At least 19 records

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Field Study: Influence of Key Measures in Home Rules States

The goal of the Energy Efficiency Field Study: Influence of Key Measures in Home Rule States project is to empower and support the states of Utah and Arizona in the successful implementation of their building energy codes. Employing the Department of Energy (DOE) Residential Building Energy Code Field Study Data Collection & Methodology, the research team evaluated real-world implementation status against a baseline, with a particular focus on the unique challenges presented by the dry, hot climates of Utah and Arizona.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Energy Code Field Study: Data Collection Methodology and Protocol

In support of the U.S. Department of Energy’s Commercial Buildings Energy Code Field Study, this data collection methodology and protocol provides guidance on all aspects of undertaking a compliance study, from development of a sampling plan to recruitment to code requirements and compliance checks for each energy code measure specified to be collected. The protocol also includes a data collection form that captures all key information needed for analysis of commercial energy code compliance. This methodology was developed by the Institute for Market Transformation in coordination with Pacific Northwest National Laboratory (PNNL) and the U.S. Department of Energy Building Energy Codes Program with the objective of assisting states, jurisdictions, utilities and others as they seek to measure and demonstrate compliance rates with energy codes in commercial buildings, as well as to target areas for improvement through increased energy code compliance and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set representing baseline construction practices across the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Differing behavioral changes in crayfish and bluegill under short- and long-chain PFAS exposures: Field study in Northern Michigan, USA

The emergent contaminant family, per- and poly-fluorinated alkyl substances (PFAS) has gained research attention due to their widespread detection and stability within the environment. Despite the growing amount of research on perfluorooctanesulfonic acid (PFOS) and perfluoro-n-octanoic acid (PFOA) in aquatic organisms, investigations detailing behavioral and physiological effects of aquatic organisms exposed to a mixture of PFAS analytes in the wild have been limited. The objective of this study was to evaluate the potential behavioral and histological effects of environmental exposure to PFAS compounds within multiple trophic levels of aquatic ecosystems. The current study investigates effects of environmentally relevant PFAS concentration exposures in crayfish (Faxonius immunis, F. rusticus, F. virilis) and bluegill (Lepomis macrochirus) sourced from four water bodies in Northern Michigan. Antipredator response and foraging behavioral assays were used to investigate potential effects on crayfish; a swimming speed behavioral assay and liver and gill histology analysis were used to investigate potential effects on fish. Linear mixed model and multiple regression analyses resulted in significant relationships between tissue accumulation levels of long chain PFAS compounds and crayfish foraging and fish critical swimming speed responses. Crayfish foraging decreased and fish critical swim speeds increased with PFAS exposure which may lead to energetic and population concerns. Antipredator response in crayfish and liver and gill histology in fish were not significantly related to PFAS tissue or water concentrations. The sensitivity of crayfish and bluegill behavior contributes to the growing body of research regarding the differential toxicity of short-chain and long-chain PFAS compounds. The sensitivity of some aquatic organism behaviors to PFAS accumulated in tissue may have implications for PFAS transfer and alterations to ecosystem functioning; based on the results of this field study, further laboratory research is recommended to further evaluate these relationships.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES↗

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Techno-economic assessment of distributed wellhead RO water treatment for nitrate removal and salinity reduction: A field study in small disadvantaged communities

Techno-economic analysis of distributed wellhead water treatment and desalination (DWTD) systems was carried out based on a three-year field study in three small, disadvantaged communities (DACs) to evaluate the reliability and affordability of upgrading their impaired well water. The local water supplies of the three study DACs, located in Salinas Valley, California, were contaminated with nitrate at levels (~ 12–87 mg/L NO$^{-}_{3}$ - N) ) above the California maximum contaminant level (MCL) of 10 mg/L NO$^{-}_{3}$ - N , and had elevated water salinity (~600–1,600 mg/L total dissolved solids(TDS)) above its secondary MCL (SMCL) of 500 mg/L TDS. Well water nitrate removal and salinity reduction were accomplished via reverse osmosis (RO) based DWTD systems that operated autonomously, supported by remote monitoring and supervisory cyberinfrastructure. Reliable DWTD operation provided treated water quality, with respect to nitrate and salinity, in the range of 0.5–6.3 mg/L NO$^{-}_{3}$ - N and 57–161 mg/L TDS, respectively, which were well below the respective MCL and SMCL. The levelized cost of water treatment was in the range of ~$$2/m 3 - $$2.9/m 3 which aligns with typical residential water costs in California and in the study region, and monthly residential water costs (39 dollars-74 dollars/residential unit/month) were also within the range in California. The study showcased the DWTD approach as a viable and potentially scalable solution for upgrading impaired local potable water supply of communities lacking centralized water delivery infrastructure. However, streamlined permitting processes and standardized regulatory frameworks are critical to promoting wider adoption and maximizing the socio-economic benefits of the DWT approach. Moreover, DACs are likely to require government subsidies in order to cover the CapEx of DWTD systems in addition to upgrade of site infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grain boundary effects in high-temperature liquid-metal dealloying: a multi-phase field study

Abstract A multi-phase field model is employed to study the microstructural evolution of an alloy undergoing liquid dealloying, specifically considering the role of grain boundaries. A semi-implicit time-stepping algorithm using spectral methods is implemented, which enables simulating large 2D and 3D domains over long time scales while still maintaining a realistic interfacial thickness. Simulations reveal a mechanism of coupled grain–boundary migration to maintain equilibrium contact angles with the topologically complex solid–liquid interface, which locally accelerates diffusion-coupled growth of a liquid channel into the precursor. This mechanism asymmetrically disrupts the ligament connectivity of the dealloyed structure in qualitative agreement with published experimental observations. The grain boundary migration-assisted corrosion channels form even for precursors with small amounts of the dissolving alloy species, below the parting limit . The activation of this grain boundary dealloying mechanism depends strongly on grain boundary mobility.

36 MATERIALS SCIENCE↗

Modular Multi-family Construction: A Field Study of Energy Code Compliance and Performance through Offsite Prefabrication

Prefabrication in a controlled, factory setting may improve the energy code compliance and energy performance of modular buildings compared to traditional site-built buildings. To test this premise, the work detailed in this DOE-funded commercial field study (EE0009082) compares the energy code compliance of 25 modular and 30 site-built multifamily buildings under construction in Los Angeles, San Francisco, Philadelphia and Seattle representing climate zones 3B, 3C, 4A and 4C respectively. This dataset includes full data on 20 modular and site-built buildings and partial data on 35 modular and site-built buildings that had started prior to or were completed after the 18-month data collection period. This study also compares the post-occupancy energy performance or energy use intensity (EUI) of an additional 23 modular multifamily buildings and 128 site-built multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗