Search NASA⌕ Search

SEARCH · Search NASA

Results for “ferrofluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Sink-float ferrofluid separator applicable to full scale nonferrous scrap separation

Design and performance of a ferrofluid levitation separator for recovering nonferrous metals from shredded automobiles are reported. The scrap separator uses an electromagnet to generate a region of constant density within a pool of ferrofluid held between the magnetic poles; a saturated kerosene base ferrofluid as able to float all common industrial metals of interest. Conveyors move the scrap into the ferrofluid for separation according to density. Results of scrap mixture separation studies establish the technical feasibility of relatively pure aluminum alloy and zinc alloy fractions from shredded automobile scrap by this ferrofluid levitation process. Economic projections indicate profitable operation for shredders handling more than 300 cars per day.

Source record↗

The Ferrofluids Story

A new Ferrofluidics exclusion seal promises improvement in controlling "fugitive emissions" -vapors that escape into the atmosphere from petroleum refining and chemical processing facilities. These are primarily volatile organic compounds, and their emissions are highly regulated by the EPA. The ferrofluid system consists of a primary mechanical seal working in tandem with a secondary seal. Ferrofluids are magnetic liquids - fluids in which microscopic metal particles have been suspended, allowing the liquid to be controlled by a magnetic force. The concept was developed in the early years of the Space program, but never used. Two Avco scientists, however, saw commercial potential in ferrofluids and formed a company. Among exclusion seal commercial applications are rotary feedthrough seals, hydrodynamic bearings and fluids for home and automotive loudspeakers. Ferrofluidics has subsidiaries throughout the world.

Source record↗

High-Temperature Ferrofluids Based on Molten Salts

Molten metal chloride salts are promising candidates for advanced heat transfer fluids in generation IV nuclear reactors and beyond. However, research on the magnetic properties of suspended metallic nanoparticles at elevated temperatures is scarce, and there have been no attempts to develop a high-temperature, molten salt based ferrofluid. Such a ferrofluid would enable in situ manipulation of both the physical and thermal properties of the fluid via an external magnetic field. This study examines molten salt based ferrofluids comprised of metallic cobalt nanoparticles dispersed in molten metal chloride salts. High-temperature magnetometry and magneto-thermogalvometric measurements were conducted to evaluate the magnetic characteristics of the ferrofluid. Further analysis was conducted through a combination of microscopy, spectroscopy, solubility tests, and diffraction measurements. Furthermore, the metallic cobalt nanoparticles exhibited a notable degree of chemical stability and sustained magnetism from 25 to 800 °C when suspended in NaCl–MgCl 2 and KCl–ZnCl 2 mixtures.

Cobalt↗

Model-predictive optimal control of ferrofluidic microrobots in three-dimensional space

Ferrofluid microrobots have emerged as promising tools for minimally invasive medical procedures. Their unique properties to navigate complex fluids and reach otherwise inaccessible regions of the human body have enabled new applications in targeted drug delivery, tissue engineering, and diagnostics. Here, this paper proposes a model-predictive controller for the external magnetic manipulation of ferrofluid microrobots in three dimensions (3D). The internal optimization routine of the controller determines appropriate changes in the applied electromagnetic field to minimize the deviation between the actual and desired trajectories of the microrobot. A linear system governing locomotion is derived and used as the equality constraints of the optimization problems associated with the feedback index. In addition to ferrofluid droplets, the controller presented in this work may be applied to other magnetically-pulled microrobots. Several experiments are performed to validate the controller and showcase its ability to adapt to changes in system parameters such as the desired tracking trajectory and the size, orientation, deformation, and velocity of the microrobot. The accuracy of the controller is analyzed for each experiment, and the average error is found to be within 0.25 mm for small velocities. An additional experiment is performed to demonstrate significant improvement over a PID controller that is optimally tuned using Bayesian optimization. The results presented in this paper suggest that the proposed control algorithm could enable new microrobotic capabilities in minimally invasive medical procedures, lab-on-a-chip applications, and microfluidics.

60 APPLIED LIFE SCIENCES↗

Passive Magnetic Bearing With Ferrofluid Stabilization

A new class of magnetic bearings is shown to exist analytically and is demonstrated experimentally. The class of magnetic bearings utilize a ferrofluid/solid magnet interaction to stabilize the axial degree of freedom of a permanent magnet radial bearing. Twenty six permanent magnet bearing designs and twenty two ferrofluid stabilizer designs are evaluated. Two types of radial bearing designs are tested to determine their force and stiffness utilizing two methods. The first method is based on the use of frequency measurements to determine stiffness by utilizing an analytical model. The second method consisted of loading the system and measuring displacement in order to measure stiffness. Two ferrofluid stabilizers are tested and force displacement curves are measured. Two experimental test fixtures are designed and constructed in order to conduct the stiffness testing. Polynomial models of the data are generated and used to design the bearing prototype. The prototype was constructed and tested and shown to be stable. Further testing shows the possibility of using this technology for vibration isolation. The project successfully demonstrated the viability of the passive magnetic bearing with ferrofluid stabilization both experimentally and analytically.

Jansen, Ralph↗

Dynamics of Single Chains of Suspended Ferrofluid Particles

We present an experimental study of the dynamics of isolated chains made of super-paramagnetic particles under the influence of a magnetic field. The motivation of this work is to understand if the chain fluctuations exist and, if it does, how does the fluctuation affect chain aggregation. We find that single chains strongly fluctuate and that the characteristic frequency of their fluctuations is inversely proportional to the magnetic field strength. The higher the field the lower the characteristic frequency of the chain fluctuations. In the high magnetic field limit, chains behave like rigid rods without any internal motions. In this work, we used ferrofluid particles suspended in water. These particles do not have any intrinsic magnetization. Once a magnetic field is applied, a dipole moment is induced in each particle, proportional to the magnetic field. A dipolar magnetic interaction then occurs between particles. If dipole-dipole magnetic energy is higher than the thermal energy, the result is a structure change inside the dipolar fluid. The ratio of these two energies is expressed by a coupling constant lambda as: lambda = (pi(a(exp 3))(chi(exp 2))(mu(sub 0))(H(sub 0))(exp 2))/18kT Where a is the particle radius, mu(sub 0) is the vacuum magnetic permeability, H(sub 0) the applied magnetic field, k the Boltzmann constant and T the absolute temperature. If lambda > 1, magnetic particles form chains along the field direction. The lateral coalescence of several chains may form bigger aggregates especially if the particle volume fraction is high. While many studies and applications deal with the rheological properties and the structural changes of these dipolar fluids, this work focuses on the understanding of the chain dynamics. In order to probe the chain dynamics, we used dynamic light scattering (DLS) in self-beating mode as our experimental technique. The experimental geometry is such that the scattering plane is perpendicular to the magnetic field. Therefore, only motions in this plane are probed. A very dilute sample of a ferrofluid emulsion with a particle volume fraction of 10(exp -5) is used in this experiment. We chose such a low volume fraction to avoid multiple light scattering as well as lateral chain-chain aggregation. DLS measures the dynamic structure factor S(q,t) of the sample (q is the scattering wave vector, t is the time). In the absence of the magnetic field, identical particles of ferrofluid droplets are randomly distributed and S(q,t) reduces to exp(-q(exp 2)2D(sub 0)t). D(sub 0)=(kT/(6(pi)(eta)(a)) is the diffusion coefficient of Brownian particles (where Xi = (6(pi)(eta)(a)) is the Stokes frictional coefficient of a spherical particle in a fluid of viscosity eta). If interactions or polydispersity can not be ignored, an effective diffusion coefficient is introduced. Formally, D(sub eff) is defined as: D(sub eff) = - q(exp -2) partial derivative of (ln(S(q,t)) with respect to time, as t goes to 0. D(sub eff) reduces to D(sub 0) if no interactions and only a few particles size are present. Therefore, we can use DLS to measure particle size. The particle radius was found to be a=0.23 mu m with 7% of polydispersity. In this case, if we vary the scattering angle theta (and so q) we do not have any change in the measured diffusion coefficient: it is q-independent. When a magnetic field is applied, particles aggregate into chains if lambda > 1. We first studied the kinetics of the chain formation when lambda = 406. At a fixed scattering angle, we measured diffusion coefficient D(sub eff) as a function of time. Experimentally, we find that D(sub eff) decreases monotonously with time. Physically, this means that chains are becoming longer and longer. Since we are only sensitive to motions in the scattering plane and since chains have their main axis perpendicular to this plane, the measured diffusion coefficient is the trans-verse diffusion coefficient. We can relate D(sub eff) to the mean number of particles per chain N(t) at a given time and to the diffusion coefficient of an isolated particle D(sub 0) as D(sub eff)=f(N(t))D(sub 0). Since f(N) is known from other recent work, N can be expressed as a function of the time. We found a square root dependency: N(t) proportional to the square root of t. As expected for very low volume fraction, this behavior is characteristic of a diffusion-limited aggregation as suggested by several authors and by our previous work. In this study, we focus on the dependence of the effective diffusion coefficient on the scattering angle and the magnetic field strength. After the magnetic field is applied (lambda = 406) for a long time, typically 6 hours, kinetics of chain formation becomes very slow. Chain size does not vary much over the next hour period. Thus, we can perform different interesting experiments. First, at a fixed magnetic field, we measure the effective diffusion coefficient as a function of the scattering angle (from 5 to 130 deg). Our results show that the measured diffusion coefficient increases linearly with the scattering angle: D(sub eff) proportional to q. If we do the same experiment for different lambda values, D(sub eff) depends on lambda as D(sub eff) proportional to lambda(exp -1/2). We also find for different lambda values that the same asymptotic D(sub eff) value is obtained when q approaches zero. The angle dependency of D(sub eff) suggests that an additional motion exists besides chain drifting. Chain size is constant during experiment, which was verified by measuring the same diffusion coefficient at the beginning and at the end of the angle switching. If chains are rigid, D(sub eff) is independent of q. Therefore, we found that D(sub eff) not only measures the motion of the entire chain but also its internal fluctuations. These internal motions are the fluctuations of the particles in the chain. To understand the q dependency of D(sub eff), let us look at the probing length used. In our study, the characteristic length scale probed is l=2pi/q which is in the range of 0.9<l/a<20. When l is much larger than the particle radius (l/a going to infinity) we are mainly sensitive to the center of mass diffusion of the chain. D(sub eff) is then the diffusion of the entire chain and depends only on N but not on q and lambda. The value D(sub eff) allows us to obtain the number of particles per chain N. In the opposite limit (i.e. l/a < 1), we are sensitive to motions on the size of individual particles. The main contributions to the measured diffusion coefficient come from internal motions of the chains (i.e. particles' fluctuations inside the chain). We investigated also the effect of the chain size on D(sub eff). For the same value of the magnetic interaction lambda and different chain sizes, we found that the slope of D(sub eff) versus q decreases when N increases as a power law D(sub eff) proportional to N(exp -0.7). This is an important behavior because this means that the longer the chain the slower its internal fluctuations besides the whole chain motion.

Cutillas, S.↗

Ferrofluid separator for nonferrous scrap separation

Behavior of nonmagnetic objects within separator is essentially function of density, and independent of size or shape of objects. Results show close agreement between density of object and apparent density of ferrofluid required to float it. Results also demonstrate that very high separation rates are achievable by ferrofluid sink-float separation.

Kaiser, R.↗

Anomalous attenuation of ultrasound in ferrofluids under the influence of a magnetic field

Ultrasonic wave propagation has been studied in a water-base ferrofluid by pulse-echo methods. A commercial box-car integrator was used to measure the change in attenuation due to an external magnetic field applied at various angles relative to the ultrasonic propagation vector. Anomalous results were obtained when the attenuation was plotted as a function of the magnetic field strength. As the field increased, the attenuation reached a maximum and then decreased to a flat minimum before it approached saturation at a field of 2 KG. This variation of attenuation with magnetic field cannot be explained from the simple picture derivable from the work of McTague on the viscosity of ferrofluids. In no case was the viscosity seen to decrease with field, nor was the oscillatory behavior observed. The results of this study were compared with the theory developed by Parsons.

Isler, W. E.↗

Shape-induced superstructure formation in concentrated ferrofluids under applied magnetic fields

The field-induced ordering of concentrated ferrofluids based on spherical and cuboidal maghemite nanoparticles is studied using small-angle neutron scattering, revealing a qualitative effect of the faceted shape on the interparticle interactions as shown in the structure factor and correlation lengths. Whereas a spatially disordered hard-sphere interaction potential with a short correlation length is found for ~9 nm spherical nanoparticles, nanocubes of a comparable particle size exhibit a more pronounced interparticle interaction and the formation of linear arrangements. Analysis of the anisotropic two-dimensional pair distance correlation function gives insight into the real-space arrangement of the nanoparticles. On the basis of the short interparticle distances found here, oriented attachment, i.e. a face-to-face arrangement of the nanocubes, is likely. The unusual field dependence of the interparticle correlations suggests a field-induced structural rearrangement.

36 MATERIALS SCIENCE↗

Ferrofluidic solenoid with axial and radial displacement

New design is proposed for ferrofluidic solenoid with low magnetic flux leakage. Solenoid consists of a coil centered within a football-shaped elastomeric capsule filled with a ferromagnetic fluid. Fluid replaces the solid, movable core of conventional solenoids, and elastomeric capsule acts as return spring.

Sabelman, E. E.↗

Ferrofluid Would Seal Linear-Motion Valve

Proposed valve employs ferrofluid to make tight seal. Seal requires no precisely machined parts, and hand lapping of valve seats are unnecessary. Magnetic fluid fills gap between shaft and annular pole piece in chamber wall. Precise shaft fit is not necessary.

Chandler, J. A.↗

The Use of Ferrofluids to Model Materials Processing (MSFC Center Director's Discretionary Fund)

Many crystals grown in space have structural flaws believed to result from convective motions during the growth phase. The character of these instabilities is not well understood but is associated with thermal and solutal density variations near the solidification interface in the presence of residual gravity and g-jitter. To study these instabilities in a separate, controlled space experiment, a concentration gradient would first have to be artificially established in a timely manner as an initial condition. This is generally difficult to accomplish in a microgravity environment because the momentum of the fluid injected into a test cell tends to swirl around and mix in the absence of a restoring force. The use of magnetic fields to control the motion and position of liquids has received recent, growing interest. The possibility of using the force exerted by a non-uniform magnetic field on a ferrofluid to not only achieve fluid manipulation but also to actively control fluid motion makes it an attractive candidate for space applications. This paper describes a technique for quickly establishing a linear or exponential fluid concentration gradient using a magnetic field in place of gravity to stabilize the deployment. Also discussed is a photometric technique for measuring the concentration profile using light attenuation. Although any range of concentrations can be realized, photometric constraints impose some limitations on measurements. Results of the ground-based experiments indicate that the species distribution is within 3 percent of the predicted value.

Leslie, F.↗