Search NASA⌕ Search

SEARCH · Search NASA

Results for “eye tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Vestibulo-Cervico-Ocular Responses and Tracking Eye Movements after Prolonged Exposure to Microgravity

The vestibular function and tracking eye movements were investigated in 12 Russian crew members of ISS missions on days 1(2), 4(5-6), and 8(9-10) after prolonged exposure to microgravity (126 to 195 days). The spontaneous oculomotor activity, static torsional otolith-cervico-ocular reflex, dynamic vestibulo-cervico-ocular responses, vestibular reactivity, tracking eye movements, and gaze-holding were studied using videooculography (VOG) and electrooculography (EOG) for parallel eye movement recording. On post-flight days 1-2 (R+1-2) some cosmonauts demonstrated: - an increased spontaneous oculomotor activity (floating eye movements, spontaneous nystagmus of the typical and atypical form, square wave jerks, gaze nystagmus) with the head held in the vertical position; - suppressed otolith function (absent or reduced by one half amplitude of torsional compensatory eye counter-rolling) with the head inclined statically right- or leftward by 300; - increased vestibular reactivity (lowered threshold and increased intensity of the vestibular nystagmus) during head turns around the longitudinal body axis at 0.125 Hz; - a significant change in the accuracy, velocity, and temporal characteristics of the eye tracking. The pattern, depth, dynamics, and velocity of the vestibular function and tracking eye movements recovery varied with individual participants in the investigation. However, there were also regular responses during readaptation to the normal gravity: - suppression of the otolith function was typically accompanied by an exaggerated vestibular reactivity; - the structure of visual tracking (the accuracy of fixational eye rotations, smooth tracking, and gaze-holding) was disturbed (the appearance of correcting saccades, the transition of smooth tracking to saccadic tracking) only in those cosmonauts who, in parallel to an increased reactivity of the vestibular input, also had central changes in the oculomotor system (spontaneous nystagmus, gaze nystagmus).

Kornilova, L. N.↗

Eye-Tracking Analysis from a Flight-Director-Use and Pilot-Monitoring Study

Eye tracking may be a useful tool to investigate pilot monitoring and develop and conduct training. There is increased interest from airlines to use eye-tracking technologies in flight simulators. However, much is still unknown about how to best utilize eye-tracking data in pilot training. This paper presents eye-tracking results from a pilot-monitoring training study with 19 pilots. All pilots completed 15 monitoring challenges across four operational scenarios in a B737-700 full flight simulator. In addition, the study investigated the impact of having the flight director engaged or disengaged on the pilot monitoring side in the final approach. It was hypothesized that pilots would focus less on the primary flight display with the flight director off and look more around in the cockpit. To assess this, pilots performed half of the scenarios with the flight director on and half with the flight director off. However, pilots monitoring tended to look less at the primary flight display with the flight director on as indicated by lower Proportion Dwell Times, contrary to the hypothesis. Next, eye-tracking data were analyzed from two monitoring challenges involving waypoint restrictions and two involving extending the flaps at appropriate airspeeds. Pilots that successfully completed the challenges appeared to focus more on areas of interest that contained the most relevant information to successfully complete the challenge. In addition, successful pilots seemed to adapt their monitoring strategy more to the challenge at hand as observed by a distinct shift in focus on either the primary flight display or the navigation display depending on the challenge. Our findings suggest the importance of flexible gaze allocation across specific situations and raise the question whether and to what degree prespecified patterns of eye fixation can be identified and trained.

eye tracking↗

Eye-Tracking Analysis from a Flight-Director-Use and Pilot-Monitoring Study

Eye tracking may be a useful tool to investigate pilot monitoring and develop and conduct training. There is increased interest from airlines to use eye-tracking technologies in flight simulators. However, much is still unknown about how to best utilize eye-tracking data in pilot training. This paper presents eye-tracking results from a pilot-monitoring training study with 19 pilots. All pilots completed 15 monitoring challenges across four operational scenarios in a B737-700 full flight simulator. In addition, the study investigated the impact of having the flight director engaged or disengaged on the pilot monitoring side in the final approach. It was hypothesized that pilots would focus less on the primary flight display with the flight director off and look more around in the cockpit. To assess this, pilots performed half of the scenarios with the flight director on and half with the flight director off. However, pilots monitoring tended to look less at the primary flight display with the flight director on as indicated by lower Proportion Dwell Times, contrary to the hypothesis. Next, eye-tracking data were analyzed from two monitoring challenges involving waypoint restrictions and two involving extending the flaps at appropriate airspeeds. Pilots that successfully completed the challenges appeared to focus more on areas of interest that contained the most relevant information to successfully complete the challenge. In addition, successful pilots seemed to adapt their monitoring strategy more to the challenge at hand as observed by a distinct shift in focus on either the primary flight display or the navigation display depending on the challenge. Our findings suggest the importance of flexible gaze allocation across specific situations and raise the question whether and to what degree prespecified patterns of eye fixation can be identified and trained.

eye tracking↗

Limitations on the Use of Eye-Tracking Data to Understand Operator Awareness

Safety events in commercial aviation have implicated failures of attention and awareness, and the need for improved attention and awareness has pushed trainers toward eye-tracking systems as a primary tool for evaluating monitoring performance. Further, in the last 15 years, eye-tracking technology has become easier to acquire and use in operationally realistic settings. Although we believe that eye-tracking can be a useful evaluation tool, this paper describes basic limitations on relying on eye-tracking as the sole means for evaluating attention and awareness. A set of other measures are offered that can better identify where performance breakdowns occur.

aviation↗

Limitations on the Use of Eye-Tracking Data to Understand Operator Awareness

In the last 20 years, a number of accidents and incidents in commercial aviation have pointed to poor flight crew awareness of basic flight path parameters (e.g., airspeed, bank, pitch). As a result, there is a desire to improve pilot situation awareness and how attention is allocated. Eye-tracking has been a commonly used measure of awareness; it can aid in understanding whether specific indications were fixated, and perhaps how a pilot gathered information (that is, which indications in which sequence). In this paper, we discuss limitations on what eye-tracking data can reveal about pilot awareness and understanding. First, previous studies (e.g., Sarter et al., 2007) have shown that fixation on an indication may not ensure awareness or understanding. Further, an operator may have awareness of information not fixated. Additional measures—such as self-report or control inputs—can help to better establish the extent of pilot awareness and understanding. Second, sequences of fixations (scan patterns) have also become a performance measure. While a small number of recognized scan patterns have been validated for a small set of parameters on the Primary Flight Display (PFD), scan patterns have not been identified to support the broader context of flight path management or flight operations. More important is to understand the full set of drivers underlying the larger pattern of eye fixations; this approach moves away from the idea of well-established scan patterns as a marker of skilled performance and gives a larger role to pilot cognition. Pilots have various reasons to direct attention to specific elements on the interface, such as: - feedback tied to control inputs - a check on compliance with flight path targets - a reaction to an alert or a call out - attempt to understand an unexpected indication - assess progress toward a flight path target The importance of cognition is further implicated in the finding that pilot interviews show that fixating typically is accompanied by expectation; generally, pilots have a strong expectation of what value or indication they will see, which allows more efficient integration of information and an ability to identify indications that suggest an alternative account of the current system state. We will describe a range of eye-tracking measures and how they should and should not be used.

aviation↗

Eye Tracking Metrics for Workload Estimation in Flight Deck Operation

Flight decks of the future are being enhanced through improved avionics that adapt to both aircraft and operator state. Eye tracking allows for non-invasive analysis of pilot eye movements, from which a set of metrics can be derived to effectively and reliably characterize workload. This research identifies eye tracking metrics that correlate to aircraft automation conditions, and identifies the correlation of pilot workload to the same automation conditions. Saccade length was used as an indirect index of pilot workload: Pilots in the fully automated condition were observed to have on average, larger saccadic movements in contrast to the guidance and manual flight conditions. The data set itself also provides a general model of human eye movement behavior and so ostensibly visual attention distribution in the cockpit for approach to land tasks with various levels of automation, by means of the same metrics used for workload algorithm development.

Ellis, Kyle↗

High-Speed Noninvasive Eye-Tracking System

The figure schematically depicts a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. Like prior commercial noninvasive eye-tracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Relative to the prior commercial systems, the present system operates at much higher speed and thereby offers enhanced capability for applications that involve human-computer interactions, including typing and computer command and control by handicapped individuals,and eye-based diagnosis of physiological disorders that affect gaze responses.

Talukder, Ashit↗

Algorithms for High-Speed Noninvasive Eye-Tracking System

Two image-data-processing algorithms are essential to the successful operation of a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. The system was described in High-Speed Noninvasive Eye-Tracking System (NPO-30700) NASA Tech Briefs, Vol. 31, No. 8 (August 2007), page 51. To recapitulate from the cited article: Like prior commercial noninvasive eyetracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Most of the prior commercial noninvasive eyetracking systems rely on standard video cameras, which operate at frame rates of about 30 Hz. Such systems are limited to slow, full-frame operation. The video camera in the present system includes a charge-coupled-device (CCD) image detector plus electronic circuitry capable of implementing an advanced control scheme that effects readout from a small region of interest (ROI), or subwindow, of the full image. Inasmuch as the image features of interest (the cornea and pupil) typically occupy a small part of the camera frame, this ROI capability can be exploited to determine the direction of gaze at a high frame rate by reading out from the ROI that contains the cornea and pupil (but not from the rest of the image) repeatedly. One of the present algorithms exploits the ROI capability. The algorithm takes horizontal row slices and takes advantage of the symmetry of the pupil and cornea circles and of the gray-scale contrasts of the pupil and cornea with respect to other parts of the eye. The algorithm determines which horizontal image slices contain the pupil and cornea, and, on each valid slice, the end coordinates of the pupil and cornea. Information from multiple slices is then combined to robustly locate the centroids of the pupil and cornea images. The other of the two present algorithms is a modified version of an older algorithm for estimating the direction of gaze from the centroids of the pupil and cornea. The modification lies in the use of the coordinates of the centroids, rather than differences between the coordinates of the centroids, in a gaze-mapping equation. The equation locates a gaze point, defined as the intersection of the gaze axis with a surface of interest, which is typically a computer display screen (see figure). The expected advantage of the modification is to make the gaze computation less dependent on some simplifying assumptions that are sometimes not accurate

Talukder, Ashit↗

High-Procession Eye Tracking Using Fundus Images

Fundus images provide high optical gain for eye movement tracking, i.e. large image displacements occur as a result of small eye rotations. Subpixel registration techniques can provide resolution better than 1 arc minute using images acquired with a CCD camera. Ocular torsion may also be estimated, with a precision of approximately 0.1 degree. This talk will discuss the software algorithms used to attain this performance.

Mulligan, Jeffrey B.↗

Analysis of Eye-Tracking Data with Regards to the Complexity of Flight Deck Information Automation and Management - Inattentional Blindness, System State Awareness, and EFB Usage

In the constant drive to further the safety and efficiency of air travel, the complexity of avionics-related systems, and the procedures for interacting with these systems, appear to be on an ever-increasing trend. While this growing complexity often yields productive results with respect to system capabilities and flight efficiency, it can place a larger burden on pilots to manage increasing amounts of information and to understand intricate system designs. Evidence supporting this observation is becoming widespread, yet has been largely anecdotal or the result of subjective analysis. One way to gain more insight into this issue is through experimentation using more objective measures or indicators. This study utilizes and analyzes eye-tracking data obtained during a high-fidelity flight simulation study wherein many of the complexities of current flight decks, as well as those planned for the next generation air transportation system (NextGen), were emulated. The following paper presents the findings of this study with a focus on electronic flight bag (EFB) usage, system state awareness (SSA) and events involving suspected inattentional blindness (IB).

Dill, Evan T.↗

Analysis of Eye-Tracking Data During Conditions Conducive to Loss of Airplane State Awareness

In the constant drive to further the safety and efficiency of air travel, the complexity of avionics-related systems and of the procedures for interacting with them appear to be on an ever-increasing trend. While this growing complexity often yields productive results with respect to system capabilities and flight efficiency, it typically places a larger burden on pilots to manage increasing amounts of information and to understand intricate system designs. This can be problematic as too much information and/or ineffective provisions of information can potentially overwhelm and/or confuse pilots, and as a result, increase the likelihood of loss of airplane state awareness (ASA). One way to gain more insight into this issue is through experimentation using more objective measures. This study summarizes an analysis of eye-tracking data obtained during a high-fidelity flight simulation study that included most of the complexities of current flight decks, as well as several planned for the next generation air transportation system. Multiple analyses were performed to understand how the 22 participating airline pilots were observing ASA-related information provided during different stages of flights and in response to specific events within these stages. Also, study findings are compared to data presented in similar previous studies to assess trends or common themes regarding how airline crews apply visual attention in complex flight deck and operational environments.

Dill, Evan T.↗

Flight Deck Interval Management Avionics: Eye-Tracking Analysis

Interval Management (IM) is one NexGen method for achieving airspace efficiencies. In order to initiate IM procedures, Air Traffic Control provides an IM clearance to the IM aircraft's pilots that indicates an intended spacing from another aircraft (the target to follow - or TTF) and the point at which this should be achieved. Pilots enter the clearance in the flight deck IM (FIM) system; and once the TTF's Automatic Dependent Surveillance-Broadcast signal is available, the FIM algorithm generates target speeds to meet that IM goal. This study examined four Avionics Conditions (defined by the instrumentation and location presenting FIM information) and three Notification Methods (defined by the visual and aural alerts that notified pilots to IM-related events). Current commercial pilots flew descents into Dallas/Fort-Worth in a high-fidelity commercial flight deck simulation environment with realistic traffic and communications. All 12 crews experienced each Avionics Condition, where order was counterbalanced over crews. Each crew used only one of the three Notification Methods. This paper presents results from eye tracking data collected from both pilots, including: normalized number of samples falling within FIM displays, normalized heads-up time, noticing time, dwell time on first FIM display look after a new speed, a workload-related metric, and a measure comparing the scan paths of pilot flying and pilot monitoring; and discusses these in the context of other objective (vertical and speed profile deviations, response time to dial in commanded speeds, out-of-speed-conformance and reminder indications) and subjective measures (workload, situation awareness, usability, and operational acceptability).

Latorella, Kara↗

Head-eye tracking in two-dimensional pursuit tasks

The neurological control systems for the eye and head are studied by investigating dynamic eye and head rotations in two degrees of freedom using bandlimited, white noise stimuli, nominally wide field of view stimulus presentations of + or - 10 deg and power spectral analysis of the data to produce input/output transfer and coherence functions. Determined were frequency response characteristics of these systems, the linearity of the transfer functions in both coupled and decoupled vertical and horizontal stimulus/response reference axes and the amount of cross axis coupling present in system responses. A comparative study was also conducted to assess the differences in response characteristics between single axis and dual axis visual stimulation for the same subject.

Shirachi, D. K.↗

Image processing for improved eye-tracking accuracy

Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

NASA Discipline Space Human Factors↗

Two dimensional eye tracking: Sampling rate of forcing function

A study was conducted to determine the minimum update rate of a forcing function display required for the operator to approximate the tracking performance obtained on a continuous display. In this study, frequency analysis was used to determine whether there was an associated change in the transfer function characteristics of the operator. It was expected that as the forcing function display update rate was reduced, from 120 to 15 samples per second, the operator's response to the high frequency components of the forcing function would show a decrease in gain, an increase in phase lag, and a decrease in coherence.

Hornseth, J. P.↗

An Investigation of Horizontal Combined Eye-Head Tracking in Patients with Abnormal Vestibular and Smooth Pursuit Eye Movements

We investigated the interaction of smooth ocular pursuit (SP) and the vestibulo-ocular reflex (VOR) during horizontal, combined eye-head tracking (CEHT) in patients with abnormalities of either the VOR or SP movements. Our strategy was to apply transient stimuli that capitalized on the different latencies to onset of SP and the VOR. During CEHT of a target moving at 15 deg/sec, normal subjects and patients with VOR deficits all tracked the target with a gain close to 1.O. When the heads of normal subjects were suddenly and unexpectedly braked to a halt during CEHT, the eye promptly began to move in the orbit to track the target, but eye-in-orbit velocity transiently fell to about 60-70% of target velocity. In patients with deficient labyrinthine function, following the onset of the head brake, eye movements to track the target were absent, and SP movements were not generated until about 100 msec later. In patients with deficient SP, CEHT was superior to SP tracking with the head stationary; after the onset of the head brake, tracking eye movements were initiated promptly, but eye velocity was less than 50% of target velocity and increased only slightly thereafter. These results indicate that at least two mechanisms operate to overcome the VOR and allow gaze to track the target during CEHT: (1) the SP system provides a signal to cancel a normally-operating VOR (this cancellation signal is not needed by labyrinthine-deficient patients who have no VOR to cancel), and (2) a reduction of the gain of the VOR is achieved, an ability that is preserved even in patients with cerebral lesions that impair SP.

Huebner, William P.↗