Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault injector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Beam Spill in Downstream Transport due to Injector Faults [PowerPoint]

We have investigated injector faults with numerical experiments. For this investigation we used the nominal tune that is also being used to assess beam stability. Beam spill in the DST due to a serious injector fault was evaluated using the LSP slice algorithm. Only the most serious fault investigated (-350 keV) caused beam spill in the DST. DST transport focusing solenoids limit the beam spill. Beam spill in the DST is the result of large halo caused by betatron oscillations of the mismatched beam. Bremsstrahlung radiation from the DST beam spill was estimated from Tom Martin scaling normalized to DARHT-I. In conclusion, Scorpius is reasonably safe from beam spill radiation in the DST due to injector faults.

43 PARTICLE ACCELERATORS↗

En echelon faults reactivated by wastewater disposal near Musreau Lake, Alberta

We use machine-learning and cross-correlation techniques to enhance earthquake detectability by two magnitude units for the earthquake sequence near Musreau Lake, Alberta, which is induced by wastewater disposal. This deep catalogue reveals a series of en echelon ~N–S oriented strike-slip faults that are favourably oriented for reactivation. These faults require only ~0.6 MPa overpressure for triggering to occur. Earthquake activity occurs in bursts, or episodes; episodes restricted to the largest fault tend to have earthquakes starting near the southern end (distant from injectors) and progressing northwards (towards the injectors). While most events are concentrated along these ~N–S oriented faults, we also delineate smaller faults. Together, these findings suggest pore pressure as the triggering mechanism, where a time-dependent increase in pore pressure likely caused these faults to progressively reawaken. Analysis of the ‘next record-breaking event’, a statistical model that forecasts the sequencing of earthquake magnitudes, suggests that the next largest event would be M L ~4.3. The seismically illuminated length of the largest fault indicates potential magnitudes as large as M w 5.3.

58 GEOSCIENCES↗

First Ever Polymer Flood Field Pilot To Enhance The Recovery Of Heavy Oils On Alaska’s North Slope - Pushing Ahead One Year Later

In June 2018 the team embarked on an ambitious project to address the slow development pace of Alaska’s 20+ billion barrels heavy oil resource via the first ever polymer flood pilot. Following the successful commencement of the pilot in August 2018, the field demonstration, supporting laboratory experiments and numerical simulation have steadily progressed. A significant amount of valuable data and lessons learned have been collected, and are reported in this paper. The ongoing pilot and the research activities is making headway toward the primary objective of validating the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. The pilot is conducted in two pre-existing pairs of horizontal injectors and producers in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field. A customized polymer blending and pumping unit injects HPAM polymer at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP. Supporting coreflood laboratory experiments have focused on quantification of polymer retention in the rock, and effect of injection water salinity, polymer, and their combinations on oil recovery. The injection and production response of the pilot flood pattern is utilized to develop a history matched reservoir simulation model for forecasting oil recovery beyond the pilot. Finally, specially designed laboratory experiments address anticipated operating concerns regarding post-polymer breakthrough such as oil-water separation efficiency and polymer induced fouling of heater tubes. Polymer has been injected continuously since startup except for two short equipment modification shutdowns, and more recently a prolonged disruption due to polymer hydration issues at the J-pad field site. Cumulatively, over 600,000 lbs. of polymer has been injected, corresponding to ~7%PV. The two producers show significant decrease in the water cut, gradually increasing oil rate, and no polymer breakthrough. Two main observations from the coreflood are a significant uncertainty in polymer retention values, and positive oil recovery response to low salinity water (2,600 mg/liter TDS). The heterogeneity in the flood pattern presents some challenges in obtaining a robust history matched simulation model. Experimental results on produced fluids treatment indicate the formation of a dense polymer deposit, at certain conditions, on heating tubes that can negatively impact the heat transfer efficiency. The scientific knowledge, including the lessons learned during unanticipated shutdowns, quality control, logistics and field data that is being acquired from this effort has referential value for other planned EOR projects. Finally, by all indications, the polymer field pilot is steadily progressing toward achieving the ultimate goal of unlocking the massive heavy oil resources on Alaska North Slope (ANS).

Dandekar, Abhijit↗

Bus repeater and bit injector for MIL-STD-1553/1760 communications bus

A fault insertion device (FID) comprises a transceiver and an FPGA. The transceiver receives signals from a MIL-STD-1553/1760 communications bus. The FPGA evaluates the signals received from the communications bus against a set of rules stored by the FPGA. Based upon the set of rules, the FPGA can selectively modify messages received from the communications bus prior to transmission to a remote terminal or a bus controller that is configured to communicate on the communications bus.

Krein, Jason P.↗

Development of a Smart Alarm System for the CEBAF Injector

RadiaSoft and Jefferson Laboratory are working together to develop a machine-learning-based smart alarm system for the CEBAF injector. Because of the injector’s large number of parameters and possible fault scenarios, it is highly desirable to have an autonomous alarm system that can quickly identify and diagnose unusual machine states. We present our work on artificial neural networks designed to identify such undesirable machine states. In particular, we test both auto-encoders and inverse models as possible tools for differentiating between normal and abnormal states. These models are being developed using both supervised and unsupervised learning techniques, and are being trained using CEBAF injector data collected during dedicated machine studies as well as during regular operations. Lastly, we discuss tradeoffs between the two types of models.

Abell, D. T.↗

A Smart Alarm for the CEBAF Injector

We present initial results from a proof-of-concept ?smart alarm? for the CEBAF injector. Because of the injector's large number of parameters and possible fault scenarios, it is highly desirable to have an autonomous alarm system that can quickly identify and diagnose unusual machine states. Our approach leverages a trained neural network to not only identify an anomalous machine state, but also to identify the root-cause by pinpointing the specific element or region responsible. We developed an inverse model trained on data collected during normal operations. Using the inverse model, measurements from the machine are used to compute machine settings, which are then compared to EPICS setpoints. Instances when predictions differ from EPICS setpoints by a user-defined threshold are flagged as anomalies, and the user is alerted to the issue. We present the results of our data collection efforts, model training and performance, and initial performance metrics.

Tennant, C.↗

Cognac Offshore Oil Field Case Study

This document is one of three offshore post-primary CO 2 enhanced oil recovery project case studies that compares the modeling results from an industry standard compositional simulator (“GEM”) and a variant of the FE/NETL CO 2 Prophet Model (CO 2 Prophet Model), which determined the CO 2 Prophet Model was able to reasonably represent the performance of the CO 2 flood modeled using the more sophisticated GEM. This case study uses the Cognac oil field J Sand, in the field’s Northeast fault block, using a line drive pattern design (one CO 2 injector and two production wells), for 10-year and 20-year injection scenarios. A version of the CO 2 Prophet Model is available on NETL’s website under the Collection Name: FE/NETL CO 2 Prophet Model.

02 PETROLEUM↗

Horn Mountain Offshore Oil Field Case Study

This document is one of three offshore post-primary CO 2 enhanced oil recovery project case studies that compares the modeling results from an industry standard compositional simulator (“GEM”) and a variant of the FE/NETL CO 2 Prophet Model (CO 2 Prophet Model), which determined the CO 2 Prophet Model was able to reasonably represent the performance of the CO 2 flood modeled using the more sophisticated GEM. This case study uses the Horn Mountain oil field NFB M Sand, in the field's North fault block, using three pairs of wells. Each pair of wells is a line drive pattern design (one CO 2 injector and one production well). Four 20-year injection scenarios were assessed, varying CO 2 injector well placements. A version of the CO 2 Prophet Model is available on NETL’s website under the Collection Name: FE/NETL CO 2 Prophet Model.

02 PETROLEUM↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Identification of potential CO 2 leakage pathways and mechanisms in oil reservoirs using fault tree analysis

Geological storage of CO 2 technologies has become an important and effective way to reduce the greenhouse gas emissions, especially when it is combined with CO 2 enhanced oil recovery (EOR), which can not only trap CO 2 but also enhance oil recovery. However, the risk of CO 2 leakage has always been a prominent issue. In this paper, the mechanisms and pathways of CO 2 leakage during geological storage in oil reservoirs were analyzed using fault tree analysis (FTR). Besides, monitoring technologies were discussed and deployed in a CO 2 EOR demonstration project. The analysis results showed that the sealing failures of oil producer and CO2 injector wells, like well cement failure and casing failure, are the main reasons for the CO 2 leakage, which has been observed in the oil field monitoring project. The monitoring results indicated that there is no large-scale CO 2 leakage, while relatively high and abnormal CO 2 concentration in soil gas near some wellbores are observed, which indicates there is some leakage of CO 2 through incomplete cement ring and well casing string. FTR results provide guidelines for monitoring and preventing of CO 2 leakage during geological storage in oil reservoirs. Finally, the near-surface monitoring methods, especially the soil gas monitoring technologies, can effectively detect the leakage of CO 2 , and are a proper method for CO 2 leakage monitoring.

58 GEOSCIENCES↗

Fault Injection for TensorFlow Applications

As machine learning (ML) has seen increasing adoption in safety-critical domains (e.g., autonomous vehicles), the reliability of ML systems has also grown in importance. While prior studies have proposed techniques to enable efficient error-resilience (e.g., selective instruction duplication), a fundamental requirement for realizing these techniques is a detailed understanding of the application’s resilience. In this work, we present TensorFI 1 and TensorFI 2, high-level fault injection (FI) frameworks for TensorFlow-based applications. TensorFI 1 and 2 are able to inject both hardware and software faults in any general TensorFlow 1 and 2 program respectively. Both are configurable FI tools that are flexible, easy to use, and portable. They can be integrated into existing TensorFlow programs to assess their resilience for different fault types (e.g., bit-flips in particular operations or layers). We use the TensorFI 1 and TensorFI 2 to evaluate the resilience of 12 and 10 ML programs written in TensorFlow, including DNNs used in the autonomous vehicle domain. The results give us insights into why some of the models are more resilient. We also measure the performance overheads of the two injectors, and present 4 case studies, two for each tool, to demonstrate their utility.

97 MATHEMATICS AND COMPUTING↗

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

Pore Pressure Diffusion and Onset of Induced Seismicity

The Raton Basin of Southern Colorado and Northern New Mexico experienced a significant increase in seismicity over the last several decades, including two M5+ earthquakes. The increase in seismicity started soon after an increase in wastewater disposal associated with coal-bed methane production. Twenty-nine wastewater injection wells have operated in the Basin, with several high-rate injectors located within a kilometer of the most seismically active regions. We developed a pore pressure model to investigate the relationship between pore pressure diffusion and onset of induced seismicity, with an emphasis on the Trinidad fault zones. Our model indicates that sufficient pore pressure increase had accumulated on the northern extent of the Trinidad fault zone to induce seismicity at the time of early-stage seismic activity. The hydrogeologic architecture of the Basin played a key role in controlling pore pressure perturbation. The basal sedimentary interval with moderately low diffusivity restricted vertical pore pressure diffusion, creating a substantial lag time between wells becoming active and the expression of perturbation in the fault zones. The spatiotemporal relationship between early-stage seismicity and wastewater injection in conjunction with modeled pore pressures suggests that the early-stage seismicity in the Raton Basin was likely triggered by pore pressure diffusion.

58 GEOSCIENCES↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

A 300 kA Pulsed Power Supply for LBNF

The Long Baseline Neutrino Facility (LBNF) will produce the worlds most intense neutrino beam. Three series connected magnetic horns will require 5kV, 300kA, 800$\mu$s pulses at a rate of 0.7Hz to focus the beam. Fermilab has designed and built pulsed high current supplies for horns in the past. Pulsed currents of 205 kA for Neutrinos at Main Injector (NuMI - NOvA), focusing a 120 GeV beam, and 170 kA for Booster Neutrino Beam (BNB - MiniBooNE) for focusing an 8 GeV beam have been operational for about 18 years. While the magnetic horns are expected to be replaced, the LBNF horn power supply is expected to last the lifetime of the project, 30 years. A resonant, half sine wave pulser was used for NuMI and BNB and has many practical advantages. The system has impedance limited fault currents by design, albeit large ones. That along with the resonant behavior means that thyristor switches are well suited. Many fault modes of the system have also been calculated. Several circuit changes were incorporated so that a single fault can be tolerated. The supply must be reversable to enable both neutrinos and anti-neutrinos to be produced. These reversal requirements required a significant amount of mechanical design and consideration to allow for quick reversal of all the semiconductors.

43 PARTICLE ACCELERATORS↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska North Slope – Producer Responses and Operational Lessons Learned

The US Department of Energy and Hilcorp Alaska, LLC are jointly cosponsoring a field pilot project entitled “First Ever Field Pilot on Alaska’s North Slope to Validate the Use of Polymer Floods for Heavy Oil Enhanced Oil Recovery (EOR).” The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on Alaska North Slope (ANS). Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot which was designed to acquire field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 using a custom made polymer mixing and pumping unit. Polymer solution properties such as concentration, viscosity, and filter ratio, have been closely monitored and adjusted as necessary. Operational procedures have been improved to ensure adequate injectivity and polymer propagation through the formation. Oil and water production is tested frequently to monitor water cut performance, and produced water is sampled and analyzed for polymer content. Tracers were pumped pre and post polymer injection startup to compare polymer flood breakthrough timing and sweep efficiency. Polymer injectivity of the horizontal wells drilled in the Schrader Bluff NB sand is found to be sufficient to replace the reservoir production voidage although there were some declines as high viscosity polymer swept the near wellbore region. Production data show significant reduction in water cut and the oil production rate has stabilized. No polymer production has been confirmed from the two horizontal producers after 22 months of polymer injection into the two supporting horizontal injectors. Tracer data show very low sweep efficiencies with waterflood alone, whereas significant improvement has been achieved with polymer flood. Many operational lessons have been learned and improvements have been made regarding polymer mixing, pumping, and onsite quality control, particularly in a challenging Arctic environment. Adequate polymer injection rate can be achieved with diligent monitoring and quality assurance of the properties of the injected polymer solution.

Ning, Samson↗