Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Boron nitride neutron detector with the ability for detecting both thermal and fast neutrons

The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Fast-Neutron Irradiator and the Fast-Flux Tube Irradiation Fixtures at the Pennsylvania State Breazeale Reactor

Accurate knowledge of the neutron spectrum at a nuclear research reactor is a prerequisite for planning irradiation experiments, as well as for evaluating irradiation exposure results. The neutron-flux spectrum in the fast-neutron irradiator (FNI) and the fast-flux tube (FFT) irradiation fixtures at the Pennsylvania State Breazeale Reactor (PSBR) were characterized using the multi-foil neutron activation method. These irradiation fixtures make use of graded shielding to produce unique neutron fields. Multiple foil sets were irradiated in the fixtures with different exposure times and reactor powers to understand the stability over a wide range of operating conditions. Measured results were evaluated against a MCNP6 simulation to produce a measurement-informed neutron flux-energy spectrum for each fixture using STAYSL_PNNL. Simulated estimates of the FNI fixture, a newer fixture (~25 years old), demonstrated excellent agreement with measured results; the FFT did not. Thermal neutron measurements from the FFT suggest there is additional thermal leakage not captured in the simulation model. In conclusion, possible explanations for the discrepancy include burn-out or degradation (i.e., micro-cracking, gaps, etc.) in the boral and cadmium liners over the lifetime of the fixture (~40 years old).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Evaluation of the Starfire nGen-350 DD Neutron Generator for use with the Fast Neutron Coincidence Collar

The Starfire Industries nGen-350 DD neutron generator has been developed for use with the Fast Neutron Coincidence Collar (FNCL). The generator was adapted from the nGen-310 model generator by Starfire to accommodate an International Atomic Energy Agency (IAEA) request to incorporate a neutron yield stabilization mechanism. An nGen-350 generator was obtained by Oak Ridge National Laboratory (ORNL) for evaluation as a potential neutron interrogation source replacement for Am(Li) in the FNCL. This report provides a summary of the performance of the nGen-350.

43 PARTICLE ACCELERATORS↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

181 Ta - fast neutron evaluation [Slides]

Reliable fast-neutron evaluation can be entirely encapsulated in the reaction model and related input. Ta181 is a particularly relevant case due to extraordinary coverage of various observables by differential experiments that offer much help and relatively little headache. Differences from the similar ENDF/B-VIII evaluation include: more advanced modeling (CC OMP, MSD, MSC, decay schemes), more careful selection of models and parameters, new experimental data, and isomers. Overall, improved agreement with differential data and hints of better performance in integral testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗