Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Numerical and Experimental Study of an Aircraft Igniter Plasma Jet Discharge

The spark discharge of an aircraft plasma jet igniter is studied using high-fidelity numerical simulations and X-ray radiography measurements. The target problem here features the thermal expansion of hot gas introduced by the electric spark within a confined igniter cavity, which eventually evolves into a pulsed jet of a high-temperature kernel. A comprehensive set of models adapted from existing strategies for internal combustion engine spark plug discharge is extended to the target problem, including the modeling of energy deposition, plasma reactions, thermodynamic properties, and heat losses. A series of validation and parameter studies are performed and presented. The kernel size is found to be sensitive to heat losses arising from radiation and hot gas remained within the discharge cavity, rather than heat conduction to the wall in the discharge cavity. Depending on the enforced shape of the post-breakdown electric arc, the spark kernel can be off-centered, tilted, and considerably asymmetric. These features have been previously not considered when studying such igniter configurations and may have a first-order impact on the ignition process. Provided a proper setup of the heat loss models and electric arc shape, the numerical results are quantitatively comparable to the experimental results in terms of the kernel size, shape, and velocity throughout different stages after the spark discharge.

Tang, Yihao↗

Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch

Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Experimental study of the edge radial electric field in different drift configurations and its role in the access to H-mode at ASDEX Upgrade

The formation of the equilibrium radial electric field (Er) has been studied experimentally at ASDEX Upgrade (AUG) in L-modes of “favorable” (ion ∇ B-drift toward primary X-point) and “unfavorable” (ion ∇ B-drift away from primary X-point) drift configurations, in view of its impact on H-mode access, which changes with drift configurations. Edge electron and ion kinetic profiles and impurity velocity and mean-field Er profiles across the separatrix are investigated, employing new and improved measurement techniques. The experimental results are compared to local neoclassical theory as well as to a simple 1D scrape-off layer (SOL) model. It is found that in L-modes of matched heating power and plasma density, the upstream SOL Er and the main ion pressure gradient in the plasma edge are the same for either drift configurations, whereas the Er well in the confined plasma is shallower in unfavorable compared to the favorable drift configuration. The contributions of toroidal and poloidal main ion flows to Er, which are inferred from local neoclassical theory and the experiment, cannot account for these observed differences. Furthermore, it is found that in the L-mode, the intrinsic toroidal edge rotation decreases with increasing collisionality and it is co-current in the banana-plateau regime for all different drift configurations at AUG. This gives rise to a possible interaction of parallel Pfirsch–Schlüter flows in the SOL with the confined plasma. Thus, the different H-mode power threshold for the two drift configurations cannot be explained in the same way at AUG as suggested by LaBombard et al. [Phys. Plasmas 12, 056111 (2005)] for Alcator C-Mod. Finally, comparisons of Er profiles in favorable and unfavorable drift configurations at the respective confinement transitions show that also the Er gradients are all different, which indirectly indicates a different type or strength of the characteristic edge turbulence in the two drift configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Experimental Study on the Transfer of Cs, Sr, Pu and Water in Concrete for the Estimation of Contamination - 20085

As part of the 'Nuclear Energy Science and Technology and Human Resources Development project- through concentrating wisdom-by MEXT' in Japan, the major results from the second year of a project on the analysis of radionuclide contamination mechanisms of concrete and the estimation of contamination distribution at the Fukushima Daiichi nuclear power station active during 2018-2020 are presented. The transfer of Cs, Sr, Pu, and water through concrete was studied experimentally. In a saturated condition, the clay did not affect the transfer and Cs penetrated much faster than Sr. In the dried condition, clay retarded Cs transfer. Carbonation of the concrete retarded the transfer of Cs and Sr. Pu was expected to be precipitated immediately in a high pH condition of concrete. Water suction depends on the temperature. Further, the detailed mechanism was analyzed by {sup 1}H-NMR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental study of high-k turbulence during an energy confinement degradation phase in EAST ohmic plasmas

In this paper, we present experimental studies of both high-k(r) ( cm(-1), and , respectively; ) and high- ( cm(-1), and , respectively; ) turbulence behavior during an ohmic energy confinement degradation phase in experimental advanced superconducting tokamak (EAST). High-k(r) turbulence from density fluctuation at and high- turbulence from density fluctuation at -0.97 were measured by tangential and poloidal CO2 laser collective scattering diagnostics, respectively. Note that k(r), , and are radial wavenumber, poloidal wavenumber, perpendicular wavenumber and ion gyroradius at electron temperature, respectively. Both high-k(r)/ turbulence power and energy confinement time are found to be temporally correlated to line-averaged electron density n(e) in the plasma current flat-top phase (I-p = 0.4 MA): when the n(e) shows continuous increase/decrease, the high-k(r)/ turbulence power increases/decreases correspondingly and the shows corresponding decrease/increase; the stable n(e) is related to stable both and high-k(r)/ turbulence power. Statistical results of high-k(r)/ turbulence power versus further imply that high-k(r)/ turbulence shows a strong correlation with plasma energy confinement degradation in high line-averaged n(e) condition, but high-k(r) and high- turbulence have relatively weak and no dependence on the transition between linear range in low-n(e) condition and energy confinement degradation in the high-n(e) condition, respectively. Moreover, profiles of electron temperature T-e and n(e) as well as their normalized gradients in a part of high- density fluctuation measurement region also have been given to qualitatively explain the enhancement of turbulence power with the increase of line-averaged n(e).

EAST tokamak↗

Theoretical and experimental studies of compression and shear deformation behavior of Osmium to 280 GPa

Abstract The compression behavior of osmium metal was investigated up to 280 GPa (volume compression V/V o = 0.725) under nonhydrostatic conditions at ambient temperature using angle dispersive axial x-ray diffraction (A-XRD) with a diamond anvil cell (DAC). In addition, shear strength of osmium was measured to 170 GPa using radial x-ray diffraction (R-XRD) technique in DAC. Both diffraction techniques in DAC employed platinum as an internal pressure standard. Density functional theory (DFT) calculations were also performed, and the computed lattice parameters and volumes under compression are in good agreement with the experiments. DFT predicts a monotonous increase in axial ratio ( c/a ) with pressure and the structural anomalies of less than 1% in ( c/a ) ratio reported below 150 GPa were not reproduced in theoretical calculations and hydrostatic measurements. The measured value of shear strength of osmium ( τ ) approaches a limiting value of 6 GPa above a pressure of 50 GPa in contrast to theoretical predictions of 24 GPa and is likely due to imperfections in polycrystalline samples. DFT calculations also enable the studies of shear and tensile deformations. The theoretical ideal shear stress is found along the (001)[1–10] shear direction with the maximal shear stress ∼24 GPa at critical strain ∼0.13.

Lin, Chia-Min↗

Experimental study of the impact of scavenging efficiency on diesel combustion in an opposed-piston two-stroke engine

The opposed-piston two-stroke (OP2S) engine is a promising alternative powertrain technology that can offer thermal and brake efficiency improvements over conventional four-stroke engines. In recent years, many of the technical barriers of the OP2S engine architecture have been overcome. However, there is still a need for fundamental studies to provide insight into the scavenging and combustion processes of the OP2S engine to help design and operate the most efficient combustion systems using this engine architecture. This work aims to provide such insights by analyzing experimental data collected on a 3-cylinder, 4.9 L OP2S engine. Specifically, a scavenging efficiency sweep, an engine speed sweep with a constant scavenging efficiency, and an engine speed with a constant pressure differential across the engine were studied in detail. It was found that in diesel combustion, as the scavenging efficiency decreased, the increase in temperature of the hot, internal residuals resulted in a significant increase in heat transfer. Despite lowering pumping losses, this resulted in an overall decrease in brake efficiency. When the bulk thermodynamic conditions of two different scavenging efficiency cases (67% and 72%) were matched at port closing, the lower scavenging efficiency case still displayed a 0.7 percentage point penalty in net thermal efficiency and an increase in engine-out indicated specific emissions of NOx of 18% due to residual stratification in the cylinder. The results presented in this work show that the optimal breathing strategy in diesel combustion on an OP2S engine architecture is one that results in a slightly under-scavenged environment at port closing. However, the results did show potential system-level efficiency benefits of decreasing scavenging efficiency, meaning that alternative fuels and combustion strategies without the constraints of diesel combustion could achieve system-level efficiency gains by running significantly under-scavenged.

Engineering↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative experimental study of heat transfer processes in accumulation energy recovery exchangers

In this study, an experimental comparison between three different energy accumulating ceramic heat exchangers for energy recovery in ventilation systems was presented. The units were selected to represent three different approaches on the energy recovery process: honeycomb structure with more accumulation mass (more energy can be stored in one unit)- Unit 1.1, honeycomb structure with lower accumulation mass- Unit 1.2, and a rectangular structure with expanded heat transfer surface- Unit 1.3. The achieved results are useful for the future application of such units in ventilation systems. It was established that all evaluated units demonstrated an acceptable effectiveness of thermal energy recovery from the exhaust air. Their average energy recovery efficiency ranged between 70 % and 80 %, aligning with expected performance benchmarks for regenerative heat exchangers employed in contemporary mechanical ventilation systems. It was also established that the factor which has the highest impact on thermal effectiveness is the heat transfer surface available in the tested heat exchangers. Units with the highest number of channels (i.e., with the highest amount of single channel walls, which can be used for heat transfer) achieve the highest thermal effectiveness. However, higher thermal effectiveness can negatively affect the ventilation potential of the units. Unit 1.3, which was characterized by the highest thermal efficiency, was also characterized by the lowest achievable flow rate. It was also found that the important technical aspect that should be taken into account when analyzing accumulation energy recovery units is also the fluctuation of the supply air temperature. The ability to ensure minimal temperature fluctuations is a significant operational advantage, as it ensures a higher level of safety at lower outside temperatures.

Energy recovery↗

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MW t SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05–653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗