Construction and evaluation of a nude fast-response cold-cathode ionization gage
Construction and evaluation of nude fast-response cold cathode ionization gauge for pressure measurement
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Construction and evaluation of nude fast-response cold cathode ionization gauge for pressure measurement
High sensitivity fast-response laser detection system, describing microwave response photoelectric detector with amplification and mixing functions
Fast-response coil drive circuit, for electromagnetic torque motors, reduces the inductive coil time constant with a minimum of circuit sophistication. The low-cost modulator servoamplifier is used with a compatible preamplifier stage which provides the servo-loop function of summing, adjustable gain and compensation.
Limit criteria for determining the dynamic performance capabilities of high performance, fast-response (greater than 100 Hz) electrohydraulic servosystems are presented. A detailed analysis of the maximum load locus of these systems is used as a basis for the derivation of improved limit criteria. These criteria predict the maximum performance limits caused by system nonlinearities and physical limitations. The criteria are applied to experimental data to verify their validity. Design criteria which assist in the selection of system components for optimal performance are also discussed.
Thin film thermal radiation detector noting construction, calibration, performance, error sources and advantages of pyroelectric over thin film gauges
Frequency-to-analog converter has a fast response time and a low ripple. The circuit uses a frequency-to-pulse converter which provides two pulse trains, both at the same frequency as that of the input signal, but with a 10 microsecond difference between the trains.
Thin film thermal radiation detector noting construction, calibration, performance, error sources and advantages of pyroelectric over thin film gauges
Six-cup, low-inertia anemometer combines high resolution and fast response with a unique ability to sense only the horizontal component of the winds fluctuating rapidly in three dimensions. Cup assemblies are fabricated of expanded polystyrene plastic.
Design and analysis of modular servoamplifier for fast response electrohydraulic control systems
Analysis of a typical nonlinear electrohydraulic servo-model establishes the dynamic-performance capabilities of servo-actuation systems.
Implementations of a state-plane-trajectory control law for energy storage dc-to-dc converters are presented. Performance characteristics of experimental voltage step-up converter systems employing these implementations are reported and compared to theoretical predictions.
A recently proposed state-trajectory control law for a family of energy-storage dc-to-dc converters has been implemented for the voltage step-up configuration. Two methods of realization are discussed; one employs a digital processor and the other uses analog computational circuits. Performance characteristics of experimental voltage step-up converters operating under the control of each of these implementations are reported and compared to theoretical predictions and computer simulations.
Dynamic performance analysis of fast-response fuel control valve for air breathing engine research
To extend the compatibility evaluation of candidate materials in oxygen, a high-pressure oxygen impact tester has been designed, developed, and installed at NASA/MSFC, Huntsville, Alabama. The tester has an operating range from ambient to 69,000 newton/sq m (10,000 psig) pressures and from the normal boiling point of liquid oxygen to 394 K (121 C) temperatures. The tester was designed to deliver 97.63 joules (72 ft-lb) of impact energy; however, variable height and weight can be achieved for threshold analysis. The system is completely remote and highly automated to furnish safe, reliable operation. High-frequency, fast-response instrumentation capabilities are provided to ensure maximum information output with the hope of minimizing the number of tests required for material acceptance.
Shock-tube experiments have been conducted to study the nonequilibrium gas-surface interaction which occurs when a thick shock wave in argon reflects from a coplanar, heat-conducting wall. Fast-response instrumentation was used to monitor variations in temperature and normal stress on the surface of the shock-tube end wall during and immediately following reflection of the incident shock wave. The laboratory observations are compared with computer predictions obtained by Deiwert using the direct-simulation Monte Carlo method, and excellent agreement is obtained when a suitable average thermal accommodation coefficient is chosen for the wall surface.
The statistical properties of low-level wind-turbulence data were obtained with the model 1080 total vector anemometer and the model 1296 dual split-film anemometer, both manufactured by Thermo Systems Incorporated. The data obtained from the above fast-response probes were compared with the results obtained from a pair of Gill propeller anemometers. The digitized time series representing the three velocity components and the temperature were each divided into a number of blocks, the length of which depended on the lowest frequency of interest and also on the storage capacity of the available computer. A moving-average and differencing high-pass filter was used to remove the trend and the low frequency components in the time series. The calculated results for each of the anemometers used are represented in graphical or tabulated form.
The enhanced sonic boom or supersonic boom generated as a result of atmospheric refraction in threshold Mach number flights was recreated in a ballistic range by firing projectiles at low supersonic speeds into a stratified medium obtained by slowly injecting carbon dioxide into air. The range was equipped with a fast-response dynamic pressure transducer and schlieren photographic equipment, and the sound speed variation with height was controlled by regulating the flow rate of the CO2. The schlieren observations of the resulting flow field indicate that the generated shocks are reflected near the sonic cutoff altitude where local sound speed equals body speed, provided such an altitude exists. Maximum shock strength occurs very nearly at the point where the incident and reflected shocks join, indicating that the presence of the reflected shock may have an appreciable effect on the magnitude of the focus factor. The largest focus factor detected was 1.7 and leads to an estimate that the constant in the Guiraud-Thery scaling law should have a value of 1.30.
Under a Noise Addendum to the NASA Experimental Clean Combustor Program (ECCP) internal pressure fluctuations were measured during tests of JT9D combustor designs conducted in a burner test rig. Measurements were correlated with burner operating parameters using an expression relating farfield noise to these parameters. For a given combustor, variation of internal noise with operating parameters was reasonably well predicted by this expression but the levels were higher than farfield predictions and differed significantly among several combustors. For two burners, discharge stream temperature fluctuations were obtained with fast-response thermocouples to allow calculation of indirect combustion noise which would be generated by passage of the temperature inhomogeneities through the high pressure turbine stages of a JT9D turbofan engine. Using a previously developed analysis, the computed indirect combustion noise was significantly lower than total low frequency core noise observed on this and several other engines.