Search NASA⌕ Search

SEARCH · Search NASA

Results for “fenestration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fenestrated Thoracic Endovascular Aortic Repair Using Physician-Modified Stent Grafts (PMSGs) in Zone 0 and Zone 1 for Aortic Arch Diseases

Purpose: To evaluate the outcomes of fenestrated thoracic endovascular aortic repair (f-TEVAR) using physician-modified stent grafts (PMSGs) in zone 0 and zone 1 for aortic arch diseases. Methods: f-TEVAR using PMSGs in Z0 and Z1 was performed on ten high-risk patients for open surgery from November 2015 to September 2017. Indications were complicated acute type B dissection (ABAD) with retrograde dissection involving the mid-arch (n = 1), distal arch aneurysms (n = 3), mid-arch aneurysms of the inner arch curvature (n = 3) and penetrating aortic ulcer located in the mid- or proximal arch (n = 3). Pre-, intra- and postoperative clinical data were recorded. Results: The median patient age was 61 (range 45–81) years, and 9 (90%) patients were men. Ten PMSGs (Medtronic Valiant stent grafts, n = 1; Relay thoracic stent grafts, n = 4; Cook TX2 device, n = 5) were deployed. PMSGs were deployed from Z0 and Z1 in 5 and 5 patients, respectively. Double small fenestrations for the left subclavian artery (LSA) and the left common carotid artery (LCCA), respectively, were created in 3 patients. Triple small fenestrations for the innominate artery (IA), the LCCA and the LSA, respectively, were created in 2 patients. One large fenestration for both the IA and the LCCA combined with one small fenestration for the LSA was created in 3 patients. One large fenestration for the LCCA combined with one small fenestration for the LSA was created in 2 patients. Posterior diameter-reducing ties were added to all the devices except to one Valiant stent graft. All but 2 patients underwent elective procedure. Median duration for stent graft modifications was 105 (range 90–125) min. The technical success rate was 90%. Overall mortality was 10% (1/10). One patient died of sudden cardiac arrest intraoperatively after the deployment of the PMSG and all the supra-aortic branch stents. Mean operative time was 106.0 ± 43.0 min, and fluoroscopy time was 30.6 ± 22.9 min. There were no type I or type III endoleaks, perioperative neurological complications or spinal cord ischemia. Median length of stay was 8 (range 4–35) days. Nine patients survived at mean 13.3 (range 6.0–19.0) months follow-up. Retrograde dissection occurred in one patient of Z0 group 40 days post-f-TEVAR and resolved after open repair. During follow-up, all target vessels remained patent without fenestration-related type I or III endoleaks. Conclusions: f-TEVAR using PMSGs in Z0 and Z1 for the treatment of aortic arch diseases in high-risk patients is feasible in the hands of experienced operators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commercial Building Fenestration Market Study

This study characterizes and assesses the U.S. commercial fenestration market. It analyzes a groundbreaking amount of data that will ultimately support an estimate of national savings potential of energy efficient fenestration products in commercial applications to demonstrate the benefits of efficient façade and fenestration systems. This study provides data and analysis on: commercial fenestration market and fenestration selection process, installed commercial fenestration stock across the U.S. and fenestration sales estimates, and current commercial building fenestration codes and market trends of installation to or above code.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fenestration System Performance Research, Testing, and Evaluation

The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be done to continues research to improve existing ratings and develop new ones. NFRC needs to continue the work it has begun in several nations to implement the NFRC rating system that has been introduced. Many nations are eager to accept the expertise NFRC can offer to achieve energy conservation goals. NFRC looks forward to a continues partnership with the US Department of Energy to cooperatively achieve both.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Stereoscopic Visualization of Fenestrated Stent Grafts

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Fenestration Technique for Abdominal Aortic Dissection Membranes Using a Combination of a Needle Re-entry Catheter and the 'Cheese-wire' Technique

Purpose: This study was designed to demonstrate the applicability of a combined needle-based re-entry catheter and 'cheese-wire' technique for fenestration of abdominal aortic dissection membranes. Methods: Four male patients (mean age: 65 years) with acute complicated aortic type B dissections were treated at our institution by fenestrating the abdominal aortic dissection membrane using a hybrid technique. This technique combined an initial membrane puncture with a needle-based re-entry catheter using a transfemoral approach. A guidewire was passed through the re-entry catheter and across the membrane. Using a contralateral transfemoral access, this guidewire was then snared, creating a through-and-through wire access. The membrane was then fenestrated using the cheese-wire maneuver. Results: We successfully performed: (a) membrane puncture; (b) guidewire passage; (c) guidewire snaring; and (d) cheese-wire maneuver in all four cases. After this maneuver, decompression of the false lumen and acceptable arterial inflow into the true lumen was observed in all cases. The dependent visceral arteries were reperfused. In one case, portions of the fenestrated membrane occluded the common iliac artery, which was immediately and successfully stented. In another case, long-standing intestinal hypoperfusion before the fenestration resulted in reperfusion-related shock and intraoperative death of the patient. Conclusions: The described hybrid approach for fenestration of dissection membranes is technically feasible and may be established as a therapeutic method in cases with a complicated type B dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fenestration system energy performance research, implementation, and international harmonization

The research conducted by the NFRC and its contractors adds significantly to the understanding of several areas of investigation. NFRC enables manufacturers to rate fenestration energy performance to comply with building energy codes, participate in ENERGY STAR, and compete fairly. NFRC continuously seeks to improve its ratings and also seeks to simplify the rating process. Several research projects investigated rating improvement potential such as • Complex Product VT Rating Research • Window 6 and Therm 6 Validation Research Project • Complex Product VT Rating Research Conclusions from these research projects led to important changes and increased confidence in the existing NFRC rating process. Conclusions from the Window 6/Therm 6 project will enable window manufacturers to rate an expanded array of products and improve existing ratings. Some research lead to an improved new rating method called the Component Modeling Approach. A primary goal of the CMA was a simplification of the commercial energy rating process to increase participation and make the commercial industry more competitive and code compliant. The project below contributed towards CMA development: • Component Modeling Approach Condensation Resistance Research NFRC continues to implement the Component Modeling Approach program. The program includes the CMA software tool, CMAST, and several procedural documents to govern the certification process. This significant accomplishment was a response the commercial fenestration industry’s need for a simplification of the present NFRC energy rating method (named site built). To date, most commercial fenestration is self-rated by a variety of techniques. The CMA enables commercial fenestration manufacturers to rate according to the NFRC 100/200 as most commercial energy codes require. International Harmonization NFRC achieved significant international harmonization success by continuing its licensing agreements with the Australian Fenestration Rating Council and the Association of Architectural Aluminum Manufacturers of South Africa (AAAMSA) to produce NFRC certified product ratings in their respective nations. NFRC worked in several other nations to introduce the NFRC ratings system: • India • China • Japan • Canada • Thailand • South Africa • Brazil • Korea NFRC attended or hosted several meetings in each of these nations establishing academic, commercial, industrial, and governmental contacts. NFRC presented the NFRC process and then necessary infrastructure steps necessary to achieve harmonization with the NFRC labeling system. NFRC looks forward to continued work toward harmonization in these nations and potentially others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two Wire System and Modified Olive Tip to Facilitate Implantation of Fenestrated TEVAR in Patient with Proximal Descending Aortic Pathology: First Two Cases

Introduction: Although Fenestrated TEVAR (F-TEVAR) has been considered to be a more physiologic approach to treat proximal descending aortic pathology, its application is still limited due to availability, cost and technical difficulties. We introduce a new design of fenestrated stent graft with a new delivery system and successfully performed first in human implantation in two patients, one with an aortic aneurysm and one with an acute aortic dissection. Materials and Methods: The design of these two wires fenestrated stent graft include creation of an additional lumen at the side of the olive tip during manufacture, from which an additional wire can be introduced for a side branch passing into the fenestration, running inside the stent graft and exit the delivery sheath through additional hub. The two wires will facilitate delivery and deployment of the stent graft. One patient with descending aortic aneurysm and another with Stanford B aortic dissection is included in this first in human study. Results: The aneurysm and dissection were completely excluded immediately after the TEVAR. Six month follow up CT showed good position of the stent graft and patent LSA in both patients. In the patient with aortic dissection, expansion of the true lumen and partial thrombosis of the false lumen was seen. Conclusions: This is a report of a two wire system in 2 patients with distal aortic arch pathology demonstrating a good technical and clinical success using pre-cannulated fenestrations through a modified nose cone olive. Level of Evidence: Level 4, report of two cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Performance Commercial Fenestration Framing Systems

A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial fenestration framing systems, by investigating new technologies that would improve the thermal performance of aluminum frames, while maintaining their structural and life-cycle performance. The project targeted an improvement of over 30% (whole window performance) over conventional commercial framing technology by improving the performance of commercial framing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using digital imaging to assess spectral solar-optical properties of complex fenestration materials: A new approach in video-goniophotometry

A large variety of angularly selective fenestration systems have been developed in the past two decades and show great potential in improving visual comfort while reducing energy consumption, especially when combined with spectrally selective properties. Such systems include light-redirecting glazing, shading, film coatings, reflectors and others. To assess the potential of these systems accurately and reliably, one needs to be able to predict in detail how they modify the energy, direction and spectral make-up of solar radiation. For this assessment, spectral (wavelength-dependent) Bidirectional Transmission or Reflection Distribution Functions are used, usually referred to as BTDFs or BRDFs, or more generally BSDFs for Scattering Functions. To enable a faster, cheaper, and continuous investigation of these properties over most of the solar spectrum (400-1700 nm), an innovative goniospectrometric instrument has been created, relying on digital imaging, on light collection by an ellipsoidal half-transparent mirror, and on a filtering method in the visible range to generate spectral radiometric BSDFs. This so-called Heliodome instrument is described in this paper. It enables the performance of new fenestration technologies to be assessed in terms of lighting and solar gains management potential. The rotating table also serves as a heliodon, an architectural design tool for visualizing sunlight distribution inside a scale model and performing analyses on appropriate sun control strategies. The Heliodome's major innovations compared to other devices are to enable an analysis of both the visible and the near-infrared portions of the solar spectrum, to provide spectral as well as photometric light distribution data, and to ensure a continuous investigation of the transmitted or reflected light in a time-efficient way. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Certification and Rating of Attachments for Fenestration Technologies

In the U.S., windows still represent a significant energy savings opportunity in residential and commercial buildings, and for decades the United States Department of Energy (DOE) has funded fenestration software tools, analysis, studies, and the National Fenestration Rating Council (NFRC). Despite significant developments in window technology and recognition of efficient products, studies conducted by the U.S. Energy Information Administration and Pacific Northwest National Laboratory (PNNL) found that approximately 64% of U.S. homes currently have inefficient windows. Window attachments (interior and exterior blinds, shades, storm windows, awnings, shutters, etc.) can offer a more cost-effective option to improve the energy performance of residential and commercial windows. In previous years, the window attachment industry attempted to work with the NFRC to generate a window attachment rating program, but was unable to access funding or technical resources necessary to address window attachments, which added many levels of complexity on top of NFRC’s scope of windows and glazing. Starting in 2014, the DOE Office of Energy Efficiency and Renewable Energy (EERE) funded the Window Coverings Manufacturing Association (WCMA) to develop the Attachments Energy Rating Council (AERC) along with policies and procedures to deliver an unbiased, credible, comparable, relevant, and cost-effective window attachment energy rating program for the residential and commercial sectors over a four-year period. This project was created because there were no consistent and credible performance rating mechanisms for assessing the energy performance of window attachments. Without a standardized approach, consumers found it difficult to make informed and comparative decisions about the energy performance of window attachments, and utilities faced challenges offering incentives for energy-efficient attachments. The goal of this project was two-fold: to develop procedures to rate and certify the energy performance of window attachments and to create an educational, consumer-facing Certified Products Website (CPW) to help consumers and other stakeholders make more informed window attachments purchasing decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WINDOW-WALL INTERFACE CORRECTION FACTORS: THERMAL MODELING OF INTEGRATED FENESTRATION AND OPAQUE ENVELOPE SYSTEMS FOR IMPROVED PREDICTION OF ENERGY USE

The boundary conditions for thermal modeling of fenestration systems assume an adiabatic condition between the fenestration system installed and the opaque envelope system. This theoretical adiabatic boundary condition may not be appropriate owing to heat transfer at the interfaces, particularly for aluminum- framed windows affixed to metal- framed walls. In such scenarios, the heat transfer at the interface may increase the discrepancy between real world thermal indices and laboratory measured or calculated indices based on NFRC Rating System.This paper discusses the development of window-wall Interface Correction Factors (ICF) to improve energy impacts of building envelope systems

99 GENERAL AND MISCELLANEOUS↗

Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance

We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AngioVac Aspiration for Paradoxical Emboli Protection through a Fenestrated Fontan During Central Venous Thrombus Manipulation

This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use of the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Visceral Transplant Pseudoaneurysms Using Physician-Modified Fenestrated Stent Grafts: Initial Experience

Pseudoaneurysms after visceral transplantation represent a significant risk to patients. We report the successful treatment of three transplant (pancreas, liver and kidney) artery anastomotic pseudoaneurysms using physician-modified fenestrated endovascular stent grafts. In all cases, surgical repair was considered high risk and would have compromised the arterial supply to the graft. The endovascular approach in all cases obviated the need for surgical intervention and maintained graft arterial supply.

62 RADIOLOGY AND NUCLEAR MEDICINE↗