Search NASASearch

SEARCH · Search NASA

Results for “fast frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION

Quantified Fast Frequency Response of Inverter-Based Resources for Bulk-Power System Study

Quantifying fast frequency response (FFR) of inverter-based resources (IBRs) is crucial for robust frequency regulation, managing resources, and improving system reliability in the power grids with high penetration levels of IBRs. This paper proposes a concept of frequency response scheme that its response is quantifiable and applicable to the generic IBR models. To achieve this, a stepwise-energy function is derived as a control module by considering operational constraints of IBRs. Then the module is implemented along with generic IBR models in electromagnetic transient (EMT) and electromechanical-based software. To quantify the FFR, the implemented module calculates available incremental active power for a specific time duration. This energy profile is being updated depending on IBR’s operating conditions and is provided into a power grid upon detecting a frequency event. Thus, due to this characteristic, this scheme can quantify the FFR and enable applicable IBRs to provide their available headroom within frequency arrest period. Thereby, this scheme can help estimate IBRs’ frequency response and is more effective in improving the initial frequency response than frequency-dependent control schemes: rate-of-change-of-frequency based and droop-based control schemes. The performance of the proposed scheme was tested under different IBR penetration levels using PSLF and PSCAD simulators.

Kim, Jinho

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION

Deep Reinforcement Learning Based Control of Wind Turbines for Fast Frequency Response

In order to fulfill vital auxiliary grid services, such as load regulation, spin and non-spin reserve provision, and frequency support during emergencies, there is often a requirement for certain wind farms to operate in de-loaded modes. Leveraging the swift response capabilities of wind farms, this study demonstrates that reserving power in de-loaded modes can significantly enhance power grid stability and reliability during system contingencies. Controlling wind farms optimally for frequency support is intricate due to the nonlinearity of models and controllers and the complexity of wind farm interactions with power systems. Here, to address this challenge, this paper introduces a novel approach that integrates wind turbines into reinforcement learning-based solutions for frequency response. This innovative methodology utilizes the state-of-the-art reinforcement learning algorithm known as the surrogate-gradient-based evolutionary strategy. The proposed learning-based algorithm provides continuous control of wind farm output to rapidly stabilize system frequency and prevent unnecessary trips of under-frequency load shedding relays. To facilitate efficient training, parallel computing techniques are employed. The proposed methodology is evaluated on a modified IEEE-39 bus system, and simulation results reveal its efficacy in reliably supporting power system frequency and preventing the need for unnecessary load shedding.

Gao, Wei [Argonne National Laboratory (ANL), Argon

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE

Digital Filter Design for Point-on-Wave Sensors: Highlighting Frequency Response Limitations and Enhancing Grid Simulation Accuracy

Data is proving to be the backbone of today's and, more importantly, tomorrow's grid. As the system changes and introduces fast-acting devices like power electronics, overall observability tends to decrease from the utility point-of-view. This can be mitigated by adding more high-fidelity sensors onto the grid, although this incurs a cost. These sensors are never ideal, and each have unique frequency responses that may influence the data produced. This may, in turn, impact the protection and control of the power grid. This paper presents a methodology of representing these point-on-wave sensors digitally by estimating digital-filter representations of them, thereby introducing means of improving the sensor models used in electromagnetic-transient (EMT) simulations. This may help with identifying potential high-frequency, sensor-induced distortions, and system resonance compensation. Three commercial-grade medium-voltage point-on-wave sensors are utilized in a lab environment to obtain experimental frequency responses with a frequency sweep, and it is shown that both Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filter representations may approximate these responses with varying degrees of accuracy, though each has their own strengths and weaknesses. It is found that, in general, FIR estimation better approximates these sensors than IIR estimation does.

Wilson, Aaron [ORNL] (ORCID:0000000327331697)

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION

Mitigating the Effect of Wind Gusts on Local Run-of-River Hydropower Plants Using Cooperative Control

This paper focuses on the challenges and solutions associated with the integration of wind farms in a hydro- dominated power system. Due to sudden increases in wind power, the system frequency can increase, causing excessive reduction in the run-of-river (ROR) system’s power. Considering their small pondage, this can result in damage to the physical structure due to water level violations which are also penalized by stakeholders. To prevent excessive ROR power deviations, ROR governor wear and tear, and to prevent tie-line deviations, a centralized, distributed, and hybrid scheme for coordinating the response from a cluster of ROR plants is examined. Both centralized and distributed control as well as their hybrids can reduce frequency peaks. However, the inclusion of decentralized cooperative controls leads to reduced governor actions from fast- acting plants while enhancing net response from the hydro unit cluster.

13 HYDRO ENERGY

Double-null power-sharing dynamics in MAST-U

Maintaining an effective double-null (DN) configuration is expected to be challenging in reactor-scale tokamak devices. As divertor power-sharing is closely linked to the magnetic topology, even minor variations can lead to fast power-sharing fluctuations which exacerbate the already daunting exhaust challenge. While the static aspects of DN power-sharing have been extensively studied across various devices, this paper presents the first detailed investigation of its dynamic behaviour. We employ dedicated H-mode experiments in MAST-U, in Super-X divertor configuration, featuring perturbation frequencies up to 200 Hz. Our results clearly show no significant dynamic damping of the power-sharing within this frequency range: the divertor responds equally to both fast and slow perturbations. Moreover, the dynamic response also aligns with quasi-static results from slow ramps, implying that static power-sharing models remain valid even for fast fluctuations. Occasionally, some deviations from the otherwise mainly linear behaviour are observed, alongside notable scatter and asymmetries between upwards and downwards trajectories. These observations are likely linked to changes in core conditions, though the underlying mechanisms remain unclear and require further study.

divertor

Expanded Accident Scenarios and Frequency Characteristics for a Fast Spectrum Molten Salt Reactor in an Integrated Energy System

Integration of advanced nuclear reactors to industrial processes in an integrated energy system (IES) has many potential advantages. The coupling of nuclear power to varied industrial processes introduces additional accident scenarios unique to the specific systems included in the IES. Similarly, noise in one system of the IES could potentially create negative effects in the other systems. Because of the limited amount of comparable nuclear IES operating experience, there is added value in scoping the inherent behavior of these systems in response to these transients. Here, this paper investigates the safety-related behavior of an open-source IES dynamic model of a fast spectrum molten salt reactor (MSR) powering a regenerative Rankine cycle for electricity production and a hybrid sulfur (HyS) cycle for hydrogen production. The simulations include a loss of cooling water to the Rankine cycle, a loss of sulfur in the HyS cycle, and the frequency characteristics of the entire IES across six orders of magnitude of frequency. The results show safe behavior in response to the two accident scenarios, wherein a disruption in heat transfer leads to increased salt temperatures and a decrease in reactor power. The frequency analysis shows that at higher frequencies, temperature changes propagating through an IES are increasingly damped to the point of negligibility.

Dunkle, Nicholas [Univ. of Tennessee, Knoxville, T

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING