SEARCH · Search NASA
Results for “fence”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fencing affects movement patterns of two large carnivores in Southern Africa
The erection of peripheral fences around protected areas has been shown to adversely affect the movement behavior, genetic connectivity and long-term viability of animal populations. However, fencing is also used extensively to reduce human encroachment, limit poaching activities, and mitigate human–wildlife conflicts. Limited information on the movement behavior of carnivores is available along the periphery of protected areas, particularly in semi-arid environments. To quantify the potential effects of the 824 km perimeter fence surrounding the Etosha National Park (Etosha, Namibia) on the movement and space use of carnivores, we collected GPS movement data from 36 lions (Panthera leo) and seven spotted hyenas (Crocuta crocuta) over a 14-year period. For these two apex carnivores, we measured the impact of the Etosha fence on their movements (step lengths and path straightness), calculated the likelihood of fence crossings, and evaluated the spatial–temporal characteristics of these crossings. Our results indicated that lions and hyenas moved faster (longer step lengths) when closer to the fence. Lions showed no variation in path straightness with respect to the fence but hyenas had straighter movement paths when closer to the fence. When moving within the vicinity of the fence, lions had a 9% likelihood of crossing the fence, while hyenas were much more likely (18%) to do so, which suggests that the Etosha fence was more permeable for hyenas than for lions. Fence crossings predominantly occurred at night for both species. Lions were more likely to cross the fence during the cold dry season (May–August) whereas hyenas crossed more often during the warm wet season (December–April). Female and adult lions had a higher probability of crossing the fence than males and subadults. These findings could be useful in the development of appropriate strategies to mitigate human–carnivore conflicts and thus promote the conservation of carnivores in multiple-use areas along the periphery of the park. Further research is needed to better elucidate the impact of perimeter fences on a broader suite of carnivores and other large mammals, including species-specific variation in the response to fences, as well as the economic benefits of fencing provided to local communities.
Phosphate tolerance of nitrogen-coordinated-iron-carbon (FeNC) catalysts for oxygen reduction reaction: A size-related hindrance effect
The greatest challenges facing the large – scale commercialization of the intermediate temperature phosphoric acid fuel cell (PAFC) technology are: (i) the high cost of Pt catalyst that is required to overcome the slow kinetics of oxygen reduction reaction (ORR) on the PAFC cathode, and (ii) deactivation of the Pt catalyst by exposure to the phosphoric acid electrolyte. Inexpensive carbon-based materials, particularly iron- spectroscopy is used to explore the phenomenon of phosphate poisoning nitrogen-coordinated carbon supported catalysts (FeNC), are promising cathodes for PAFCs. The higher ORR activation energy and phosphate poisoning resistance of FeNC present a clear advantage over the Pt-based commercial catalysts that are easily susceptible to deactivation after exposure to phosphate anions. While the immunity of FeNC catalysts to phosphate anion poisoning has been reported previously, this work explores the counter-intuitive and conditional nature of this poisoning resistance based on the properties of the carbon support used in the preparation of the FeNC catalyst. Additionally, a combination of electrochemical measurements with characterization experiments performed using X-ray photoelectron spectroscopy, infrared spectroscopy and in-situ X-ray absorption on FeNC catalysts synthesized from two different carbon supports. Results from these studies reveal a “size-related hindrance effect” wherein the ORR active Fe centers in FeNC remain inaccessible to larger anions such as phosphate when the Fe sites are present deeper inside the pores of a carbon support with high porosity. However, FeNC catalyst is poisoned by phosphate anions when synthesized using a carbon support with low porosity. This work helps gain insights into the nature of active sites in FeNC catalysts that will be useful in designing precious-metal free ORR catalysts for intermediate temperature fuel cell technologies.
Design of a physical security perimeter fencing system.
Design of a physical security perimeter fencing system requires that security designers provide effective detection, delay, and response functionalities with minimal nuisance alarms. In addition, the designers must take into considerations the security fence system life cycle cost (equipment and grounds maintenance), complexity of the terrain, safety, and environmental conditions (location of where the security fence will be installed). Often, these factors drive the security designers to design a perimeter intrusion detection and assessment system (PIDAS) that includes: (1) larger than desired footprint, (2) one or more animal control fences to minimize the nuisance alarm rate (NAR), and (3) clear zones and an isolation zone to facilitate intrusion detection and assessment by keeping the fence lines clear of vegetation, trash, and other objects that could impede the security system's performance. This paper presents a two-tier PIDAS design that focuses on effective performance specifically in high probability of detection and low NAR that minimizes cost and the footprint of the system.
Fencing direct memory access data transfers in a parallel active messaging interface of a parallel computer
Fencing direct memory access (`DMA`) data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including specifications of a client, a context, and a task, the endpoints coupled for data communications through the PAMI and through DMA controllers operatively coupled to segments of shared random access memory through which the DMA controllers deliver data communications deterministically, including initiating execution through the PAMI of an ordered sequence of active DMA instructions for DMA data transfers between two endpoints, effecting deterministic DMA data transfers through a DMA controller and a segment of shared memory; and executing through the PAMI, with no FENCE accounting for DMA data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all DMA instructions initiated prior to execution of the FENCE instruction for DMA data transfers between the two endpoints.
Fencing direct memory access data transfers in a parallel active messaging interface of a parallel computer
Fencing direct memory access (`DMA`) data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including specifications of a client, a context, and a task, the endpoints coupled for data communications through the PAMI and through DMA controllers operatively coupled to segments of shared random access memory through which the DMA controllers deliver data communications deterministically, including initiating execution through the PAMI of an ordered sequence of active DMA instructions for DMA data transfers between two endpoints, effecting deterministic DMA data transfers through a DMA controller and a segment of shared memory; and executing through the PAMI, with no FENCE accounting for DMA data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all DMA instructions initiated prior to execution of the FENCE instruction for DMA data transfers between the two endpoints.
Fencing direct memory access data transfers in a parallel active messaging interface of a parallel computer
Fencing direct memory access (`DMA`) data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including specifications of a client, a context, and a task, the endpoints coupled for data communications through the PAMI and through DMA controllers operatively coupled to segments of shared random access memory through which the DMA controllers deliver data communications deterministically, including initiating execution through the PAMI of an ordered sequence of active DMA instructions for DMA data transfers between two endpoints, effecting deterministic DMA data transfers through a DMA controller and a segment of shared memory; and executing through the PAMI, with no FENCE accounting for DMA data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all DMA instructions initiated prior to execution of the FENCE instruction for DMA data transfers between the two endpoints.
Fencing data transfers in a parallel active messaging interface of a parallel computer
Fencing data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including a specification of data communications parameters for a thread of execution on a compute node, including specifications of a client, a context, and a task; the compute nodes coupled for data communications through the PAMI and through data communications resources including at least one segment of shared random access memory; including initiating execution through the PAMI of an ordered sequence of active SEND instructions for SEND data transfers between two endpoints, effecting deterministic SEND data transfers through a segment of shared memory; and executing through the PAMI, with no FENCE accounting for SEND data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all SEND instructions initiated prior to execution of the FENCE instruction for SEND data transfers between the two endpoints.
Fencing data transfers in a parallel active messaging interface of a parallel computer
Fencing data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including a specification of data communications parameters for a thread of execution on a compute node, including specifications of a client, a context, and a task; the compute nodes coupled for data communications through the PAMI and through data communications resources including at least one segment of shared random access memory; including initiating execution through the PAMI of an ordered sequence of active SEND instructions for SEND data transfers between two endpoints, effecting deterministic SEND data transfers through a segment of shared memory; and executing through the PAMI, with no FENCE accounting for SEND data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all SEND instructions initiated prior to execution of the FENCE instruction for SEND data transfers between the two endpoints.
Fencing data transfers in a parallel active messaging interface of a parallel computer
Fencing data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint comprising a specification of data communications parameters for a thread of execution on a compute node, including specifications of a client, a context, and a task, the compute nodes coupled for data communications through the PAMI and through data communications resources including a deterministic data communications network, including initiating execution through the PAMI of an ordered sequence of active SEND instructions for SEND data transfers between two endpoints, effecting deterministic SEND data transfers; and executing through the PAMI, with no FENCE accounting for SEND data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all SEND instructions initiated prior to execution of the FENCE instruction for SEND data transfers between the two endpoints.
Fencing network direct memory access data transfers in a parallel active messaging interface of a parallel computer
Fencing direct memory access (`DMA`) data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including specifications of a client, a context, and a task, the endpoints coupled for data communications through the PAMI and through DMA controllers operatively coupled to a deterministic data communications network through which the DMA controllers deliver data communications deterministically, including initiating execution through the PAMI of an ordered sequence of active DMA instructions for DMA data transfers between two endpoints, effecting deterministic DMA data transfers through a DMA controller and the deterministic data communications network; and executing through the PAMI, with no FENCE accounting for DMA data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all DMA instructions initiated prior to execution of the FENCE instruction for DMA data transfers between the two endpoints.
Fencing network direct memory access data transfers in a parallel active messaging interface of a parallel computer
Fencing direct memory access (`DMA`) data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint including specifications of a client, a context, and a task, the endpoints coupled for data communications through the PAMI and through DMA controllers operatively coupled to a deterministic data communications network through which the DMA controllers deliver data communications deterministically, including initiating execution through the PAMI of an ordered sequence of active DMA instructions for DMA data transfers between two endpoints, effecting deterministic DMA data transfers through a DMA controller and the deterministic data communications network; and executing through the PAMI, with no FENCE accounting for DMA data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all DMA instructions initiated prior to execution of the FENCE instruction for DMA data transfers between the two endpoints.
Fencing data transfers in a parallel active messaging interface of a parallel computer
Fencing data transfers in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI including data communications endpoints, each endpoint comprising a specification of data communications parameters for a thread of execution on a compute node, including specifications of a client, a context, and a task, the compute nodes coupled for data communications through the PAMI and through data communications resources including a deterministic data communications network, including initiating execution through the PAMI of an ordered sequence of active SEND instructions for SEND data transfers between two endpoints, effecting deterministic SEND data transfers; and executing through the PAMI, with no FENCE accounting for SEND data transfers, an active FENCE instruction, the FENCE instruction completing execution only after completion of all SEND instructions initiated prior to execution of the FENCE instruction for SEND data transfers between the two endpoints.
Mass production of high-performance single atomic FeNC electrocatalysts via sequenced ultrasonic atomization and pyrolysis process
Mass production of highly efficient, durable, and inexpensive single atomic catalysts is currently the major challenge associated with the oxygen reduction reaction (ORR) for fuel cells. In this study, we develop a general strategy that uses a simple ultrasonic atomization coupling with pyrolysis and calcination process to synthesize single atomic FeNC catalysts (FeNC SACs) at large scale. The microstructure characterizations confirm that the active centers root in the single atomic Fe sites chelating to the four-fold pyridinic N atoms. The identified specific Fe active sites with the variable valence states facilitate the transfer of electrons, endowing the FeNC SACs with excellent electrochemical ORR activity. The FeNC SACs were used as cathode catalysts in a homemade Zn-air battery, giving an open-circuit voltage (OCV) of 1.43 V, which is substantially higher than that of commercial Pt/C catalysts. This study provides a simple approach to the synthesis of single atomic catalysts at large scale.
Use of H2S to Probe the Active Sites in FeNC Catalysts for the Oxygen Reduction Reaction (ORR) in Acidic Media
H2S has been used as a probe molecule both in an “in situ” poisoning experiment and in intermediate-temperature heat-treatment steps during and after the preparation of FeNC catalysts in an attempt to analyze its effect on their ORR activity. The heat treatments were employed either on the ball-milled precursor of FeNC or after the Ar-NH3 high temperature heat treatments. ORR activity of the H2S-treated catalysts was seen to be significantly lower than the sulfur-free catalysts, whether the sulfur exposure was during a half-cell testing, or as an intermediate-temperature exposure to H2S. The incorporation of sulfur species and interaction of Fe with sulfur were confirmed by characterization using XPS, EXAFS, TPO, and TPD. This study provides crucial evidence regarding differences in active sites in FeNC versus nitrogen-containing carbon nanostructured (CNx) catalysts.
Evolution of N-Coordinated Iron–Carbon (FeNC) Catalysts and Their Oxygen Reduction (ORR) Performance in Acidic Media at Various Stages of Catalyst Synthesis: An Attempt at Benchmarking
The objective of this study was to understand the role of iron and the heat treatment steps involved in nitrogen-coordinated iron-carbon (FeNC) catalyst synthesis. We have studied the oxygen reduction reaction (ORR) performance of these catalysts as they evolve from their most crude and inactive form to their most active form. Electrochemical half-cell and fuel cell tests suggest that the presence of Fe was crucial in these samples. The high-temperature heat treatment (once in argon and then in ammonia) at temperatures ≥950 °C were also critical in imparting these catalysts with their highest activity; however, significant loss of activity was observed with cycling and potential hold at 0.5 V for 100 h. In addition, acid-washing after the first or the second pyrolysis steps produced a marked decrease in ORR activity relative to their unwashed counterparts. We also report findings from our efforts towards benchmarking FeNC catalysts for oxygen reduction reaction electrocatalysis. Specifically, we focus on correlating the specific kinetic current (iK) at 0.75 V to electrochemically accessible surface area (EASA) and roughness factor (RF) determined from electrochemical double layer capacitance measurements. 57 Fe Mössbauer spectroscopy was employed to shed light into the nature of active sites in FeNC catalysts and provide insights into their deactivation behavior caused by acid-washing. The results suggest planar FeN 4 doublet (Fe 2+ , low spin) as an active site in these materials, which may be leached away in acid, explaining their decreased activity after acid washing. Results for characterization experiments using X-ray photoelectron spectroscopy, temperature programmed oxidation and X-ray absorption spectroscopy, superconducting quantum interference device magnetometry are also presented.
TU-F-CAMPUS-T-02: Vernier Picket Fence Test: A Non-Imaging Method to Localize the Radiation Isocenter with Submillimeter Accuracy
Purpose: The purpose of this study is to propose a new non-imaging method to localize the radiation isocenter with submillimeter accuracy. Methods: The Vernier picket fence (VPF) is a multileaf collimator (MLC) picket fence sequence in which the fence spacing is 1/N smaller than the detector spacing of the QA phantom, where N is the magnification factor, typically set to 10 or 20. Similar to reading a Vernier caliper, the user can easily achieve the resolution of 1/N of the detector spacing by visually inspecting the maximum signal. To achieve higher accuracy, a Gaussian model was used to interpolate the peak position, which can fall between adjacent detectors. In two separate tests, precise MLC offsets and imprecise couch offsets were applied to a 2D detector array (MapCheck, Sun Nuclear Corp., Melbourne, Florida) to introduce setup errors. Two vertical VPF fields were delivered with collimator angles at 0° and 90° to detect the lateral and longitudinal setup errors, respectively. For a rotational QA phantom, an additional lateral VPF field is needed to detect the vertical setup error for three-dimensional capabilities. Results: With N set to 20 and a detector spacing of 5 mm for MapCheck, the resolution of the VPF’s visual analysis is 0.25 mm. With the Gaussian interpretation, the VPF can achieve an accuracy of 0.02 mm, as shown by the MLC offset test. The couch offset test measured the couch hysteresis and demonstrated that the setup error detected by the VPF differed from the ExacTrac™ (Brainlab AG, Feldkirchen, Germany) optical tracking by 0.055 mm in the lateral direction and 0.041 mm in the longitudinal direction on average. The VPF was also shown to be feasible in the vertical direction as well. Conclusion: This study verified the VPF as a non-imaging method to localize the radiation isocenter with submillimeter accuracy. Funding is in part by the Portland Chapter of the Achievement Rewards for College Scientists. The content is solely the responsibility of the authors, and does not necessarily represent the official views of the sponsors. The authors declare no conflict of interest.