Statistical Analysis of Feeder and Locational PV Hosting Capacity for 216 Feeders
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This paper describes methods that a distribution engineer could use to determine advanced inverter settings to improve distribution system performance. These settings are for fixed power factor, volt-var, and volt-watt functionality. Depending on the level of detail that is desired, different methods are proposed to determine single settings applicable for all advanced inverters on a feeder or unique settings for each individual inverter. Seven distinctly different utility distribution feeders are analyzed to simulate the potential benefit in terms of hosting capacity, system losses, and reactive power attained with each method to determine the advanced inverter settings.
One of the greatest challenges for the analysis of distribution systems is the high level of diversity across the world. For nearly 20 years the Test Feeder Working Group of the Distribution System Analysis Subcommittee has been developing distribution test feeders. The purpose of these test feeders is to provide openly-available models of distribution systems that reflect the diversity in systems and the analytic challenges they present. Because of their utility and accessibility, the test feeders have been used for a wide range of research, some of which they were not originally intended to cover. The purpose of this paper is to provide an overview of the variety of existing distribution systems, and to clarify the specific analytic challenges that each test feeder was originally designed to examine. Additionally, the paper will provide guidance on which feeders are best suited for various types of analysis. The purpose of this paper is to provide the original intent of the Working Group and to inform researchers so that they may make an informed decision on which of the test feeders are most appropriate for their work.
Biomass is a source of renewable energy and can undergo thermochemical processes to be converted into gaseous and liquid fuels. Thermal decomposition-induced biomass fouling on the screw feeder is a major challenge in preconversion of pyrolysis, leading to plugging of the feed line. Here, this work intends to gain fundamental understanding of the biomass fouling phenomena across the heat gradient on the screw feeder via a combination of materials characterization and thermal simulation. An actual screw feeder that failed because of biomass fouling was examined to reveal the deposit’s morphology, composition, and mechanical properties. Thermal simulations were developed for both the screw feeder and the wood particles being transported using a combined analytical and numerical approach. The simulated temperature profiles correlated well with the deposit observations, based on which potential mitigations were proposed from both the operation and screw design perspectives and supported by preliminary experimental validation.
This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.
As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.
Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.
Voltage regulators help maintain an acceptable voltage profile for the system. This paper discusses the effect of installing voltage regulators to the system to fix the voltage drop resulting from the electrical vehicles loading increase when they are being charged. The effect will be studied in the afternoon, when the peak load occurs, using the IEEE 34 bus test feeder. First, only one spot node is used to charge the electric vehicles while a voltage regulator is present. Second, five spot nodes are loaded at the same time to charge the electric vehicles while voltage regulators are installed at each node. After that, the impact of electric vehicles on distribution feeders that do not have voltage regulators will appear.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.
Abstract Plug‐screw feeders are critical in many industrial processes for compressing slurry materials via a rotating plug‐screw feeder. Over time, increasing plug‐screw feeder wear will eventually lead to catastrophic mechanical failure. Early detection of the wear state can prevent unplanned catastrophic failures resulting in operational shut‐downs, costly repairs, and most importantly the health and safety of workers. We present a theoretical basis for a noninvasive, in operando acoustic resonant technique to monitor the wear state of plug‐screw feeders. The technique is based on tracking the resonant acoustic modes of the plug‐screw feeder, which are sensitive to the plug‐screw feeder geometry, material, and operating conditions. We implemented a multivariate polynomial model to estimate the plug‐screw feeder wear state using multiple acoustic resonances by simulating the acoustic resonant modes for two categories of wear (tip and thread damage) that are common in plug‐screw feeders. Fitting multiple resonances to the polynomial model, we demonstrate accurate estimation of the total mass loss, as well as characterization of the type of damage (i.e., tip vs. thread). Current approaches for monitoring plug‐screw feeder wear rely on shutting down the operation and visually inspecting the plug‐screw feeder. The presented acoustic technique offers a noninvasive, in operando measurement approach that mitigates unplanned catastrophic failures. The acoustic resonance technique presented in the paper has a broad range of industrial applications including the Pharmaceutical, Mining, Integrated Biorefineries (IBR), and Additive Manufacturing industries, to name a few.
Automatic feeders are revolutionizing aquaculture by enabling precise and controlled feeding regimens that optimize growth, reduce feed waste, and enhance the overall efficiency of farming operations. Demand feeders provide some similar benefits but with feeding tailored to fish appetites and, in some cases, feed dispersal without electricity. This review explores the evolution, technological advancements, and applications of these feeders with a survey of recent research. It looks at common feeder designs and compares the pros and cons of five automatic feeder configurations in commercial use today. The article contrasts feeders and feed sizes for farmed species in different life stages and facilities, from hatcheries to ponds and offshore cages. It discusses the importance of species-tailored feeding strategies as well as impacts on fish behavior and health, nutrient delivery, and environmental sustainability. Incorporating sensors and on-site computing enables optimization in feeding algorithms that feeders then implement precisely and reliably. The review compiles results from multiple studies comparing growth rate, weight, and feed conversion ratio (FCR) outcomes from automatic feeders and demand feeders versus traditional hand-feeding regimens. The integration of feeders with real-time monitoring and data analytics is also discussed, highlighting future directions for research and adoption across the industry.
The screening process for DG interconnection procedures needs to be improved in order to increase the PV deployment level on the distribution grid. A significant improvement in the current screening process could be achieved by finding a method to classify the feeders in a utility service territory and determine the sensitivity of particular groups of distribution feeders to the impacts of high PV deployment levels. This report describes the utility distribution feeder characteristics in California for a large dataset of 8,163 feeders and summarizes the California feeder population including the range of characteristics identified and most important to hosting capacity. The report describes the set of feeders that are identified for modeling and analysis as well as feeders identified for the control group. The report presents a method for separating a utility's distribution feeders into unique clusters using the k-means clustering algorithm. An approach for determining the feeder variables of interest for use in a clustering algorithm is also described. The report presents an approach for choosing the feeder variables to be utilized in the clustering process and a method is identified for determining the optimal number of representative clusters.
This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.
This paper presents a novel, automated, generative adversarial networks (GAN) based synthetic feeder generation mechanism, abbreviated as FeederGAN. FeederGAN digests real feeder models represented by directed graphs via a deep learning framework powered by GAN and graph convolutional networks (GCN). Information of a distribution feeder circuit is extracted from its model input files so that the device connectivity is mapped onto the adjacency matrix and the device characteristics, such as circuit types (i.e., 3-phase, 2-phase, and 1-phase) and component attributes (e.g., length and current ratings), are mapped onto the attribute matrix. Then, Wasserstein distance is used to optimize the GAN and GCN is used to discriminate the generated graphs from the actual ones. A greedy method based on graph theory is developed to reconstruct the feeder using the generated adjacency and attribute matrices. Furthermore, our results show that the GAN generated feeders resemble the actual feeder in both topology and attributes verified by visual inspection and by empirical statistics obtained from actual distribution feeders.