Search NASA⌕ Search

SEARCH · Search NASA

Results for “exposure time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance of a 512 x 512 Gated CMOS Imager with a 250 ps Exposure Time

We describe the performance of a 512x512 gated CMOS read out integrated circuit (ROIC) with a 250 ps exposure time. A low-skew, H-tree trigger distribution system is used to locally generate individual pixel gates in each 8x8 neighborhood of the ROIC. The temporal width of the gate is voltage controlled and user selectable via a precision potentiometer. The gating implementation was first validated in optical tests of a 64x64 pixel prototype ROIC developed as a proof-of-concept during the early phases of the development program. The layout of the H-Tree addresses each quadrant of the ROIC independently and admits operation of the ROIC in two modes. If “common mode” triggering is used, the camera provides a single 512x512 image. If independent triggers are used, the camera can provide up to four 256x256 images with a frame separation set by the trigger intervals. The ROIC design includes small (sub-pixel) optical photodiode structures to allow test and characterization of the ROIC using optical sources prior to bump bonding. Reported test results were obtained using short pulse, second harmonic Ti:Sapphire laser systems operating at λ~ 400 nm at sub-ps pulse widths.

47 OTHER INSTRUMENTATION↗

Effect of laser intensity and exposure time on photothermal therapy with nanoparticles heated by a 793-nm diode laser and tissue optical clearing

Laser-induced thermotherapy is a promising method for cancer treatment, the outcome of which is affected by the exposure time. An inappropriate exposure time and laser intensity cause incomplete tumour destruction, tumour regrowth, and metastasis. Also possible is irreversible damage, i.e. death of healthy cells, and so numerical models are necessary to provide an optimised laser intensity and exposure time for different cancerous tumours. In this study, a model based on finite element method (FEM) is used for solving the bio-heat transfer equation and the Arrhenius equation describing tissue damage. The cancerous tumour is considered as a perfect cylinder with a diameter of 20 mm and a thickness of 2, 3, 4, and 5 mm, filled up by highly absorbing nanoparticles and surrounded by healthy cylindrical tissue with a diameter of 40 mm and a length of 10 mm, which ahs a low scattering coefficient due to optical clearing. The results show that 243 s is a safe and appropriate exposure time when a diode laser with a wavelength of 793 nm and intensity of 0.75 W cm{sup −2} together with gold nanorods of concentration 0.0001 % is used for the treatment of a 3-mm-thick tumour. Then, the results are developed and extensive numerical simulations are used to reveal mathematical relationships between two critical parameters, input power and optimised exposure time, for a series of different tumour thicknesses. Treatment protocols are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of oxidant concentration, exposure time, and seed particles on secondary organic aerosol chemical composition and yield

We performed a systematic intercomparison study of the chemistry and yields of secondary organic aerosol (SOA) generated from OH oxidation of a common set of gas-phase precursors in a Potential Aerosol Mass (PAM) continuous flow reactor and several environmental chambers. In the flow reactor, SOA precursors were oxidized using OH concentrations ranging from 2.0 × 10 8 to 2.2 × 10 10 molec cm -3 over exposure times of 100 s. In the environmental chambers, precursors were oxidized using OH concentrations ranging from 2 × 10 6 to 2 × 10 7 molec cm -3 over exposure times of several hours. The OH concentration in the chamber experiments is close to that found in the atmosphere, but the integrated OH exposure in the flow reactor can simulate atmospheric exposure times of multiple days compared to chamber exposure times of only a day or so. In most cases, for a specific SOA type the most-oxidized chamber SOA and the least-oxidized flow reactor SOA have similar mass spectra, oxygen-to-carbon and hydrogen-to-carbon ratios, and carbon oxidation states at integrated OH exposures between approximately 1 × 10 11 and 2 × 10 11 molec cm -3 s, or about 1–2 days of equivalent atmospheric oxidation. This observation suggests that in the range of available OH exposure overlap for the flow reactor and chambers, SOA elemental composition as measured by an aerosol mass spectrometer is similar whether the precursor is exposed to low OH concentrations over long exposure times or high OH concentrations over short exposure times. This similarity in turn suggests that both in the flow reactor and in chambers, SOA chemical composition at low OH exposure is governed primarily by gas-phase OH oxidation of the precursors rather than heterogeneous oxidation of the condensed particles. In general, SOA yields measured in the flow reactor are lower than measured in chambers for the range of equivalent OH exposures that can be measured in both the flow reactor and chambers. The influence of sulfate seed particles on isoprene SOA yield measurements was examined in the flow reactor. The studies show that seed particles increase the yield of SOA produced in flow reactors by a factor of 3 to 5 and may also account in part for higher SOA yields obtained in the chambers, where seed particles are routinely used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualisation of blood and lymphatic vessels with increasing exposure time of the detector

We describe the laser speckle contrast method for simultaneous noninvasive imaging of blood and lymphatic vessels of living organisms, based on increasing detector exposure time. In contrast to standard methods of fluorescent angiography, this technique of vascular bed imaging and lymphatic and blood vessel demarcation does not employ toxic fluorescent markers. The method is particularly promising with respect to the physiology of the cardiovascular system under in vivo conditions. (laser applications in biology and medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metal-insulator transition temperature in EuO 1−x films as a function of exposure time in air

Oxygen-deficient Europium monoxide EuO 1-x shows a metal-to-insulator transition near the Curie temperature (T C ). A systematic transport study of EuO 1-x thin films as a function of exposure time in air reveals a gradually decreased T C from 140 K to 70 K as the concentration of the oxygen vacancies decreases, which is accompanied by a drastic increase in the resistance. Here we also find an unusual enhancement of magnetic anisotropy in the transport measurements, which results from the strong spin-orbit coupling at the interface between the film and substrate and possible presence of spin-textures like skyrmions in EuO 1-x .

36 MATERIALS SCIENCE↗

Transient cycling of nitrogen, organic carbon and oxygen within the free-flowing Columbia River corridor: Linking exposure time dependent biogeochemical reactions to river stage fluctuations (Final project report)

The objective of this project was to develop next-generation techniques for representing the transformations of complex reaction networks like those impacting transient river-corridors, then apply them to develop upscaling tools. The project contributed significantly to the development of Lagrangian “mass transfer particle tracking” (MTPT) tools that are the first numerical framework that explicitly separates mixing and spreading processes; a crucial distinction for accurate representations of reaction rates across scales. The MTPT approach uses an operator splitting scheme where physical transport processes are simulated using classical random walk methods and each particle is treated as a “container” that carries with it any number of chemical species. Mixing between particles is simulated using a colocation-probability based mass transfer kernel and reactions are evaluated on each particle after mixing. The method is stable, accurate, and also allows the explicit modeling of residence time distributions of the individual containers of mass. The MTPT scheme allowed us to explore several research questions related to reactive transport in river corridors and complex reaction networks. We found that it is possible to quantify the exposure time distributions (ETDs) of reactants and that this does suggest some pathways to upscaling. However, comparable approximations can be obtained using simplified (reduced dimensionality) MTPT simulations in less time with similar uncertainty, so development of extensive ETD-based methods was not productive. The major findings are that i) the MTPT schemes are robust and highly accurate across a range of arbitrarily complex reactions, ii) the methods can be efficiently parallelized and the parallel performance characteristics of MTPT are predictable, and iii) the MTPT tools allow simultaneous tracking of residence time. The development of these research tools into efficient software packages continues. The methods are already available to the community because open-source, working examples have been included with all publications.

54 ENVIRONMENTAL SCIENCES↗

Time exposure performance of Mo-Au Gibbsian segregating alloys for extreme ultraviolet collector optics

Successful implementation of extreme ultraviolet (EUV) lithography depends on research and progress toward minimizing collector optics degradation from intense plasma erosion and debris deposition. Thus studying the surface degradation process and implementing innovative methods, which could enhance the surface chemistry causing the mirrors to suffer less damage, is crucial for this technology development. A Mo-Au Gibbsian segregation (GS) alloy is deposited on Si using a dc dual-magnetron cosputtering system and the damage is investigated as a result of time dependent exposure in an EUV source. A thin Au segregating layer is maintained through segregation during exposure, even though overall erosion in the Mo-Au sample is taking place in the bulk. The reflective material, Mo, underneath the segregating layer is protected by this sacrificial layer, which is lost due to preferential sputtering. In addition to theoretical work, experimental results are presented on the effectiveness of the GS alloys to be used as potential EUV collector optics material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinearity from stress corrosion cracking as a function of chloride exposure time using the time reversed elastic nonlinearity diagnostic

The Time Reversed Elastic Nonlinearity Diagnostic (TREND) has a long history of successful nondestructive detection of cracks in solids using nonlinear indicators. Recent research implemented TREND to find stress corrosion cracking (SCC) in the heat-affected zone adjacent to welds in stainless steel. SCC development around welds is likely to occur due to the temperature and chemical exposure of steel canisters housing spent nuclear fuel. The ideal SCC detection technique would quantify the size and extent of the SCC, rather than just locating it, as TREND has been used for in the past. The current paper explores TREND's ability to detect an assumed increase in SCC over time using 13 samples exposed to a magnesium chloride (MgCl 2 ) bath for different lengths of time. The samples are then scanned with TREND and nonlinearity is quantified for each scan point and each sample. The results suggest that TREND can be used to not only locate SCC in the heat-affected zone, but also track an increase in nonlinearity, and thereby an increase in damage, in samples exposed to the MgCl 2 solution for a longer duration.

42 ENGINEERING↗

Mechanical Property Assessment of Unirradiated Cladding After Exposure to Time at Temperature

Light water reactors in the United States are operated within inherent safety limits designed to account for anticipated operational occurrences (AOOs). Unlike more severe reactor transients, these events permit the potential reuse of reactor cladding, highlighting the nuanced role of thresholds in influencing reactor efficiency compared to design-basis or beyond-design-basis transient conditions. The threshold designated for AOO peak cladding and fuel temperatures are currently grounded around thermal hydraulic limits such as surpassing the critical heat flux (CHF), rather than in fuel-cladding material performance. This CHF criterion therefore represents a conservative approach to AOO transients during the reactor lifetime. Extending this threshold to higher temperatures than CHF can result in additional operation efficiency gains. Here, a material performance-based approach is assessed to better understand the physical material limits of short time scale exposures to elevated temperatures. This approach, termed time at temperature (t@T), references fuel cladding microstructural and mechanical response to rapid temperature transients in absence of radiation damage. The results of this work are expected to help identify margin for the United States reactor fleet, which could be utilized to increase operational efficiencies through decreased reactor outages.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Restrictions on Measurement of Roughness of Textile Fabrics by Laser Triangulation: A Phenomenological Approach

Laser triangulation method is one of the methods used for contactless measurement of roughness of textile fabrics. Method is based on measurement of distance between the sensor and the object by imaging the light scattered from the surface. However, experimental results, especially for high values of roughness, show a strong dependence to duration of exposure time to laser pulses. Use of very short exposure times and long exposures times causes appearance on the surface of the scanned textile of pixels with Active peak heights. The number of Active peaks increases with decrease of exposure time down to 0.1 ms, and increases with increase of exposure time up to 100 ms. Appearance of Active peaks leads to nonrealistic increase of roughness of the surface both for short exposure times and long exposure times reaching a minimum somewhere in the region of medium exposure times, 1 to 2 ms. The above effect suggests a careful analysis of experimental data and, also, becomes an important restriction to the method. In this paper we attempt to make a phenomenological approach to the mechanisms leading to these effects. We suppose that effect is related both to scattering properties of scanned surface and to physical parameters of CCD sensors. The first factor becomes more important in the region of long exposure times, while second factor becomes more important in the region of short exposure times.

36 MATERIALS SCIENCE↗

Early-to-mid Miocene erosion rates inferred from pre-Dead Sea rift Hazeva River fluvial chert pebbles using cosmogenic 21 Ne

In this work, we utilize a novel application of cosmogenic 21 Ne measurements in chert to compare exposure times measured in eroding surfaces in the central Jordanian Plateau with exposure times from chert pebbles transported by the Miocene Hazeva River. The Miocene Hazeva River was a large fluvial system (estimated catchment size > 100 000 km 2 ) that drained the Arabian Plateau and Sinai Peninsula into the Mediterranean Sea during the early-to-mid Miocene. It was established after the rifting of the Red Sea uplifted the Arabian Plateau during the Oligocene. Following late-Miocene-to-early-Pliocene subsidence along the Dead Sea rift, the Hazeva drainage system was abandoned and dissected, resulting in new drainage divides on either side of the rift. We find modern erosion rates derived from cosmogenic 21 Ne, 26 Al, and 10Be in exposed in situ chert nodules to be extremely slow (between 2–4 mm kyr -1 ). Comparison between modern and paleo-erosion rates, measured in chert pebbles, is not straightforward, as cosmogenic 21 Ne was acquired partly during bedrock erosion and partly during transport of these pebbles in the Hazeva River. However, 21 Ne exposure times calculated in Miocene cherts are generally shorter (ranging between $0^{+59}_{-0}$ and 242±113 kyr) compared to exposure times calculated in the currently eroding chert nodules presented here (269±49 and 378±76 kyr) and other chert surfaces currently eroding in hyperarid environments. Miocene exposure times are shorter even when considering that they account for bedrock erosion in addition to maintained transport along this large river. Shorter exposure times in Miocene cherts correspond to faster paleo-erosion rates, which we attribute to a combination of continuous surface uplift and significantly wetter climatic conditions during the early-to-mid Miocene.

58 GEOSCIENCES↗

Thermal Behavior During the Selective Laser Melting Process of Ti-6Al-4V Powder in the Point Exposure Scan Pattern

Currently, there are two main scan patterns, including the continuous exposure scan pattern and the point exposure scan pattern, during the selective laser melting (SLM) process. The point exposure scan pattern allows a three-dimensional (3-D) printer to build finer detail features as a static molten pool that is more stable than a dynamic one. However, there has been limited theoretical research on the thermal behavior characteristics during the process in the point exposure scan pattern. Therefore, in this study, the simulation of thermal behavior during SLM of Ti-6Al-4V powder in the point exposure scan pattern was performed. The temperature evolution behavior of different positions and the effects of exposure time on the temperature evolution behavior of different positions, temperature distributions, and dimensions of the molten pool were investigated. The results showed that the direct exposure position and unexposed position had significantly different temperature evolution behaviors under a given condition, and the changed exposure time had the greatest influence on the direct exposure position compared with unexposed position. Moreover, the thermal accumulation effect of a former exposure point on a later one decreased with increasing exposure time. In addition, with the increase of exposure time, the maximum temperature of the molten pool was enhanced and the surface morphology of the molten pool changed from an approximate ellipse to an approximate circle. Besides, the molten pool dimensions were found to increase with exposure time, which indicated that the exposure time played an important role in the stability of the molten pool and the metallurgical bonding in the process. Furthermore, the dimensions of the molten pool and metallurgical bonding in the cross-sectional view were obtained through experiments. Good agreement was obtained when comparing the simulated results with the experimental ones.

36 MATERIALS SCIENCE↗

Quantifying Transient States in Materials with the Dynamic Transmission Electron Microscope

The Dynamic Transmission Electron Microscope (DTEM) offers a means of capturing rapid evolution in a specimen through in-situ microscopy experiments by allowing 15 ns electron micrograph exposure times. The rapid exposure time is enabled by creating a burst of electrons at the emitter by ultraviolet pulsed laser illumination. This burst arrives a specified time after a second laser initiates the specimen reaction. The timing of the two Q-switched lasers is controlled by high-speed pulse generators with a timing error much less than the pulse duration. Both diffraction and imaging experiments can be performed, just as in a conventional TEM. The brightness of the emitter and the total current control the spatial and temporal resolutions. We have demonstrated 7 nm spatial resolution in single 15 ns pulsed images. These single-pulse imaging experiments have been used to study martensitic transformations, nucleation and crystallization of an amorphous metal, and rapid chemical reactions. Measurements have been performed on these systems that are possible by no other experimental approaches currently available.

36 MATERIALS SCIENCE↗