Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

System and plastic scintillator for discrimination of thermal neutron, fast neutron, and gamma radiation

A scintillator material according to one embodiment includes a polymer matrix; a primary dye in the polymer matrix, the primary dye being a fluorescent dye, the primary dye being present in an amount of 3 wt % or more; and at least one component in the polymer matrix, the component being selected from a group consisting of B, Li, Gd, a B-containing compound, a Li-containing compound and a Gd-containing compound, wherein the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays. A system according to one embodiment includes a scintillator material as disclosed herein and a photodetector for detecting the response of the material to fast neutron, thermal neutron and gamma ray irradiation.

36 MATERIALS SCIENCE↗

Lithium-containing scintillators for thermal neutron, fast neutron, and gamma detection

In one embodiment, a scintillator includes a scintillator material; a primary fluor, and a Li-containing compound, where the Li-containing compound is soluble in the primary fluor, and where the scintillator exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons and gamma rays.

36 MATERIALS SCIENCE↗

Development of a ZnS (Ag)-Silicon Photomultiplier Fast Neutron Detector for the Fast Neutron Hodoscope at TREAT

The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory is being restored to support the mission of advanced reactor and fuel development in the United States. A key part of this restoration is the fast neutron hodoscope which images the fuel under test during extreme transient conditions. Traditionally, this has been comprised of ZnS (Ag)-based proton recoil scintillators (PRS) coupled to photomultiplier tubes (PMTs), but silicon photomultipliers (SiPMs) have emerged as a promising candidate to replace PMTs in this application. This work develops, tests, and evaluates a SiPM-based PRS detector for incorporation into the updated Fuel Motion Monitoring System (FMMS) at TREAT. The primary characteristic to be optimized is the gamma rejection efficiency of the detector which will be done using pulse shape discrimination (PSD). To do so multiple types of SiPMs will be tested with multiple PRS buttons and compared using standard PSD figures of merit. Consideration to count rates will also be given and consequently to the detector’s electrical time constants. Once the ideal SiPM has been selected for the PRS detectors, its gamma rejection efficiency will be characterized, and benchmarked to the traditional PMT-PRS detectors. PSD performance for this detector will also be characterized as a function of temperature.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Experimental setup for the determination of the correction factors of the neutron doseratemeters in fast neutron fields

The use of the U-120 Cyclotron of the IFIN-HH allowed to perform a testing bench with fast neutrons in order to determine the correction factors of the doseratemeters dedicated to neutron measurement. This paper deals with researchers performed in order to develop the irradiation facility testing the fast neutrons flux generated at the Cyclotron. This facility is presented, together with the results obtain in determining the correction factor for a doseratemeter dedicated to the neutron dose equivalent rate measurement.

07 ISOTOPE AND RADIATION SOURCES↗

ANALYTICAL NEUTRONIC STUDIES CORRELATING FAST NEUTRON FLUENCE TO MATERIAL DAMAGE IN CARBON, SILICON, AND SILICON CARBIDE

This study evaluates how fast neutron fluence >0.1 MeV correlates to material damage (i.e., the total fluence spectrum folded with the respective material’s displacements-per- atom [dpa] damage response function) for the specific material fluence spectra encountered in Next Generation Nuclear Plant (NGNP) service and the irradiation tests conducted in material test reactors (MTRs) for the fuel materials addressed in the white paper. It also reports how the evaluated correlations of >0.1 MeV fluence to material damage vary between the different spectral conditions encountered in material service versus testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. Furthermore, the expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. In the three areas we analyzed, San Francisco, Downtown Oakland, and Berkeley, all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications

Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

Preliminary investigations of Monte Carlo Simulations of neutron energy and LET spectra for fast neutron therapy facilities

No fast neutron therapy facility has been built with optimized beam quality based on a thorough understanding of the neutron spectrum and its resulting biological effectiveness. A study has been initiated to provide the information necessary for such an optimization. Monte Carlo studies will be used to simulate neutron energy spectra and LET spectra. These studies will be bench-marked with data taken at existing fast neutron therapy facilities. Results will also be compared with radiobiological studies to further support beam quality ptimization. These simulations, anchored by this data, will then be used to determine what parameters might be optimized to take full advantage of the unique LET properties of fast neutron beams. This paper will present preliminary work in generating energy and LET spectra for the Fermilab fast neutron therapy facility.

43 PARTICLE ACCELERATORS↗

Comparison of Integral Parameter Estimated Uncertainties in Fast Neutron Systems with COMMARA-2.1 and COMMARA-2.0 Covariance Data

This paper shows the main differences between the COMMARA-2.0 and COMMARA-2.1 evaluated covariance data in the uncertainty estimation of integral parameters of interest for a large number of typical innovative fast neutron systems. The study provides some guidelines to the nuclear data evaluators on which materials and which reaction types need to be evaluated most accurately to achieve reliable results in computational analyses of similar systems. The assessment of the quality and reliability of the covariance data is outside the scope of the study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid polystyrene and deuterated polystyrene light output response to fast neutrons

The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

47 OTHER INSTRUMENTATION↗

Design and expected performance of a fast neutron attenuation probe for light element density measurements

In this paper, we present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20–30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Lastly, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5–10% level for a two hour scan time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-Neutron Activation of Long-Lived Isotopes in Enriched Ge

We measured the production of 57Co, 54Mn, 68Ge, 65Zn, and 60Co in an sample of Ge enriched in isotope 76 due to high-energy neutron interactions. These isotopes are critical in understanding background in Ge detectors used for double-beta decay experiments. These isotopes are produced by cosmogenic-neutron interactions in the detectors while they reside on the Earth's surface. We compared the measured production to that predicted by cross-section calculations based on CEM03.02. The cross section calculations over-predict our measurements by approximately a factor of 2-3 depending on isotope. We then use the measured cosmic-ray neutron ux and our results to predict the cosmogenic production rate with an accuracy near 15%.

Environmental Molecular Sciences Laboratory↗

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗