Search NASA⌕ Search

SEARCH · Search NASA

Results for “fiber matrix interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An analysis of fiber-matrix interface failure stresses for a range of ply stress states

A graphite/bismaleimide laminate was prepared without the usual fiber treatment and was tested over a wide range of stress states to measure its ply cracking strength. These tests were conducted using off-axis flexure specimens and produced fiber-matrix interface failure data over a correspondingly wide range of interface stress states. The absence of fiber treatment, weakened the fiber-matrix interfaces and allowed these tests to be conducted at load levels that did not yield the matrix. An elastic micromechanics computer code was used to calculate the fiber-matrix interface stresses at failure. Two different fiber-array models (square and diamond) were used in these calculations to analyze the effects of fiber arrangement as well as stress state on the critical interface stresses at failure. This study showed that both fiber-array models were needed to analyze interface stresses over the range of stress states. A linear equation provided a close fit to these critical stress combinations and, thereby, provided a fiber-matrix interface failure criterion. These results suggest that prediction procedures for laminate ply cracking can be based on micromechanics stress analyses and appropriate fiber-matrix interface failure criteria. However, typical structural laminates may require elastoplastic stress analysis procedures that account for matrix yielding, especially for shear-dominated ply stress states.

Crews, J. H.↗

Fiber composite materials: A survey of fiber matrix interface mechanics

Report is described which discusses mechanism of load transfer from matrix to fiber through interface and effects of interface on composite structural integrity. Theoretical considerations are supplemented with experimental data. General trends and significant points are illustrated graphically.

Chamis, C. C.↗

Determination of fiber-matrix interface failure parameters from off-axis tests

Critical fiber-matrix (FM) interface strength parameters were determined using a micromechanics-based approach together with failure data from off-axis tension (OAT) tests. The ply stresses at failure for a range of off-axis angles were used as input to a micromechanics analysis that was performed using the personal computer-based MICSTRAN code. FM interface stresses at the failure loads were calculated for both the square and the diamond array models. A simple procedure was developed to determine which array had the more severe FM interface stresses and the location of these critical stresses on the interface. For the cases analyzed, critical FM interface stresses were found to occur with the square array model and were located at a point where adjacent fibers were closest together. The critical FM interface stresses were used together with the Tsai-Wu failure theory to determine a failure criterion for the FM interface. This criterion was then used to predict the onset of ply cracking in angle-ply laminates for a range of laminate angles. Predictions for the onset of ply cracking in angle-ply laminates agreed with the test data trends.

Naik, Rajiv A.↗

Closed-form analysis of fiber-matrix interface stresses under thermo-mechanical loadings

Closed form techniques for calculating fiber matrix (FM) interface stresses, using repeating square and diamond regular arrays, were presented for a unidirectional composite under thermo-mechanical loadings. An Airy's stress function micromechanics approach from the literature, developed for calculating overall composite moduli, was extended in the present study to compute FM interface stresses for a unidirectional graphite/epoxy (AS4/3501-6) composite under thermal, longitudinal, transverse, transverse shear, and longitudinal shear loadings. Comparison with finite element results indicate excellent agreement of the FM interface stresses for the square array. Under thermal and longitudinal loading, the square array has the same FM peak stresses as the diamond array. The square array predicted higher stress concentrations under transverse normal and longitudinal shear loadings than the diamond array. Under transverse shear loading, the square array had a higher stress concentration while the diamond array had a higher radial stress concentration. Stress concentration factors under transverse shear and longitudinal shear loadings were very sensitive to fiber volume fraction. The present analysis provides a simple way to calculate accurate FM interface stresses for both the square and diamond array configurations.

Naik, Rajiv A.↗

The effect of multiple compliant layers at the fiber-matrix interface on residual thermal stresses in metal matrix composites

The large mismatch in thermoelastic properties of the fiber and matrix phases in advanced metal matrix composites, coupled with high consolidation temperatures, produces severe residual stresses that can be large enough to initiate microcracks in the matrix phase adjacent to the fiber/matrix interface. Previous investigations have demonstrated that the use of a compliant interfacial layer between fiber and matrix phases has the potential for reducing these residual stresses. In this paper, the influence of multiple compliant layers in reducing residual thermal stresses is investigated.

Pindera, Marek-Jerzy↗

Fiber-matrix interface failures

Interface fractures of aluminum-graphite composites under transverse loading are expected to occur within the graphite fibers, but very near the interface. Residual stresses in aluminum, reinforced with the new high modulus pitch-based fibers, are much lower than would be expected based on simple elasticity calculations. The excess stress may be relaxed by shearing internal to the fibers or at the interface rather than by plastic flow of the matrix. The internal shearing also occurs during repeated thermal cycling of these composites; the fibers are repeatedly intruded, then extruded, during repeated temperature excursions.

Rabenberg, Lew↗

Fatigue damage criteria - Matrix, fibers and interfaces of continuous fiber reinforced metal matrix composites

Continuous fiber reinforced metal matrix composites (MMC) are projected for use in high temperature, stiffness critical parts that will be subjected to cyclic loadings. Depending on the relative fatigue behavior of the fiber and matrix, and the interface properties, the failure modes of MMC can be grouped into four catagories: (1) matrix dominated, (2) fiber dominated, (3) self-similar damage growth, and (4) fiber/matrix interfacial failures. These four types of damage are discussed and illustrated by examples. The emphasis is on the fatigue of unnotched laminates.

Johnson, W. S.↗

Investigation of interfacial shear strength in a SiC fibre/Ti-24Al-11Nb composite by a fibre push-out technique

A fiber push-out technique applied at several sample thicknesses was used to determine both the debond shear stress and the frictional shear stress at the fiber-matrix interface at room temperautre for a unidirectional SiC fiber-reinforced T-24Al-11Nb (in at. pct) composite prepared by a powder cloth technique. The push-out technique measures the separate contributions of bond strength and friction to the mechanical shear strength at the fiber-matrix interface. It was found that the fiber-matrix bond shear strength of this material is significantly higher than the fiber-matrix frictional shear stress (119.2 and 47.8 MPa, respectively).

Eldridge, J. I.↗

Effects of High-Temperature Annealing in Air on Hi-Nicalon Fiber-Reinforced Celsian Matrix Composites

BN/SiC-coated Hi-Nicalon fiber-reinforced celsian matrix composites (CMC) were annealed for 100 h in air at various temperatures to 1200 C, followed by flexural strength measurements at room temperature. Values of yield stress and strain, ultimate strength, and composite modulus remain almost unchanged for samples annealed up to 1100 C. A thin porous layer formed on the surface of the 1100 C annealed sample and its density decreased from 3.09 to 2.90 g/cu cm. The specimen annealed at 1200 C gained 0.43 wt%, was severely deformed, and was covered with a porous layer of thick shiny glaze which could be easily peeled off. Some gas bubbles were also present on the surface. This surface layer consisted of elongated crystals of monoclinic celsian and some amorphous phase(s). The fibers in this surface ply of the CMC had broken into small pieces. The fiber-matrix interface strength was characterized through fiber push-in technique. Values of debond stress, alpha(sub d), and frictional sliding stress, tau(sub f), for the as-fabricated CMC were 0.31+/-0.14 GPa and 10.4+/-3.1 MPa, respectively. These values compared with 0.53+/-0.47 GPa and 8.33+/-1.72 MPa for the fibers in the interior of the 1200 C annealed sample, indicating hardly any change in fiber-matrix interface strength. The effects of thermal aging on microstructure were investigated using scanning electron microscopy. Only the surface ply of the 1200 C annealed specimens had degraded from oxidation whereas the bulk interior part of the CMC was unaffected. A mechanism is proposed explaining the various steps involved during the degradation of the CMC on annealing in air at 1200 C.

Bansal, Narottam P.↗

Interface control and mechanical property improvements in silicon carbide/titanium composites

Several composite systems made of titanium matrix reinforced with silicon carbide fiber were investigated to obtain a better understanding of composite-degradation mechanisms and to develop techniques to minimize loss of mechanical properties during fabrication and in service. Emphasis was on interface control by fiber or matrix coatings. X-ray diffraction studies on planar samples showed that the formation of titanium silicides was greatly inhibited by the presence of aluminum or Ti3A1 layers at the fiber-matrix interface, with the Ti3A1 being more effective in reducing the reactions. Fiber studies showed that coating the fiber with a 1-micron-thick layer of aluminum improved the as-fabricated strength of a stoichiometric SiC fiber and reduced the fiber degradation during exposure to composite-fabrication conditions. Applying an interfacial barrier by coating the matrix foils instead of the fibers was found to be an effective method for improving composite strength. Reducing the fabrication temperature also resulted in significant improvements in composite strengths. Good-quality, well-consolidated composites were fabricated at temperatures well below those currently used for SiC-Ti composite fabrication.

Brewer, W. D.↗

Effective thermal conductivity of composites with fibre-matrix debonding

Debonding of the fiber-matrix interface is a major cause for the degradation of the mechanical properties and the loss of thermal conductivity of fiber-reinforced composites. This paper discusses two analytical approaches for modeling the thermal conduction problem of composites. One is based on the concept of modeling the thermal barrier by an equivalent heat transfer coefficient at the fiber-matrix interface, as described by Hasselman and Johnson (1987) and Benveniste and Miloh (1986). The other approach, suggested by Hatta and Taya (1986), is by treating a composite with debonded interface as a coated-fiber composite. The major advantage of the latter aproach is that the thickness of the fiber coating can be realistically modeled depending upon the extent of degradation of the composite with the thermal conductivity of the coating as that of air.

Fadale, T. D.↗

Transverse ductility of metal matrix composites

The role of the fiber matrix interface bond on the transverse ductility of continuous fiber reinforced composites has been investigated. Two specific systems have been considered: an Aluminum alloy matrix reinforced by Alumina fibers, characterized by a strong interface and a Titanium alloy reinforced by coated Silicon Carbide fibers, characterized by a weak interface. A micro-mechanical study indicates that the bond condition has a significant effect on the state of stress in the matrix which in turn dictates the available matrix ductility. The micro-mechanical predictions are in good agreement with the experimental results for the two systems.

Gunawardena, S. R.↗

Effects of Interface Modification on Mechanical Behavior of Hi-Nicalon Fiber-Reinforced Celsian Matrix Composites

Unidirectional celsian matrix composites having approx. 42 volume percent of uncoated or BN/SiC-coated Hi-Nicalon fibers were tested in three-point bend at room temperature. The uncoated fiber-reinforced composites showed catastrophic failure with strength of 210 +/- 35 MPa and a flat fracture surface. In contrast, composites reinforced with BN/SiC-coated fibers exhibited graceful failure with extensive fiber pullout. Values of first matrix cracking stress and strain were 435 +/- 35 MPa and 0.27 +/- 0.01 %, respectively, with ultimate strength as high as 960 MPa. The elastic Young's modulus of the uncoated and BN/SiC-coated fiber-reinforced composites were measured as 184 q 4 GPa and 165 +/- 5 GPa, respectively. Fiber push-through tests and microscopic examination indicated no chemical reaction at the uncoated or coated fiber-matrix interface. The low strength of the uncoated fiber-reinforced composite is probably due to degradation of the fibers from mechanical surface damage during processing. Because both the coated and uncoated fiber reinforced composites exhibited weak interfaces, the beneficial effect of the BN-SiC dual layer is primarily the protection of fibers from mechanical damage during processing.

Bansal, Narottam P.↗

Microstructure of a SiC/Ti-15-3 composite

A continuous SiC-fiber-reinforced titanium (Ti-15V-3Cr-3Sn-3A1) composite was metallographically examined. Several methods for examining composite materials were investigated and documented. Polishing techniques for this material are described. An interference layering method was developed to reveal the structure of the fiber, the reaction zone, and various phases within the matrix. Microprobe and TEM analyses were performed on the fiber-matrix interface. Detailed descriptions of the fiber distribution and the microstructure of the fiber and matrix are presented.

Lerch, B. A.↗

Elastic/plastic analyses of advanced composites investigating the use of the compliant layer concept in reducing residual stresses resulting from processing

High residual stresses within intermetallic and metal matrix composite systems can develop upon cooling from the processing temperature to room temperature due to the coefficient of thermal expansion (CTE) mismatch between the fiber and matrix. As a result, within certain composite systems, radial, circumferential, and/or longitudinal cracks have been observed to form at the fiber-matrix interface. The compliant layer concept (insertion of a compensating interface material between the fiber and matrix) was proposed to reduce or eliminate the residual stress buildup during cooling and thus minimize cracking. The viability of the proposed compliant layer concept is investigated both elastically and elastoplastically. A detailed parametric study was conducted using a unit cell model consisting of three concentric cylinders to determine the required character (i.e., thickness and material properties) of the compliant layer as well as its applicability. The unknown compliant layer mechanical properties were expressed as ratios of the corresponding temperature dependent Ti-24Al-11Nb (a/o) matrix properties. The fiber properties taken were those corresponding to SCS-6 (SiC). Results indicate that the compliant layer can be used to reduce, if not eliminate, radial and circumferential residual stresses within the fiber and matrix and therefore also reduce or eliminate the radial cracking. However, with this decrease in in-plane stresses, one obtains an increase in longitudinal stress, thus potentially initiating longitudinal cracking. Guidelines are given for the selection of a specific compliant material, given a perfectly bonded system.

Arnold, Steven M.↗

Reduction of Thermal Residual Stresses in Advanced Metallic Composites Based upon a Compensating/Compliant Layer Concept

High residual stresses within metal and intermetallic matrix composite systems can develop upon cooling from the processing temperature to room temperature due to the coefficient of thermal expansion (CTE) mismatch between the fiber and matrix. As a result, within certain composite systems, radial, circumferential, and/or longitudinal cracks have been observed to form at the fiber-matrix interface region. The compliant layer concept (insertion of a compensating interface material between the fiber and matrix) has been proposed to reduce or eliminate the residual stress buildup during cooling, and thus minimize cracking. The present study investigates elastic-plastically the viability of the proposed compliant layer concept. A detailed parametric study was conducted utilizing a unit cell model consisting of three concentric cylinders to determine the required character (i.e., thickness and mechanical properties) of the compliant layer as well as its applicability. The unknown compliant layer mechanical properties were expressed as ratios of the corresponding temperature dependent Ti-24Al-11Nb (a/o) matrix properties. The fiber properties taken were those corresponding to SCS-6 (SiC). Results indicated that the compliant layer can be used to reduce, if not eliminate, radial and circumferential residual stresses within the fiber and matrix and therefore also reduce or eliminate the radial cracking. However, with this decrease in in-plane stresses, one obtains an increase in longitudinal stress, thus potentially initiating longitudinal cracking. Guidelines are given for the selection of a specific compensating/ compliant material, given a perfectly bonded system.

S. M. Arnold↗

Interface considerations in Al2O3/NiAl composite

The fiber-matrix interface requirements in an Al2O3/NiAl composite were examined from theoretical considerations. Several factors that influence the interface bonding requirements were analyzed. These include: (1) residual stresses due to fiber-matrix coefficient of thermal expansion (CTE) mismatch; (2) matrix cracking stress at room temperature; (3) fracture toughness at room temperature; (4) load transfer from the matrix to the fiber and ultimate tensile strength at the use temperature; and (5) creep resistance at high temperature. A relatively weak fiber-matrix bond, with an interfacial shear strength of approximately 15-20 MPa, might be sufficient for attaining the desired mechanical properties in the fiber direction at the use temperature. A weak fiber-matrix bond is also beneficial for increasing the fracture toughness of the composite at room temperature. In contrast, a strong fiber-matrix bond is required to withstand some of the residual stresses resulting from the fiber-matrix CTE mismatch, which are not likely to be reduced significantly by interface coatings. A relatively strong bond is also beneficial in increasing the matrix cracking stress at room temperature. Various interface coating options to accommodate the conflicting bonding requirements were reviewed. One viable coating option is to incorporate a thick, ductile interface layer well bonded to both the fiber and the matrix.

Misra, Ajay K.↗

Isothermal and nonisothermal fatigue behavior of a metal matrix composite

The isothermal and nonisothermal fatigue resistance of a metal matrix composite (MMC) consisting of Ti-15V-3Cr-3Al-3Sn (Ti-15-3) matrix reinforced by 33 vol pct continuous SiC fibers was investigated. The fibers were nominally oriented parallel to the specimen axis. Isothermal fatigue tests were performed in air at 300 and 550 C. The MMC had good isothermal fatigue resistance at low cyclic stress, with fatigue cracks initiating from fiber-matrix interfaces and foil laminations. At high cyclic stresses, stress relaxation in the matrix reduced isothermal composite fatigue resistance at 550 C. Nonisothermal fatigue loading substantially degraded composite fatigue resistnce. This degradation was produced by a thermomechanical fatigue damage mechanism associated with the fiber-matrix interfaces.

Gabb, T. P.↗