Search NASA⌕ Search

SEARCH · Search NASA

Results for “field performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Silicon Heterojunction Field Performance

The market share of silicon heterojunction (SHJ) modules are expected to increase in the following years. The presentation discusses field performance of SHJ and compares it to other high-efficiency modules. In-depth materials characterization is used to understand the origins of degradation in these type of modules.

ENGINEERING,SOLAR ENERGY↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

Predicting photothermal field performance

Photothermal field performance in flat plate solar collectors was predicted. An analytical model which incorporates the measured dependency between transmittance loss and UV and temperature exposure levels was developed. The model uses SOLMET weather data extrapolated to 30 years for various sites and module mounting configurations. It is concluded that the temperature is the key to photothermally induced transmittance loss. The sensitivity of transmittance loss to UV level is nonlinear with minimum in curve near one sun. The ethylene vinyl acetate (EVA) results are consistent with 30 year life allocation.

Gonzalez, C. C.↗

PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Field performance of a district central ground source heat pump system in the US

This case study discusses the field performance of a district central ground source heat pump (GSHP) system installed at Ball State University (BSU) in Muncie, IN., USA. This district GSHP system replaces the existing central steam plant and water-cooled chiller plants and designed to serve 47 major buildings in BSU. The field performance of the GSHP system was analyzed based on measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. It was compared with the performance of a baseline scenario- a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. This paper presents the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district central GSHP system.

Im, Piljae↗

Correlation of In-Field Performance of Thick REBCO Films Between 0–14 T and 4.2–77 K

We present results on correlation of in-field performance of 2G-high temperature superconductor (HTS) tapes produced by an advanced metal organic chemical vapor deposition (A-MOCVD) system which enables growth of very thick films (>4 μm) without deterioration in performance with thickness. A set of 175 samples has been measured using a vibrating sample magnetometer (VSM), at temperatures ranging from 4.2 to 77 K and field from 0 to 14 T (B⊥tape). The sample set contains a wide range of characteristics, with Zr doping from 0 to 20 mol.%, film thickness from 1 to over 4 μm and a range of compositions with varying rare earth (RE) excess, as well as varying Ba/Cu stoichiometry. The set has been purposely chosen to include a very wide range of properties, with the goal of identifying common features of REBCO conductors that are independent of the listed variables. The in-field critical current density (Jc) performance has been separated into two factors, temperature dependent self-field Jc and field and temperature dependent retention factor. The results reveal very systematic trends in maximum Jc correlation with temperature and field, which can be utilized both for long length characterization and as a tool for providing insight into pinning mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Construction of an embankment with a fly and bottom ash mixture: field performance study

Fly ash and bottom ash are coal combustion by-products (CCBPs) that are generated in large quantities throughout the world. It is often economical to dispose ash as mixtures rather than separately; that notwithstanding, only a few studies have been performed to investigate the behavior of fly and bottom ash mixtures, particularly those with high contents of fly ash. Also, there is very limited data available in the literature on the field performance of structures constructed using ash mixtures. This paper describes the construction and the instrumentation of a demonstration embankment built with an ash mixture (60:40 by weight of fly ash:bottom ash) on State Road 641, Terre Haute, Ind. Monitoring of the demonstration embankment was conducted for a period of 1 year from the start of construction of the embankment. The settlement of the embankment stabilized approximately 5 months after the end of its construction. According to horizontal inclinometer readings, the differential settlement at the top of the embankment is about 5 mm. Results from field quality control tests performed during construction of the demonstration embankment and monitoring data from vertical and horizontal inclinometers and settlement plates indicate that the ash mixture investigated can be considered an acceptable embankment construction material.

01 COAL, LIGNITE, AND PEAT↗

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert↗

Enhanced and Uniform in-Field Performance in Long (Gd,Y)-Ba-Cu-O Tapes with Zirconium Doping Fabricated by Metal Organic Chemical Vapor Deposition

The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I{sub c}) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 {mu}m thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I{sub c} in the orientation of field parallel to the c-axis and retain 28% of their self-field I{sub c} value at 77 K and 1 T. BaZrO{sub 3} (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of {beta} {parallel} c-axis. A retention factor of 36% of the zero-field I{sub c} value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

36 MATERIALS SCIENCE↗

Ta, Ti and Hf effects on Nb 3 Sn high-field performance: temperature-dependent dopant occupancy and failure of Kramer extrapolation

The increasing demand for improving the high-field (16-22 T) performance of Nb 3 Sn conductors requires a better understanding of the properties of modern wires much closer to irreversibility field, H Irr . In this study we investigated the impact of Ta, Ti and Hf doping on the high-field pinning properties, the upper critical field, H c2 , and H Irr . We found that the pinning force curves of commercial Ti and Ta doped wires at different temperatures do not scale and that the Kramer extrapolation, typically used by magnet designers to estimate high-field critical current density and magnet operational margins from lower field data, is not reliable and significantly overestimates the actual H Irr . In contrast, new laboratory scale conductors made with Nb-Ta-Hf alloy have improved high-field J c performance and, despite contributions by both grain boundary and point defect pinning mechanisms, have more predictable high-field behavior. Using Extended X-ray Absorption Fine Structure spectroscopy, EXAFS, we found that for the commercial Ta and Ti doped conductors, the Ta site occupancy in the A15 structure gradually changes with the heat treatment temperature whereas Ti is always located on the Nb site with clear consequences for H c2 . Finally, this work reveals the still limited understanding of what determines H c2 , H Irr and the high-field J c performance of Nb 3 Sn and the complexity of optimizing these conductors so that they can reach their full potential for high-field applications.

36 MATERIALS SCIENCE↗

In-Field Performance of Biomass Balers

Herbaceous biomass will contribute significantly to meeting renewable energy goals. Harvesting equipment for hay is generally suitable for mowing, raking, and baling grasses such as switchgrass; however, there is a need for field data to better understand machine performance in energy crops. The purpose of this study was to collect field data to estimate baler field capacity, throughput, and speed. Data gathered with a Differential Global Positioning System (DGPS) unit during baling provided time-motion studies of baler productivity. Six fields were used to compare field capacity, speed, and throughput results from four round balers and one large-square baler. The results show that in-field performance of round balers is significantly affected by yield, but that the relationship can be represented with machinery management concepts, knowledge of maximum throughput, and wrap-eject time. Baler performance will be overestimated if the yield, maximum throughput, and wrap-eject time are not correctly accounted for.

Grisso, Robert “Bobby” (ORCID:0000000267893558)↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. A 1,180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row were calculated and recorded along with sensor, insolation, and weather data every five minutes using a minicomputer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Long-Term Evaluation of SSL Field Performance in Select Interior Projects

This GATEWAY project evaluated four field installations to better understand the long-term performance of a number of LED products, which can hopefully stimulate improvements in designing, manufacturing, specifying, procuring, and installing LED products. Field studies provide the opportunity to discover and investigate issues that cannot be simulated or uncovered in a laboratory, but the installed performance over time of commercially available LED products has not been well documented. Improving long-term performance can provide both direct energy savings by reducing the need to over-light to account for light loss and indirect energy savings through better market penetration due to SSL’s competitive advantages over less-efficient light source technologies. The projects evaluated for this report illustrate that SSL use is often motivated by advantages other than energy savings, including maintenance savings, easier integration with control systems, and improved lighting quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of storage field performance to geologic and cavern design parameters in salt domes.

A sensitivity study was performed utilizing a three dimensional finite element model to assess allowable cavern field sizes for strategic petroleum reserve salt domes. A potential exists for tensile fracturing and dilatancy damage to salt that can compromise the integrity of a cavern field in situations where high extraction ratios exist. The effects of salt creep rate, depth of salt dome top, dome size, caprock thickness, elastic moduli of caprock and surrounding rock, lateral stress ratio of surrounding rock, cavern size, depth of cavern, and number of caverns are examined numerically. As a result, a correlation table between the parameters and the impact on the performance of storage field was established. In general, slower salt creep rates, deeper depth of salt dome top, larger elastic moduli of caprock and surrounding rock, and a smaller radius of cavern are better for structural performance of the salt dome.

02 PETROLEUM↗

Sensitivity of storage field performance to geologic and cavern design parameters in salt domes.

A sensitivity study was performed utilizing a three dimensional finite element model to assess allowable cavern field sizes in strategic petroleum reserve salt domes. A potential exists for tensile fracturing and dilatancy damage to salt that can compromise the integrity of a cavern field in situations where high extraction ratios exist. The effects of salt creep rate, depth of salt dome top, dome size, caprock thickness, elastic moduli of caprock and surrounding rock, lateral stress ratio of surrounding rock, cavern size, depth of cavern, and number of caverns are examined numerically. As a result, a correlation table between the parameters and the impact on the performance of a storage field was established. In general, slower salt creep rates, deeper depth of salt dome top, larger elastic moduli of caprock and surrounding rock, and a smaller radius of cavern are better for structural performance of the salt dome.

02 PETROLEUM↗