Can disposable masks be worn more than once?

Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks. The FFEs of masks were compared following extended wearing with and without washing. Results reveal that most disposable facemasks can retain a high level of their baseline FFE after extended wearing, even after 40 h of wearing. Laundering disposable masks degraded FFE in some instances. We conclude that the durability of disposable facemask performance is considerably longer than their intended single use indication, suggesting that reusing disposable masks is a safe means of reducing plastic waste in the environment.

54 ENVIRONMENTAL SCIENCES↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

A scalable method of applying heat and humidity for decontamination of N95 respirators during the COVID-19 crisis

A lack of N95 Filtering Facepiece Respirators (FFRs) during the COVID-19 crisis has placed healthcare workers at risk. It is important for any N95 reuse strategy to determine the effects that proposed protocols would have on the physical functioning of the mask, as well as the practical aspects of implementation. Here we propose and implement a method of heating N95 respirators with moisture (85°C, 60-85% humidity). We test both mask filtration efficiency and fit to validate this process. Our tests focus on the 3M 1860, 3M 1870, and 3M 8210 Plus N95 models. After five cycles of the heating procedure, all three respirators pass both quantitative fit testing (score of >100) and show no degradation of mask filtration efficiency. We also test the Chen Heng V9501 KN95 and HKYQ N95 finding no degradation of mask filtration efficiency, however even for unheated masks these scored <50 for every fit test. The heating method presented here is scalable from individual masks to over a thousand a day with a single industrial convection oven, making this method practical for local application inside health-care facilities.

59 BASIC BIOLOGICAL SCIENCES↗

Filtration Performance of Layering Masks and Face Coverings and the Reusability of Cotton Masks after Repeated Washing and Drying

In this study, filtration efficiency of different respirators, face masks, and a 2-ply cotton handkerchief bandana was compared for particles in the size range of 60 nm-4 um under a "perfect fit" condition. The filtration efficiency at the most penetrating particle size of 0.3 um on average ranged from 83-99% for N95 and KN95 respirators, 42-88% for surgical masks, 16-23% for cloth masks, and 9% for bandana. We also investigated the effects of using double surgical masks or layering a cloth mask over various surgical masks in terms of their filtration characteristics. In most of these combinations, the filtration efficiency improved by ~25% for particles 0.3-1 um in diameter without any substantial change in the filter quality factor when compared to the highest of the individual mask results. To investigate the reusability of cotton cloth masks, 2-layer cotton fabric sample coupons were machine washed and dried for 52 cycles leading to an increase in inhalation resistance (~20 Pa) without affecting size-resolved filtration efficiency. Scanning electron microscopy revealed that washing and drying led to the gradual deconstruction of cotton fibers at the scale of several micrometers to hundreds of nanometers in the form of delamination of the fiber wall and fibrillation of the nanofiber constituents. Results indicate that cloth masks may be layered over surgical masks for additional benefits, and that cloth masks made out of cotton fabric can be washed and reused numerous times without a significant loss in filtration efficiency.

99 GENERAL AND MISCELLANEOUS↗

Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks

The emergence of a pandemic affecting the respiratory system can result in a significant demand for face masks. This includes the use of cloth masks by large sections of the public, as can be seen during the current global spread of COVID-19. However, there is limited knowledge available on the performance of various commonly available fabrics used in cloth masks. Importantly, there is a need to evaluate filtration efficiencies as a function of aerosol particulate sizes in the 10 nm – 10 µm range, which is particularly relevant for respiratory virus transmission. We have carried out these studies for several common fabrics including cotton, silk, chiffon, flannel, various synthetics, and their combinations. While the filtration efficiencies for various fabrics when a single layer was used ranged from 5-80% and 15-95% for particle sizes <300 nm and >300 nm respectively, the efficiencies improved when multiple layers were used, and when using a specific combination of different fabrics. Filtration efficiencies of the hybrids (such as cotton-silk, cotton-chiffon, cotton-flannel) was >80 % (for particles <300 nm) and >90 % (for particles >300 nm). We speculate that the enhanced performance of the hybrids is likely due to the combined effect of mechanical and electrostatic-based filtration. Cotton, the most widely used material for cloth masks performs better at higher weave densities (i.e., threads per inch) and can make a significant difference in filtration efficiencies. Our studies also imply that gaps (as caused by an improper fit of the mask) can result in over a 60% decrease in the filtration efficiency, implying the need for future cloth mask design studies to take into account issues of “fit” and leakage, while allowing the exhaled air to vent efficiently. Overall, we find that combinations of various commonly available fabrics used in cloth masks can potentially provide significant protection against the transmission of aerosol particles.

36 MATERIALS SCIENCE↗

Quantitative Fit Evaluation of N95 Filtering Facepiece Respirators and Coronavirus Inactivation Following Heat Treatment

Abstract Reuse of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use has become common in healthcare facilities due to shortages caused by the COVID-19 pandemic. Here, we report that murine hepatitis coronavirus initially seeded on FFR filter material is inactivated (6 order of magnitude reduction as measured by median tissue culture infective dose, TCID50) after dry heating at 75°C for 30 min. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or 10 heating cycles. Previous studies have reported that the filtration efficiency of FFRs is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to reuse N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also observe that a radiative heat source (e.g. an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investigating heat as a means to recycle FFRs. These differences suggest that while our repeated decontamination cycles do not affect FFR fit, overall wear time and the number of donning/doffing cycles are important factors that likely degrade FFR fit and must be investigated further.

60 APPLIED LIFE SCIENCES↗

Quantitative form and fit of N95 filtering facepiece respirators are retained after dry and humid heat treatments for coronavirus deactivation

Re-use of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use only is becoming common in healthcare facilities due to shortages caused by the COVID19 pandemic. Here we report that mouse hepatitis virus (MHV) initially seeded on FFR filter material is inactivated (6 log reduction as measured by 50% tissue culture infective dose (TCID50)) after dry heating at 75 °C for 30 minutes. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or ten heating cycles. Previous studies have reported that the filtration efficiency of FFR filters is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to re-use N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also found that a heat source that emits radiation (e.g., an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investing heat as a means to recycle FFRs and suggest that overall wear time and donning/doffing cycles are important factors that need to be considered.

36 MATERIALS SCIENCE↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Performance and electret charge of N95 respirators after decontamination [Slides]

Filtration, pressure drop and quantitative fit of N95 respirators were robust to several decontamination methods including vaporous hydrogen peroxide, wet heat, bleach, and ultraviolet light. Bleach may not have penetrated the hydrophobic outer layers of the N95 respirator. Isopropyl alcohol and detergent both severely degraded the electrostatic charge of the electret filtration layer. First data in N95 respirators that the loss of filtration efficiency was directly correlated with loss of surface potential on the filtration layer. The pressure drop was unchanged, so loss of filtration efficacy would not be apparent during a user seal check. Mechanical straps degrade with repeated mechanical cycling during extended use. Decontamination did not appear to degrade the elastic straps. Significant loss of strap elasticity would be apparent during a user negative pressure seal check.

36 MATERIALS SCIENCE↗

Linking the Dynamic Response of the Carbon Dioxide-Concentrating Mechanism to Carbon Assimilation Behavior in Fremyella diplosiphon

ABSTRACT Cyanobacteria use a carbon dioxide (CO 2 )-concentrating mechanism (CCM) that enhances their carbon fixation efficiency and is regulated by many environmental factors that impact photosynthesis, including carbon availability, light levels, and nutrient access. Efforts to connect the regulation of the CCM by these factors to functional effects on carbon assimilation rates have been complicated by the aqueous nature of cyanobacteria. Here, we describe the use of cyanobacteria in a semiwet state on glass fiber filtration discs—cyanobacterial discs—to establish dynamic carbon assimilation behavior using gas exchange analysis. In combination with quantitative PCR (qPCR) and transmission electron microscopy (TEM) analyses, we linked the regulation of CCM components to corresponding carbon assimilation behavior in the freshwater, filamentous cyanobacterium Fremyella diplosiphon . Inorganic carbon (C i ) levels, light quantity, and light quality have all been shown to influence carbon assimilation behavior in F. diplosiphon . Our results suggest a biphasic model of cyanobacterial carbon fixation. While behavior at low levels of CO 2 is driven mainly by the C i uptake ability of the cyanobacterium, at higher CO 2 levels, carbon assimilation behavior is multifaceted and depends on C i availability, carboxysome morphology, linear electron flow, and cell shape. Carbon response curves (CRCs) generated via gas exchange analysis enable rapid examination of CO 2 assimilation behavior in cyanobacteria and can be used for cells grown under distinct conditions to provide insight into how CO 2 assimilation correlates with the regulation of critical cellular functions, such as the environmental control of the CCM and downstream photosynthetic capacity. IMPORTANCE Environmental regulation of photosynthesis in cyanobacteria enhances organismal fitness, light capture, and associated carbon fixation under dynamic conditions. Concentration of carbon dioxide (CO 2 ) near the carbon-fixing enzyme RubisCO occurs via the CO 2 -concentrating mechanism (CCM). The CCM is also tuned in response to carbon availability, light quality or levels, or nutrient access—cues that also impact photosynthesis. We adapted dynamic gas exchange methods generally used with plants to investigate environmental regulation of the CCM and carbon fixation capacity using glass fiber-filtered cells of the cyanobacterium Fremyella diplosiphon . We describe a breakthrough in measuring real-time carbon uptake and associated assimilation capacity for cells grown in distinct conditions (i.e., light quality, light quantity, or carbon status). These measurements demonstrate that the CCM modulates carbon uptake and assimilation under low-C i conditions and that light-dependent regulation of pigmentation, cell shape, and downstream stages of carbon fixation are critical for tuning carbon uptake and assimilation.