Search NASA⌕ Search

SEARCH · Search NASA

Results for “fixed targets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

All polymer microfluidic chips—A fixed target sample delivery workhorse for serial crystallography

The development of x-ray free electron laser (XFEL) light sources and serial crystallography methodologies has led to a revolution in protein crystallography, enabling the determination of previously unobtainable protein structures and near-atomic resolution of otherwise poorly diffracting protein crystals. However, to utilize XFEL sources efficiently demands the continuous, rapid delivery of a large number of difficult-to-handle microcrystals to the x-ray beam. A recently developed fixed-target system, in which crystals of interest are enclosed within a sample holder, which is rastered through the x-ray beam, is discussed in detail in this Perspective. The fixed target is easy to use, maintains sample hydration, and can be readily modified to allow a broad range of sample types and different beamline requirements. Recent innovations demonstrate the potential of such microfluidic-based fixed targets to be an all-around “workhorse” for serial crystallography measurements. In conclusion, this Perspective will summarize recent advancements in microfluidic fixed targets for serial crystallography, examine needs for future development, and guide users in designing, choosing, and utilizing a fixed-target sample delivery device for their system.

59 BASIC BIOLOGICAL SCIENCES↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗

Head perturbations during walking while viewing a head-fixed target

Inexpensive, head-fixed computer displays are now available that subjects can wear during locomotion. Our hypothesis is that viewing a head-fixed visual display will change the character- istics of rotational head perturbations during natural walking. Using a 3-axis angular rate sensor, we measured head rotations during natural or treadmill walking, in 10 normal subjects and 2 patients with deficient vestibular function, as they attempted to view (1) a stationary target at optical infinity; and (2) a target at a distance of 20 cm rigidly attached to the head. Normal subjects and patients showed no significant change in the predominant frequency of head rotations in any plane (ranging 0.7-5.7 Hz) during the two different viewing tasks. Mean peak head velocities also showed no difference during the two viewing conditions except in the yaw plane, in which values were greater while viewing the near target. Predominant frequencies of head rotations were similar in the pitch plane during natural or treadmill walking; however, peak velocities of pitch head rotations were substantially greater during natural walking. One vestibular patient showed modest increases of head velocity during natural walking compared with normal subjects. Rotational head perturbations that occur during natural walking are largely unaffected when subjects view a head-fixed target. There is need to study how such perturbations, which induce vestibular eye movements, affect vision of head-fixed displays.

Das, Vallabh E.↗

Contribution from intrinsic charm production to fixed-target interactions with the SMOG Device at LHCb

Intrinsic charm, nonperturbative charm in the hadron wavefunction, has long been speculated but has never been satisfactorily proven. Open charm and 𝐽/𝜓 measurements in a fixed-target configuration at the LHCb searched for this contribution but reported no evidence. $\overline{D}$ meson and 𝐽/𝜓 production is calculated for the SMOG fixed-target configuration in the LHCb experiment using a combination of perturbative QCD and intrinsic charm to see whether intrinsic charm would indeed be observable in the SMOG kinematics. Open charm and 𝐽/𝜓 production is calculated to next-to-leading order in perturbative QCD. Because a gas jet nuclear target is used, cold nuclear matter effects are included in the perturbative calculations. The intrinsic charm is calculated assuming production from a |𝑢⁢𝑢⁢𝑑⁢$\overline{c}$⁢$\rangle$ Fock state. The differential rapidity and transverse momentum distributions in 𝑝+Ne, 𝑝+He, and 𝑝+Ar fixed-target interactions are calculated in the SMOG acceptance and compared to data. The predicted asymmetries between $\overline{D}$ (leading charm) and 𝐷 (nonleading charm) are also shown. The contribution from intrinsic charm is small and decreases with center-of-mass energy. The calculations agree well with the current SMOG data, with or without intrinsic charm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

A fixed-target programme at the LHC: Physics case and projected performances for heavy-ion, hadron, spin and astroparticle studies

Here we review the context, the motivations and the expected performances of a comprehensive and ambitious fixed-target programme using the multi-TeV proton and ion LHC beams. We also provide a detailed account of the different possible technical implementations ranging from an internal wire target to a full dedicated beam line extracted with a bent crystal. The possibilities offered by the use of the ALICE and LHCb detectors in the fixed-target mode are also reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomic binding corrections for high-energy fixed target experiments

High-energy beams incident on a fixed target may scatter against atomic electrons. To a first approximation, one can treat these electrons as free and at rest. For precision experiments, however, it is important to be able to estimate the size of, and when necessary calculate, subleading corrections. We discuss atomic binding corrections to relativistic lepton-electron scattering. We analyze hydrogen in detail, before generalizing our analysis to multi-electron atoms. Using the virial theorem, and many-body sum rules, we find that the corrections can be reduced to measured binding energies, and the expectation value of a single one-body operator. We comment on the phenomenological impact for neutrino flux normalization and an extraction of hadronic vacuum polarization from elastic muon electron scattering at MUonE.

74 ATOMIC AND MOLECULAR PHYSICS↗

Anisotropic Flow in Fixed-Target 208 Pb + 20 Ne Collisions as a Probe of Quark-Gluon Plasma

The System for Measuring Overlap with Gas (SMOG2) at the LHCb detector enables the study of fixed-target ion-ion collisions at relativistic energies ($\sqrt{𝑠_{NN}}$ ∼ 100 GeV in the center of mass). Here, with input from ab initio calculations of the structure of 16 O and 20 Ne , we compute 3+1⁢D hydrodynamic predictions for the anisotropic flow of Pb+Ne and Pb+O collisions to be tested with upcoming LHCb data. This will allow the detailed study of quark-gluon plasma formation as well as experimental tests of the predicted nuclear shapes. Elliptic flow (𝑣 2 ) in Pb + Ne collisions is greatly enhanced compared to the Pb + O baseline due to the shape of 20 Ne , which is deformed in a bowling-pin geometry. Owing to the large 208 Pb radius, this effect is seen in a broad centrality range, a unique feature of this collision configuration. Larger elliptic flow further enhances the quadrangular flow (𝑣 4 ) of Pb + Ne collisions via nonlinear coupling, and impacts the sign of the kurtosis of the elliptic flow vector distribution (𝑐 2 ⁡{4}). Exploiting the shape of 20 Ne proves thus an ideal method to investigate the formation of quark-gluon plasma in fixed-target experiments at LHCb, and demonstrates the power of System for Measuring Overlap with Gas as a tool to image nuclear ground states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic charm production of doubly charmed baryons: Collider vs. fixed-target

We report the LHCb Collaboration has measured the doubly charmed baryon, $\Xi^{++}_{cc} (ucc)$, through two different decay channels in $p + p$ collisions at center-of-mass energies of 7, 8 and 13 TeV. While they have performed similar searches for the doubly charmed baryon $\Xi^{+}_{cc} (dcc)$, it has not yet been observed by LHCb. However, the fixed-target experiment, SELEX, at Fermilab, reported the observation of the $\Xi^{+}_{cc}$ in two different decay channels with a 600 GeV charged hyperon beam. The beam was composed of an admixture of $π^{±}, p, \overline p $ components as well as the $Σ^–$ hyperon. Much discussion has arisen over the fact that the fixed-target observations have not been easily reproduced by the collider experiments at higher energies, where one might have expected the production rates to be much higher due to the orders of magnitude increase in the center of mass energy with LHCb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fixed-target serial femtosecond crystallography using in cellulo grown microcrystals

The crystallization of recombinant proteins in living cells is an exciting new approach in structural biology. Recent success has highlighted the need for fast and efficient diffraction data collection, optimally directly exposing intact crystal-containing cells to the X-ray beam, thus protecting the in cellulo crystals from environmental challenges. Serial femtosecond crystallography (SFX) at free-electron lasers (XFELs) allows the collection of detectable diffraction even from tiny protein crystals, but requires very fast sample exchange to utilize each XFEL pulse. Here, an efficient approach is presented for high-resolution structure elucidation using serial femtosecond in cellulo diffraction of micometre-sized crystals of the protein HEX-1 from the fungus Neurospora crassa on a fixed target. Employing the fast and highly accurate Roadrunner II translation-stage system allowed efficient raster scanning of the pores of micro-patterned, single-crystalline silicon chips loaded with living, crystal-containing insect cells. Compared with liquid-jet and LCP injection systems, the increased hit rates of up to 30% and reduced background scattering enabled elucidation of the HEX-1 structure. Using diffraction data from only a single chip collected within 12 min at the Linac Coherent Light Source, a 1.8 Å resolution structure was obtained with significantly reduced sample consumption compared with previous SFX experiments using liquid-jet injection. This HEX-1 structure is almost superimposable with that previously determined using synchrotron radiation from single HEX-1 crystals grown by sitting-drop vapour diffusion, validating the approach. This study demonstrates that fixed-target SFX using micro-patterned silicon chips is ideally suited for efficient in cellulo diffraction data collection using living, crystal-containing cells, and offers huge potential for the straightforward structure elucidation of proteins that form intracellular crystals at both XFELs and synchrotron sources.

Lahey-Rudolph, J. Mia (ORCID:0000000152797267)↗

Fixed-target serial crystallography at the Structural Biology Center

Serial synchrotron crystallography enables the study of protein structures under physiological temperature and reduced radiation damage by collection of data from thousands of crystals. The Structural Biology Center at Sector 19 of the Advanced Photon Source has implemented a fixed-target approach with a new 3D-printed mesh-holder optimized for sample handling. The holder immobilizes a crystal suspension or droplet emulsion on a nylon mesh, trapping and sealing a near-monolayer of crystals in its mother liquor between two thin Mylar films. Data can be rapidly collected in scan mode and analyzed in near real-time using piezoelectric linear stages assembled in an XYZ arrangement, controlled with a graphical user interface and analyzed using a high-performance computing pipeline. Here, the system was applied to two β-lactamases: a class D serine β-lactamase from Chitinophaga pinensis DSM 2588 and L1 metallo-β-lactamase from Stenotrophomonas maltophilia K279a.

59 BASIC BIOLOGICAL SCIENCES↗

A user-friendly plug-and-play cyclic olefin copolymer-based microfluidic chip for room-temperature, fixed-target serial crystallography

Over the past two decades, serial X-ray crystallography has enabled the structure determination of a wide range of proteins. With the advent of X-ray free-electron lasers (XFELs), ever-smaller crystals have yielded high-resolution diffraction and structure determination. A crucial need to continue advancement is the efficient delivery of fragile and micrometre-sized crystals to the X-ray beam intersection. This paper presents an improved design of an all-polymer microfluidic `chip' for room-temperature fixed-target serial crystallography that can be tailored to broadly meet the needs of users at either synchrotron or XFEL light sources. The chips are designed to be customized around different types of crystals and offer users a friendly, quick, convenient, ultra-low-cost and robust sample-delivery platform. Compared with the previous iteration of the chip [Gilbile et al. (2021), Lab Chip , 21 , 4831–4845], the new design eliminates cleanroom fabrication. It has a larger imaging area to volume, while maintaining crystal hydration stability for both in situ crystallization or direct crystal slurry loading. Crystals of two model proteins, lysozyme and thaumatin, were used to validate the effectiveness of the design at both synchrotron (lysozyme and thaumatin) and XFEL (lysozyme only) facilities, yielding complete data sets with resolutions of 1.42, 1.48 and 1.70 Å, respectively. Overall, the improved chip design, ease of fabrication and high modifiability create a powerful, all-around sample-delivery tool that structural biologists can quickly adopt, especially in cases of limited sample volume and small, fragile crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fixed Target Serial Data Collection at Diamond Light Source

Serial data collection is a relatively new technique for synchrotron users. A user manual for fixed target data collection at I24, Diamond Light Source is presented with detailed step-by-step instructions, figures, and videos for smooth data collection.

Horrell, Sam↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗