Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental quantum-cryptography scheme based on orthogonal states

Since, in general, nonorthogonal states cannot be cloned, any eavesdropping attempt in a quantum-communication scheme using nonorthogonal states as carriers of information introduces some errors in the transmission, leading to the possibility of detecting the spy. Usually, orthogonal states are not used in quantum-cryptography schemes since they can be faithfully cloned without altering the transmitted data. Nevertheless, L. Goldberg and L. Vaidman [Phys. Rev. Lett. 75, 1239 (1995)] proposed a protocol in which, even if the data exchange is realized using two orthogonal states, any attempt to eavesdrop is detectable by the legal users. In this scheme the orthogonal states are superpositions of two localized wave packets traveling along separate channels. Here we present an experiment realizing this scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Luminescence and radiation resistance of undoped NaI crystals

Highlights: • The performance of NaI scintillators depends on luminescence properties. • A criterion of crystals’ purity level is radiation colorability at room temperature. • The traces of the most dangerous impurities were detected. • Crucial role in efficiency of pure NaI scintillator play the crystal perfection. - Abstract: Undoped NaI single crystal is an excellent scintillator at low temperature. However, scintillation parameters of different quality crystals vary in a wide range, significantly exceeding measurement error. Experimental data demonstrate the features of luminescence, radiation induced coloration, and afterglow dependence on the quality of nominally pure crystals. It is found that defects level that allows to elucidate artefacts introduced by traces of harmful impurities corresponds to 3 × 10{sup 15} cm{sup −3} that significantly overhead accuracy of chemical and absorption analysis. It is shown that special raw material treatment before and during the single crystal growth allows to reach NaI purity level that avoids impurities influence to the basic luminescence data.

36 MATERIALS SCIENCE↗

Halving the Casimir force with conductive oxides: Experimental details

This work is an extended version of a paper published previously [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold-coated sphere and a plate coated with either gold or an indium tin oxide (I TO) layer. The experiment, which was performed in air, showed that I TO conducts sufficiently to prevent charge accumulation but is still transparent enough to halve the Casimir attraction when compared to gold. Here we report all the experimental details that, owing to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Uncertainty in Experimental Data Analysis [Slides]

The talk was presented virtually to the Institute of Fundamental Technological Research, Polish Academy of Sciences in Warsaw, Poland, December 21, 2020. Astronomical observations, unusual medical cases, physics experiments too costly to repeat, natural events like earthquakes, hurricanes – all of them are impossible to repeat yet produce important scientific information not achievable in other way. This data should not be treated as qualitative, anecdotal evidence only. It should be analyzed in a mathematically rigorous way to produce quantitative experimental data. Analysis method for one-of-a-kind event data differs from analysis of a repeated experiment data. For a repeated experiments the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single true experimental value. Measurement uncertainty depends on the measurement system only. Modern digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one-of-a-kind experiment are analyzed, only the measurement uncertainty can be reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification and validation of the Alternative Nonlinear Two-phase Subchannel (ANTS) code

The Alternative Nonlinear Two-phase Subchannel solver (ANTS) code was written to provide a fast-running, steady-state, pin-resolved modeling and simulation tool for analysis of common boiling water reactor (BWR) geometry and common operating conditions. ANTS has been integrated into the Virtual Environment for Reactor Application (VERA) core simulator software, where it can be used to provide a thermal/hydraulic (T/H) subchannel solution that is then used to provide neutronic feedback as well as perform the fuel depletion and temperature solution. Herein, this paper presents the rigorous analysis performed on the ANTS code, which includes both code and solution verification testing, benchmarking with the existing two-phase subchannel capability in VERA, CTF, and validation testing using popular two-phase experiments such as PWR Sub-channel and Bundle Tests (PSBT), BWR Full-size Fine-mesh Bundle Tests (BFBT), Risø, and FRIGG. This assessment was used to qualify ANTS for its intended applications before its use for core-scale, multiphysics BWR simulations. In general, it was found that agreement with experimental data was good; errors were within the range of experimental data uncertainty. Furthermore, code and solution verification confirmed that the governing equations and the most important closure terms were correctly implemented and behaving as expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Approach for Inferring Full-Scope Human Reliability Data Based on Simplified Simulator Data

This paper proposes a method for inferring full-scope human reliability data based on the Simplified Human Error Experimental Program (SHEEP) data. It mainly focuses on the human errors observed when using simulators with different complexity levels. In the proposed method, the manner in which human error probabilities (HEPs) change as a result of increasing simulator complexity and how simulator complexity levels are quantified represent key information for inferring full-scope data. In the present study, SHEEP error data pertaining to actual professional operators using Rancor Microworld (Rancor) (i.e., a more simplified simulator) and Compact Nuclear Simulator (CNS) (i.e., a less simplified simulator) were compared with the HuREX error data. An approach to quantifying simulator complexity levels was then proposed based on information theory and acquired eye-tracker data.

99 - GENERAL AND MISCELLANEOUS↗

Theoretical study of the accuracy of the pulse method, frontal analysis, and frontal analysis by characteristic points for the determination of single component adsorption isotherms

The adsorption isotherms of selected compounds are our main source of information on the mechanisms of adsorption processes. Thus, the selection of the methods used to determine adsorption isotherm data and to evaluate the errors made is critical. Three chromatographic methods were evaluated, frontal analysis (FA), frontal analysis by characteristic point (FACP), and the pulse or perturbation method (PM), and their accuracies were compared. Using the equilibrium-dispersive (ED) model of chromatography, breakthrough curves of single components were generated corresponding to three different adsorption isotherm models: the Langmuir, the bi-Langmuir, and the Moreau isotherms. For each breakthrough curve, the best conventional procedures of each method (FA, FACP, PM) were used to calculate the corresponding data point, using typical values of the parameters of each isotherm model, for four different values of the column efficiency (N = 500, 1000, 2000, and 10,000). Then, the data points were fitted to each isotherm model and the corresponding isotherm parameters were compared to those of the initial isotherm model. When isotherm data are derived with a chromatographic method, they may suffer from two types of errors: (1) the errors made in deriving the experimental data points from the chromatographic records; (2) the errors made in selecting an incorrect isotherm model and fitting to it the experimental data. Both errors decrease significantly with increasing column efficiency with FA and FACP, but not with PM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of cylindrical confinement on the determination of laminar flame speeds using outwardly propagating flames

The effect of nonspherical (i.e. cylindrical) bomb geometry on the evolution of outwardly propagating flames and the determination of laminar flame speeds using the conventional constant-pressure technique is investigated experimentally and theoretically. The cylindrical chamber boundary modifies the propagation rate through the interaction of the wall with the flow induced by thermal expansion across the flame (even with constant pressure), which leads to significant distortion of the flame surface for large flame radii. These departures from the unconfined case, especially the resulting nonzero burned gas velocities, can lead to significant errors in flame speeds calculated using the conventional assumptions, especially for large flame radii. For example, at a flame radius of 0.5 times the wall radius, the flame speed calculated neglecting confinement effects can be low by {proportional_to}15% (even with constant pressure). A methodology to estimate the effect of nonzero burned gas velocities on the measured flame speed in cylindrical chambers is presented. Modeling and experiments indicate that the effect of confinement can be neglected for flame radii less than 0.3 times the wall radius while still achieving acceptable accuracy (within 3%). The methodology is applied to correct the flame speed for nonzero burned gas speeds, in order to extend the range of flame radii useful for flame speed measurements. Under the proposed scaling, the burned gas speed can be well approximated as a function of only flame radius for a given chamber geometry - i.e. the correction function need only be determined once for an apparatus and then it can be used for any mixture. Results indicate that the flow correction can be used to extract flame speeds for flame radii up to 0.5 times the wall radius with somewhat larger, yet still acceptable uncertainties for the cases studied. Flow-corrected burning velocities are measured for hydrogen and syngas mixtures at atmospheric and elevated pressures. Flow-corrected flame speeds in the small cylindrical chamber used here agree well with previously reported flame speeds from large spherical chambers. Previous papers presenting burning velocities from cylindrical chambers report performing data analysis on flame radii less than 0.5 or 0.6 times the wall radius, where the flame speed calculated neglecting confinement effects may be low by {proportional_to}15 or 20%, respectively. For cylindrical chambers, data analysis should be restricted to flame radii less than 0.3 times the wall radius or a flow correction should be employed to account for the burned gas motions. With regard to the design of future vessels, larger vessels that minimize the flow aberrations for the same flame radius are preferred. Larger vessels maximize the relatively unaffected region of data allowing for a more straightforward approach to interpret the experimental data. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Force field for calcium sulfate minerals to predict structural, hydration, and interfacial properties

Calcium sulfates such as anhydrite, hemihydrate, and gypsum find widespread use in building materials, implants, and tissue healing. We introduce a simple and compatible atomistic force field for all calcium sulfate phases that reproduces a wide range of experimental data including lattice parameters, surface, hydration, mechanical, and thermal properties in 1% to 5% accuracy relative to experiments. The performance is several times better than prior force fields and DFT methods, which lead to errors in structures and energies up to 100%. We explain (hkl) cleavage energies, the dynamics of (hkl) water interfaces, and new insights into molecular origins of crystal-facet specific hydration and solubility. Impressive agreement of computed and experimentally measured hydration energies is shown. The models add to the Interface force field (IFF) and are compatible with multiple force fields (CHARMM, AMBER, GROMOS, CVFF, PCFF, OPLS-AA) for property predictions of sulfate-containing materials from atoms to the large nanometer scale.

36 MATERIALS SCIENCE↗

Light nuclei with semilocal momentum-space regularized chiral interactions up to third order

In this work, we present a systematic investigation of few-nucleon systems and light nuclei using the current Low Energy Nuclear Physics International Collaboration interactions comprising semilocal momentum-space regularized two- and three-nucleon forces up to third chiral order (N 2 LO). Following our earlier study utilizing the coordinate-space regularized interactions, the two low-energy constants entering the three-body force are determined from the triton binding energy and the differential cross-section minimum in elastic nucleon-deuteron scattering. Predictions are made for selected observables in elastic nucleon-deuteron scattering and in the deuteron breakup reactions, for properties of the A = 3 and A = 4 nuclei, and for spectra of p-shell nuclei up to A = 16. A comprehensive error analysis is performed including an estimation of correlated truncation uncertainties for nuclear spectra. The obtained predictions are generally found to agree with experimental data within errors. Similarly to the coordinate-space regularized chiral interactions at the same order, a systematic overbinding of heavier nuclei is observed, which sets in for A~10 and increases with A.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accurate Density Calculation for Molten Slags in SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO-‘FeO’-‘Fe{sub 2}O{sub 3}’ Systems

A simple and accurate density calculation model for molten slags containing iron oxides in SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO-‘FeO’-‘Fe{sub 2}O{sub 3}’ systems is established in the present study, by extending a previous model developed for SiO{sub 2}-Al{sub 2}O{sub 3}-CaO-MgO systems. To quantitate the iron oxides in slags, a new method is proposed to recalculate all the iron oxides as ‘FeO’ and ‘Fe{sub 2}O{sub 3},’ which represent the iron oxides in equilibrium with metallic iron and the air atmosphere, respectively. This method is essentially different from most of the other models that dealt with ferrous (FeO) and ferric (Fe{sub 2}O{sub 3}) iron oxides. A total of 860 experimental data points for iron oxide-containing melts are critically collected for the optimization of the model parameters. The model achieves an excellent agreement with literature values with an average error of 1.96 pct and an overall absolute error of 0.092 g/cm{sup 3}. The compositional dependences from unary to multicomponent systems are discussed using the present model. The results show that the densities always increase with the increasing ‘FeO’ or ‘Fe{sub 2}O{sub 3},’ and the substitution of ‘FeO’ by ‘Fe{sub 2}O{sub 3}’ will cause a decrease in density. In the multicomponent systems, SiO{sub 2} tends to have a larger impact on the density of ‘Fe{sub 2}O{sub 3}’-containing systems compared with ‘FeO’-containing systems.

36 MATERIALS SCIENCE↗

Better models by discarding data?

Making the most of hard-won data in protein crystallography: to keep or not to keep, that is the question. In macromolecular X-ray crystallography, typical data sets have substantial multiplicity. This can be used to calculate the consistency of repeated measurements and thereby assess data quality. Recently, the properties of a correlation coefficient, CC{sub 1/2}, that can be used for this purpose were characterized and it was shown that CC{sub 1/2} has superior properties compared with ‘merging’ R values. A derived quantity, CC*, links data and model quality. Using experimental data sets, the behaviour of CC{sub 1/2} and the more conventional indicators were compared in two situations of practical importance: merging data sets from different crystals and selectively rejecting weak observations or (merged) unique reflections from a data set. In these situations controlled ‘paired-refinement’ tests show that even though discarding the weaker data leads to improvements in the merging R values, the refined models based on these data are of lower quality. These results show the folly of such data-filtering practices aimed at improving the merging R values. Interestingly, in all of these tests CC{sub 1/2} is the one data-quality indicator for which the behaviour accurately reflects which of the alternative data-handling strategies results in the best-quality refined model. Its properties in the presence of systematic error are documented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Battery Life Estimator (BLE) Data Analysis Software v. 1.2

The purpose of this software is estimate the useable life of rechargeable batteries (e.g., lithium-ion). The software employs a generalized statistical approach to model cell data in the context of accelerated aging experiments. The cell performance is modeled in two parts. The first part consists of a deterministic degradation model which models the average cell behavior. The second part relates to the statistical variation in performance of the cells (error model). Experimental data from an accelerated aging experiment will be input from an Excel worksheet. The software will then query the user for a specific model form (within the generalized model framework). Model parameters will be estimated by the software using various statistical methodologies. Average cell life will be predicted using the estimated model parameters. The uncertainty in the estimated cell life will also be computed using bootstrap simulations. This software can be used in several modes: 1) fit only, 2) fit and simulation, and 3) simulation only

Thomas, Edward↗

Measuring the oscillator strength of intercombination lines of helium-like V ions in a laser-produced-plasma

In this work, we present results of measurements of the oscillator strength of intercombination lines of He-like Vanadium ions in high energy density (HED) laser-produced-plasmas and compare them with the simulations from commonly used codes and data from the NIST database. Whilst not yet sufficiently accurate to constrain different trusted atomic-physics models for the particular system studied, our results are in agreement with the available data within experimental error bars, yet differ from cruder approximations of the oscillator strength used in certain atomic-kinetics packages, suggesting that this general method could be further extended to be used as a measurement of the oscillator strength of additional atomic transitions under the extreme conditions that are achieved in HED experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiobjective Optimal Controlled Variable Selection for a Gas Turbine–Solid Oxide Fuel Cell System Using a Multiagent Optimization Platform

Hybrid gas turbine–fuel cell systems have immense potential for high efficiency in electrical power generation with cleaner emissions compared with fossil-fueled power generation. We report a systematic controlled variable (CV) selection method is deployed for a hybrid gas turbine–fuel cell system in the HyPer (hybrid performance) facility at the U.S. Department of Energy’s National Energy Technology Laboratory (NETL) for maximizing its economic and control performance. A three-stage approach is used for the CV selection comprising a priori analysis, multiobjective optimization, and a posteriori analysis. The a priori analysis helps to screen off several candidate CVs, thus reducing the size of the combinatorial optimization problem for multiobjective CV selection. For optimal CV selection, a transfer function model of the HyPer facility is identified. By considering several candidate models, the final transfer function model is selected using Akaike’s Final Prediction Error criterion. Experimental data from the HyPer facility are used to estimate the noise in the measurement data. For solving the combinatorial multiobjective optimization problem for CV selection, a multiagent optimization platform comprising simulated annealing, genetic algorithm, and efficient ant colony optimization algorithms is used. Pareto-optimal CV sets exhibit a high trade-off between the economic and control objective. The a posteriori analysis is undertaken for several top Pareto-optimal CV sets. An optimal CV set is selected that shows the best compromise between process economics and controllability under both nominal and off-design conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamagnetic loop measurement in Korea Superconducting Tokamak Advanced Research machine

Diamagnetic loop (DL), which consists of two poloidal loops inside the vacuum vessel, is used to measure the diamagnetic flux during a plasma discharge in the Korea Superconducting Tokamak Advanced Research (KSTAR) machine. The vacuum fluxes in the DL signal can be compensated up to 0.1 mWb by using the coefficients, which are obtained from experimental investigations, in the vacuum flux measurements during vacuum shots under same operational conditions of magnetic coils for plasma experiment in the KSTAR machine. The maximum error in the diamagnetic flux measurement due to the errors of the coefficients was estimated as {approx}0.22 mWb. From the diamagnetic flux measurements for the ohmically heated circular plasmas in the KSTAR machine, the stored energy agrees well with the estimated kinetic energy within the discrepancy of 25%. When the electron cyclotron heating, the neutral beam injection, and the ion cyclotron resonance heating are added to the ohmically heated limiter plasmas, the additional heating effects can be clearly observed from the increase of the stored energy evaluated in the DL measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗