Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental Investigation of Nanosecond and Subnanosecond Pulsed DBD in Atmospheric Air: Fast Imaging and Spectroscopy

Dielectric barrier discharge (DBD), as an easy and simple way of generation of non-thermal plasma, has found a number of applications in variuos fields. However, development of a homogeneous, or uniform, DBD that would operate at atmospheric pressure conditions in atmospheric air, would open a number of new applications in various fields from thin film coatings to plasma medicine. Unfortunately, at atmospheric pressure, a uniform DBD can be easily transformed into a filamentary dielectric DBD; therefore some serious issues arise, such as gas heating due to strong discharges in the random microdischarge channel and non-uniform energy distribution, which adversely affect applications. These issues traditionally are solved by the use of an appropriate working gas composition, an alternating current driving frequency, lowering of gas pressure, etc. The transitions between discharge modes in the same experimental conditions have been thoroughly investigated in nitrogen, rare gases and their mixtures with air and other gases. In many cases (for example, in plasma medicine), these methods, especially those related to gas composition and pressure, may not be applied in a convenient manner. Recent advances in pulsed power technology permitted application of much faster voltage rise times (including the subnanosecond range) and short (few nanoseconds) pulses, and revealed that uniform DBD can, in fact, be generated in atmospheric air. Such discharges are in the great interest for many applications, however to date there still little understanding of the mechanisms of their operation and characteristics. Currently, there is no adequate model of the uniform dielectric barrier discharge development in atmospheric air. Although extensive studies have been performed on understanding of the nature of the pulsed DBD uniformity, until now there is still little understanding of the mechanism of the DBD transition from the filamentary mode to uniform mode. One of the reasons for this is that development of streamers, and later – filaments, occurs on the sub-nanosecond and nanosecond time scales, and therefore requires imaging and other diagnostic techniques with corresponding speed of registration. Recently developed technologies allow such studies. Here we demonstrate that DBD uniformity strongly depends on applied electric field in the discharge gap. More specifically, the discharge uniformity may be achieved in the case when two conditions are satisfied: (1) stong overvoltage in the discharge gap (provided by fast rise times), when anode-directed streamers are formed, and (2) short pulse duration that prevents discharge overheating due to rising conductivity (current) which leads to formation of filaments. We show that by controlling the applied (global) electric field in ns-pulsed DBD, it is possible to control the uniformity of the discharge. In addition, this offers better control of the discharge chemistry due to local changes of electric fields and therefore electron energy distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement in the spatial resolution for imaging with fast neutrons

In this paper, we report on the realization of an improved concept for the detection of fast neutrons using a specific setup of scintillators with the aim to overcome limitations in spatial resolution. While fast neutron imaging (FNI) is a technique to investigate very thick material layers in transmission mode, currently there is a limit in the spatial resolution at ~1 mm, which hinders the performance for the detection of features like cracks, material damage or pores in large objects ($\gg$1 cm 3 ). The improved concept presented here is based on the separation of the converter material from the scintillation layer in a suitable way, which was successfully tested and referenced to the standard devices at the NECTAR facility (FRM-2, MLZ, Garching) under realistic beamline conditions. The results imply a break-through in enabling detection of structures on the order of 0.2 to 0.5 mm (a more precise estimation is not possible due to other resolution determing factors in a realistic setup). Potential additional improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Imaging and Tomography at NIF [Slides]

The presentation at the first Prompt Radiation Detection and Imaging Workshop covered fast neutron and tomography work at the National Ignition Facility (NIF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hybrid machine-learning approach for analysis of methane hydrate formation dynamics in porous media with synchrotron CT imaging

Fast multi-phase processes in methane hydrate bearing samples pose a challenge for quantitative micro-computed tomography study and experiment steering due to complex tomographic data analysis involving time-consuming segmentation procedures. This is because of the sample's multi-scale structure, which changes over time, low contrast between solid and fluid materials, and the large amount of data acquired during dynamic processes. Here, a hybrid approach is proposed for the automatic segmentation of tomographic data from time-resolved imaging of methane gas-hydrate formation in sandy granular media, which includes a deep-learning 3D U-Net model. To prepare a training dataset for the 3D U-Net, a technique to automate data labeling based on sample-specific information about the mineral matrix immobility and occasional fluid movement in pores is proposed. Automatic segmentation allowed for studying properties of the hydrate growth in pores, as well as dynamic processes such as incremental flow and redistribution of pore brine. Results of the quantitative analysis showed that for typical gas-hydrate stability parameters (100 bar methane pressure, 7°C temperature) the rate of formation is slow (less than 1% per hour), after which the surface area of contact between brine and gas increases, resulting in faster formation (2.5% per hour). Hydrate growth reaches the saturation point after 11 h of the experiment. Finally, the efficacy of the proposed segmentation scheme in on-the-fly automatic data analysis and experiment steering with zooming to regions of interest is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spatiotemporal characterization of cerium monoxide in laser ablation plasmas using spectrally-resolved fast-gated imaging

The impact of oxidation chemistry on the emission characteristics and spatial structure of laser-produced Ce metal plasmas was investigated using laser-induced breakdown spectroscopy (LIBS) and time-resolved fast-gated imaging employing narrowband optical filters. Images of the plasma emission show that CeO coexists with atomic species in the periphery and vortex ring of the plasma plume. Image processing was also applied to combine independent monochromatic images of the plasma emission into a single merged image, culminating in a timelapse on the spatiotemporal evolution of atomic and molecular species within the plasma plume. The formation of CeO species was observed to proceed faster for plasmas generated in atmospheres containing larger concentrations of oxygen based on ratios of CeO-to-atomic emission intensities. Furthermore, these same ratios were shown to plateau and decrease at later times (≥25 μs), potentially indicating the depletion of CeO number densities in the plasma as the monoxide undergoes reactions to form higher polyatomic oxides. Altogether, these results provide fundamental insights into the chemical dynamics and intermixing between plasma-gas species in laser ablation cerium plasmas, advancing our understanding on optical signatures of nuclear-relevant materials to enable in-field measurement capabilities.

47 OTHER INSTRUMENTATION↗

Fast widefield imaging of neuronal structure and function with optical sectioning in vivo

Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.

42 ENGINEERING↗

Plasma-assisted deflagration to detonation transition in a microchannel with fast-frame imaging and hybrid fs/ps coherent anti-Stokes Raman scattering measurements

Our study examines kinetic enhancement by nanosecond dielectric barrier discharge (ns-DBD) plasma on fuellean dimethyl ether (DME), oxygen (O 2 ), and argon (Ar) premixtures during deflagration to detonation transition (DDT) experiments in a microchannel. Non-equilibrium plasma produces active species and radicals and creates fast and slow heating of a mixture to promote ignition due to electronic and vibrational excitation. Experiments have been conducted to examine the influence of the plasma discharge on the premixture and on the resultant deflagration to detonation transition (DDT) onset time and distance through the use of high speed imaging and one-dimensional, two-beam, femtosecond/picosecond, coherent anti-Stokes Raman scattering (CARS). A highspeed camera is used to trace the time histories of flame front position and velocity and to identify the dynamics and onset of DDT. The results show that plasma discharge can nonlinearly affect the onset time and distance of DDT. It is shown that a small number of plasma discharge pulses prior to ignition result in reduced DDT onset time and distance by 60% and 40%, respectively, when compared to the results without pre-excitation by ns discharges. The results also show that an increase of plasma discharge pulses results in an extended DDT onset time and distance of 224% and 94%, respectively. Time history of the deflagration wave speed of DME and the analysis of ignition timescale under the choking condition of the deflagration front suggest low temperature ignition may play a role for DME near the isobaric choking condition of the burned gas and the DDT. Plasmainduced conversion of the reactive mixture was assessed via the O 2 to CO 2 ratio as measured through fs/ps CARS during the DBD discharges. The present experiments demonstrate the ability of non-equilibrium plasma to alter the chemistry of DME/O 2 /Ar premixtures in order to control DDT for applications in advanced propulsion engines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗