Search NASA⌕ Search

SEARCH · Search NASA

Results for “fiber optic strain sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Application of Distributed Fiber Optic Strain Sensors to LMQXFA Cold Mass Welding

The future High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include the low-beta inner triplets (Q1, Q2a/b, Q3) for two LHC insertion regions. The Q1, Q3 components consist of eight 10 m-long LMQXFA cryo-assemblies fabricated by the HL-LHC Accelerator Upgrade Project. Each LMQXFA Cold mass contains two Nb 3 Sn magnets connected in series. A stainless-steel shell is welded around the two magnets before the insertion into the cryostat. There is a limit on how much coil preload increase induced by the shell welding is allowed. Distributed Rayleigh backscattering fiber optics sensors were used for the first time to obtain a strain map over a wide area of a Nb 3 Sn magnet cold mass shell. Finally, data were collected during welding of the first LMQXFA cold mass and the results confirm that the increase of the coil pole azimuthal pre-stress after welding do not exceed requirements.

43 PARTICLE ACCELERATORS↗

Field validation of dynamic mechanical torque measurements using fiber-optic strain sensors for geared wind turbines

Abstract Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory’s Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors’ successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

In situ measurement of phase transformations and residual stress evolution during welding using spatially distributed fiber-optic strain sensors

Welding of high-strength steels can result in large tensile strains as the base metal and filler material cool from their molten state. To combat these large tensile strains, low-transformation-temperature (LTT) metal fillers have been proposed. These fillers undergo a martensitic phase transformation at a lower temperature which can ultimately reduce the tensile strain or can even introduce compressive strain adjacent to the weld metal. However, the process for optimizing the composition of the LTT material, as well as various weld parameters for each unique weld geometry, can be quite expensive, especially if the acceptance criterion requires using neutrons, x-ray beams, or destructive techniques to characterize residual stresses. This work describes a simple, low-cost method for quantifying residual stresses and phase transformations in situ during welding. Spatially distributed fiber-optic sensors were bonded to a cast iron plate, along with tack-welded thermocouples, to measure temperature and strain during multiple passes with LTT filler metals. Results show that the fiber-optic sensors can successfully resolve compressive strain adjacent to the weld region caused by the martensitic phase transformations in the LTT filler material.

47 OTHER INSTRUMENTATION↗

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry↗

Field Validation of Dynamic Mechanical Torque Measurements for Geared Wind Turbines

Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory's Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors' successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

Flow-Assisted Corrosion in Nuclear Power Plants

The flow-assisted corrosion, or flow-accelerated corrosion (FAC) is one of the major piping degradation mechanisms in aging nuclear power plants and it has been identified as a research area under the Light Water Reactor Sustainability program at Idaho National Laboratory (INL). While every nuclear power plant in US has a dedicated flow-assisted corrosion management program, there are several areas where the management of flow assisted corrosion can be improved. One of such areas is on-line corrosion monitoring which can significantly reduce maintenance inspections and contribute to improvement of economic efficiency of nuclear power plants. The proliferation of low cost sensor modalities such as strain fiber optics sensors and noninvasive concentration sensors, allowed development of on-line nonintrusive monitoring techniques, which can complement or replace existing evaluation techniques. The report presents a literature review of the current state-of-the-art in flow-assisted corrosion monitoring, and a research framework to study on-line monitoring techniques. The report addresses the problem on on-line monitoring of flow-assisted corrosion in nuclear power plants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrate embedding of sensors in a relevant microreactor component

This report describes the first successful embedding of sensors in stainless steel pipe specimens and a miniature hex block to support structural health monitoring of microreactor components during electrically heated testing in non-nuclear testbed facilities. Sensors were embedded with an ultrasonic additive manufacturing process that uses a combination of downward pressure and an ultrasonic scrubbing motion to bond stainless steel foils to underlying materials. After placing sensors within cavities that have been machined to the size of the sensors, the ultrasonic bonding process fills the gaps around the sensors and embeds them within the part. Both Type K thermocouples and spatially distributed fiber-optic strain sensors were successfully embedded within two pipe specimens and a miniature hex block. After the fiber-optic sensors were embedded, they were interrogated and found to have minimal signal attenuation within the embedded region—a significant improvement compared to previous trials. This is likely because of the low-bend-loss fiber that was used, which greatly reduces microbending losses that occur after the embedding process. In addition to showing minimal signal attention, the fibers also showed adequate compressive strain, which is a strong indication that the sensors are physically embedded in the parts as opposed to simply being loosely contained inside the machined cavities. The embedded fibers were able to capture the strain induced in one of the pipe specimens while the pipe was actively heated with a moving heat source.

42 ENGINEERING↗

Strain Measurement in the Spallation Target Using High-Radiation-Tolerant Fiber Sensors

We describe the measurement of fast dynamic strains in the mercury target module of the spallation neutron source using customized high-radiation-tolerant fiber-optic strain sensors. The sensors are made from fluorine-doped single-mode optical fibers that demonstrated high radiation tolerance at 1300 nm. A digital phase demodulation scheme is employed in the signal interrogation system, which enables high bandwidth measurement and has an excellent adaptability to sensor output power fluctuations and sensor gap variations. Fast transient strain waveforms induced by high-energy, high-intensity proton pulses are successfully measured. Here, the sensors have survived radiation doses of 10 9 Gy. Both measurement bandwidth and radiation tolerance of the sensors are an order of magnitude higher than their commercial counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EGS Collab Project: Accomplishments and Plan

To better understand stimulation and inter-well flow in crystalline rock with the goal of developing and improving subsurface heat exchangers for enhanced geothermal energy recovery, the EGS (Enhanced Geothermal Systems) Collab project is developing highly monitored, well- characterized intermediate scale (~10-20 m) field test beds, stimulating, and performing flow tests. These tests provide the ability to evaluate concepts, data to test and validate models, and tools to be used for EGS development, which may be evaluated at DOE’s Frontier Observatory for Research in Geothermal Energy (FORGE) project. Numerical simulation is key to the project, for experiment design and interpretation of results. Testbed characterization included optical and acoustic televiewers, full waveform seismic, electromagnetic, gamma, and temperature. The test block was further characterized using seismic tomography (p- and s-), electrical resistance tomography (ERT), and hydrologic characterization including tracer tests. Coupled process models are constrained by the detailed site characterization data. Installed monitoring systems include: 1) passive seismic/acoustic emissions; 2) continuous active source seismic; 3) ERT, with dynamic imaging using high contrast fluids; and 4) distributed acoustic, temperature, and strain fiber optic sensors. During flow and stimulation tests, fracture aperture strain monitoring is performed using the Step-rate Injection Method for Fracture In-situ Properties (SIMFIP) tool. Pressure and flow in the injection and production boreholes are monitored, and tracer tests and wavefield imaging and inversion are performed to provide additional constraints. Stimulations have been performed at several locations, connecting our injection and production wells. An overview of the EGS Collab project is presented to provide a framework for other EGS Collab presentations, along with results from numerical simulations and experiments performed at the Sanford Underground Research Facility in South Dakota.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

Expanding the range of the resolvable strain from distributed fiber optic sensors using a local adaptive reference approach

Optical frequency domain reflectometry (OFDR) is a spectral measurement technique in which shifts in the local Rayleigh backscatter spectra can be used to perform distributed temperature or strain measurements relative to a reference measurement using ordinary single-mode optical fibers. Here, we demonstrate a data processing methodology for improving the resolvable range of temperature and strain by adaptively varying the reference measurement position by position, based on the time evolution of the local optical intensities and the correlation between the reference and active measurements. These methods nearly double the resolvable range of temperature and strain compared with that achieved using the traditional static reference approach.

47 OTHER INSTRUMENTATION↗

High-resolution absolute frequency referenced fiber optic sensor for quasi-static strain sensing

We present a quasi-static fiber optic strain sensing system capable of resolving signals below nanostrain from 20 mHz. A telecom-grade distributed feedback CW diode laser is locked to a fiber Fabry-Perot sensor, transferring the detected signals onto the laser. An H{sup 13}C{sup 14}N absorption line is then used as a frequency reference to extract accurate low-frequency strain signals from the locked system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗