Fe{sub 2}O{sub 3},’ which represent the iron oxides in equilibrium with metallic iron and the air atmosphere, respectively. This method is essentially different from most of the other models that dealt with ferrous (FeO) and ferric (Fe{sub 2}O{sub 3}) iron oxides. A total of 860 experimental data points for iron oxide-containing melts are critically collected for the optimization of the model parameters. The model achieves an excellent agreement with literature values with an average error of 1.96 pct and an overall absolute error of 0.092 g/cm{sup 3}. The compositional dependences from unary to multicomponent systems are discussed using the present model. The results show that the densities always increase with the increasing ‘FeO’ or ‘Fe{sub 2}O{sub 3},’ and the substitution of ‘FeO’ by ‘Fe{sub 2}O{sub 3}’ will cause a decrease in density. In the multicomponent systems, SiO{sub 2} tends to have a larger impact on the density of ‘Fe{sub 2}O{sub 3}’-containing systems compared with ‘FeO’-containing systems.

36 MATERIALS SCIENCE↗