A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems [SWR-24-13]

This software provides a data-driven approach for efficiently identifying high impedance faults (HIFs) in distribution systems. To tackle the nonlinearity of the voltage current trajectory of HIFs, we first formulate linear least squares problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations.

Zhou, Yuqi↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Interplay Between Distributed Bulk Plasticity and Local Fault Slip in Evolving Fault Zone Complexity

Abstract We numerically investigate the role of plastic strain accumulation on the mechanical response of a planar strike‐slip fault. Our models show that fault‐zone strength significantly impacts the ensuing sequence of earthquakes. Weaker fault zones accumulating more plastic strain promote more complexity in the seismicity pattern through aperiodic earthquake occurrences and intermittent episodes of rupture and arrest. However, if the fault zone strength is high enough, the overall earthquake sequence is characterized by periodic fault‐spanning events. We find that both the fault normal stress and the fault geometric profile evolve throughout the earthquake sequence, suggesting a self‐roughening mechanism. Despite the significant impact of plasticity on the fault response, the width of the plastically deforming region in the fault zone is small compared to the fault length. Our results suggest a rich behavior in dynamically evolving fault zones and support the need for further high‐resolution studies of the highly non‐linear near‐fault region.

Geology↗

End-to-end microgrid protection using distributed data-driven methods

This paper introduces an end-to-end microgrid protection framework that offers real-time system monitoring, fault-related decision making, and circuit breaker control. This is achieved through the design of distributed data-driven techniques based on the support vector machine method, where each relay is responsible for distributed data collection, fault detection, fault localization, and fault isolation. Local communication is established among neighboring relays, fostering cooperative fault localization and isolation. This decentralized design not only reduces the computational and communication requirements but also enables the adaptability of each relay under varying operational dynamics. The proposed end-to-end protection framework was validated using MATLAB/Simulink simulations on a 100% renewable microgrid, achieving an accuracy of 93.1% with response time of 0.0523 s, in protecting against a range of fault scenarios that are characterized by various types, locations, impedances, load conditions, photovoltaic power levels, and microgrid operating modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

The effect of shear strain and shear localization on fault healing

The seismic cycle of repeated earthquake failure requires that faults regain frictional strength during the interseismic phase, when the fault is locked or undergoing quasi-static creep. Fault healing plays a central role in determining earthquake stress drop, recurrence interval, elastic radiation frequency and other source parameters. In particular, the longer a fault remains quasi-stationary, the stronger it becomes and the larger the potential stress drop can be for the next event. Here, we address the role of shear strain and strain localization on fault healing and healing rate. We performed slide-hold-slide friction experiments on quartz gouge in the double-direct shear configuration for shear strain up to 25 and hold times from 10 to 1000 s. The results show that both healing and healing rate increase nonlinearly with increasing shear strain. Frictional healing scales with volumetric strain within the laboratory fault zone. Using the volumetric strain upon reshear as a proxy for strain localization, we demonstrate that the capacity of a fault to heal is directly proportional to shear bandwidth and degree of strain localization. The more the deformation is localized, the higher are the healing and healing rate, and thus, the fault strength. Our data provide a framework for understanding variations in fault strength over the seismic cycle and the role of brecciation and strain localization on spatiotemporal variations in fault strength.

58 GEOSCIENCES↗

An Autonomous Distributed Fault-Tolerant Local Positioning System

We describe a fault-tolerant, GPS-independent (Global Positioning System) distributed autonomous positioning system for static/mobile objects and present solutions for providing highly-accurate geo-location data for the static/mobile objects in dynamic environments. The reliability and accuracy of a positioning system fundamentally depends on two factors; its timeliness in broadcasting signals and the knowledge of its geometry, i.e., locations and distances of the beacons. Existing distributed positioning systems either synchronize to a common external source like GPS or establish their own time synchrony using a scheme similar to a master-slave by designating a particular beacon as the master and other beacons synchronize to it, resulting in a single point of failure. Another drawback of existing positioning systems is their lack of addressing various fault manifestations, in particular, communication link failures, which, as in wireless networks, are increasingly dominating the process failures and are typically transient and mobile, in the sense that they typically affect different messages to/from different processes over time.

Mahyar R Malekpour↗

The influence of preexisting host rock damage on fault network localization

The transition from stable to unstable fracture propagation occurs when fractures begin to interact and link. Thus, fracture network coalescence controls how rocks and engineered structures fail. Here, to constrain the factors that influence localization in shear zones under brittle conditions, we build discrete element method models with a rough fault embedded in a shear zone. We add varying numbers of diffuse, randomly-placed weaknesses to examine the influence of diffuse damage on fracture network localization. The number of weaknesses controls the localization behavior of the fault network and the final fault geometry. We quantify localization using the Gini coefficient of the fracture volume, which measures the nonuniformity in a population. Each model generally increases in localization toward failure. However, models with more diffuse damage experience delocalization phases that are superimposed on the overall trend of increasing localization. The observed link between delocalization and host rock damage may help explain the varying localization of low magnitude seismicity in southern California. Models with more diffuse damage produce more complex fault geometries comprised of several parallel strands of wing cracks. The propagation of these wing cracks reduces the shear stress acting on the model boundaries, indicating that this fracture development increases the mechanical efficiency of the system.

58 GEOSCIENCES↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

Methodology for Designing Fault-Protection Software

A document describes a methodology for designing fault-protection (FP) software for autonomous spacecraft. The methodology embodies and extends established engineering practices in the technical discipline of Fault Detection, Diagnosis, Mitigation, and Recovery; and has been successfully implemented in the Deep Impact Spacecraft, a NASA Discovery mission. Based on established concepts of Fault Monitors and Responses, this FP methodology extends the notion of Opinion, Symptom, Alarm (aka Fault), and Response with numerous new notions, sub-notions, software constructs, and logic and timing gates. For example, Monitor generates a RawOpinion, which graduates into Opinion, categorized into no-opinion, acceptable, or unacceptable opinion. RaiseSymptom, ForceSymptom, and ClearSymptom govern the establishment and then mapping to an Alarm (aka Fault). Local Response is distinguished from FP System Response. A 1-to-n and n-to- 1 mapping is established among Monitors, Symptoms, and Responses. Responses are categorized by device versus by function. Responses operate in tiers, where the early tiers attempt to resolve the Fault in a localized step-by-step fashion, relegating more system-level response to later tier(s). Recovery actions are gated by epoch recovery timing, enabling strategy, urgency, MaxRetry gate, hardware availability, hazardous versus ordinary fault, and many other priority gates. This methodology is systematic, logical, and uses multiple linked tables, parameter files, and recovery command sequences. The credibility of the FP design is proven via a fault-tree analysis "top-down" approach, and a functional fault-mode-effects-and-analysis via "bottoms-up" approach. Via this process, the mitigation and recovery strategy(s) per Fault Containment Region scope (width versus depth) the FP architecture.

Barltrop, Kevin↗

Low-cost coding techniques for digital fault diagnosis

Published report discusses fault location properties of arithmetic codes. Criterion for effectiveness of given code is detection probability of local fault by application of checking algorithm to results of entire set of algorithms of processor. Report also presents analysis of arithmetic codes with low-cost check algorithm which possesses partial fault-location properties.

Avizienis, A. A.↗

Machine Learning Classification of Molten Salt Heat Exchanger Channel Plugging using Synthetic Data

This report addresses the requirements of Milestone M3.4 AI capability to identify and predict maintenance events. Development of digital twins (DT) for molten salt reactor (MSR) components is crucial for reducing operating and maintenance costs (O&M) and ensuring commercial viability of these reactors. Our focus is on development of DT for MSR primary system heat exchanger (HX), a critical component, the fault in which can reduce operating efficiency and force reactor shutdown. We are investigating the feasibility of a conceptual DT of HX consisting of internal distributed temperature sensing with fiber optics and machine learning (ML) algorithms to detect and localize faults. To determine the optimal approach to detection and localization of channel plugging, we benchmark seven different ML models: Logistic Regression, K-Nearest Neighbors (KNN), Gaussian Naïve Bayes, Support Vector Machines (SVM), Decision Tree Classifier, Random Forest Tree Classifier, and Feed-Forward Neural Network. ML algorithms are benchmarked using synthetic HX plugging data generated with computational fluid dynamics COMSOL software, with added brown noise to represent experimental noise. We show that the best performance is obtained with the Decision Tree classifier.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geodetic measurement of deformation in the central Mojave Desert, California

Data from triangulation and trilateration surveys made during 1934-1982 are used to calculate shear strain rates in the central Mojave Desert of California. For the region between the Helendale and Camp Rock faults the shear strain rate was determined to be 0.16 + or - 0.03 microstrain/yr, with maximum right-lateral shear strain occurring on a plane oriented N41 deg W + or - 5 deg. If this deformation is due to right-lateral motion across the northwest trending local faults, the average shear straining corresponds to a relative displacement of 6.7 + or - 1.3 mm/yr across this portion of the network, accounting for about 12 percent of the predicted 56 mm/yr of relative motion between the North Atlantic and Pacific plates. From the Camp Rock fault eastward across the network there is a transition from significant to very low strain rates. Examination of nine focal mechanisms and their relation to the local geology and the strain data suggests that most of the long-term displacement occurs on the major northwest trending faults oriented nearly along the direction of relative motion between the North American and Pacific plates. Secondary faulting, controlled by a Coulomb-Anderson failure mechanism or by slip on preexisting faults can account for the occurrence of earthquakes on faults of other orientations.

Sauber, Jeanne↗

Geological and vegetational applications of Shuttle Imaging Radar-B, Mineral County, Nevada

Multiple-incidence angle and multi-azimuth radar data were acquired from a Shuttle platform over test sites in Nevada in October 1984. An attempt was made to correlate these data with ground features for the purpose of evaluating the use of such data for geological and vegetational assessment. Standard ecological parameters with respect to the flora (community composition, dominance, and relative cover) were recorded in the field at the time of overflight. Although a total of 33 species representing 11 plant families were recognized, and plant cover ranged from 13 to 26 percent, radar data could not be used to separate plant communities. The signal return is more a function of abiotic conditions than vegetative characteristics. Illumination geometry plays an important role in the ability to detect strike-slip and dip-slip faults. Local incidence angle is the most important parameter, and SIR-B data takes with small incidence angles are superior for identifying certain styles of faulting. Look direction is critical for detecting faults with a dip-slip component. New structural features were not observed. Problems with radar antenna power and recording significantly affected data quality.

Borengasser, M. X.↗

Advancing the Limits of InSAR to Detect Crustal Displacement from Low-Magnitude Earthquakes through Deep Learning

Detecting surface deformation associated with low-magnitude (M w ≤ 5) seismicity using interferometric synthetic aperture radar (InSAR) is challenging due to the subtlety of the signal and the often challenging imaging environments. However, low-magnitude earthquakes are potential precursors to larger seismic events, and thus characterizing the crustal displacement associated with them is crucial for regional seismic hazard assessment. We combine InSAR time-series techniques with a Deep Learning (DL) autoencoder denoiser to detect the magnitude and extent of crustal deformation from the M w = 3.4 Gallina, New Mexico earthquake that occurred on 30 July 2020. Although InSAR alone cannot detect event-related deformation from such a low-magnitude seismic event, application of the DL method reveals maximum displacements as small as (±2.5 mm) in the vicinity of both the fault and earthquake epicenter without prior knowledge of the fault system. This finding improves small-scale displacement discernment with InSAR by an order of magnitude relative to previous studies. We additionally estimate best-fitting fault parameters associated with the observed deformation. The application of the DL technique unlocks the potential for low-magnitude earthquake studies, providing new insights into local fault geometries and potential risks from higher-magnitude earthquakes. This technique also permits low-magnitude event monitoring in areas where seismic networks are sparse, allowing for the possibility of global fault deformation monitoring.

58 GEOSCIENCES↗