FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impedance Based Fixture Neutralization (FINE) Method to Replicate Field Environments in Laboratory Settings

Test article vibration test responses will vary from one test laboratory to another due to differences in shaker and fixture dynamic characteristics. This is also seen between the field and laboratory due to the differing dynamic characteristics between field assembly loading and boundary conditions compared to the laboratory configuration. This work introduces a technique called Impedance Fixture Neutralization which customizes input forces to cause consistent responses for the Device Under Test across different vibration testing conditions. The customized force neutralizes the dynamic variations between configurations for the Device Under Test. The device responses can be replicated in several situations: when using a different fixture with the same attachment points, when the test article mounting location on the fixture changes, when the force location changes, or any combination of these situations. Impedance Fixture Neutralization uses the uncoupled dynamic characteristics of the test article and excitation fixtures to customize the input thereby causing the same test article responses between two mounting configurations (either field to laboratory or two different laboratory configurations). The application of the technique is shown using an analytical model of a two-beam system and analytically using experimental FRFs from plate and frame component hardware characterization tests. In both cases a device under test is attached to two test fixtures wherein the dynamic differences in the configurations are neutralized.

Laboratory↗

Characterization of the Fast-Neutron Irradiator and the Fast-Flux Tube Irradiation Fixtures at the Pennsylvania State Breazeale Reactor

Accurate knowledge of the neutron spectrum at a nuclear research reactor is a prerequisite for planning irradiation experiments, as well as for evaluating irradiation exposure results. The neutron-flux spectrum in the fast-neutron irradiator (FNI) and the fast-flux tube (FFT) irradiation fixtures at the Pennsylvania State Breazeale Reactor (PSBR) were characterized using the multi-foil neutron activation method. These irradiation fixtures make use of graded shielding to produce unique neutron fields. Multiple foil sets were irradiated in the fixtures with different exposure times and reactor powers to understand the stability over a wide range of operating conditions. Measured results were evaluated against a MCNP6 simulation to produce a measurement-informed neutron flux-energy spectrum for each fixture using STAYSL_PNNL. Simulated estimates of the FNI fixture, a newer fixture (~25 years old), demonstrated excellent agreement with measured results; the FFT did not. Thermal neutron measurements from the FFT suggest there is additional thermal leakage not captured in the simulation model. In conclusion, possible explanations for the discrepancy include burn-out or degradation (i.e., micro-cracking, gaps, etc.) in the boral and cadmium liners over the lifetime of the fixture (~40 years old).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model 9975 O Ring Fixture Long-Term Leak Performance (FY2024 Status Report)

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months of testing while fixture #18 remained leak tight. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F.

42 ENGINEERING↗

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam↗

Particle Physics Division Lifting Fixtures Database Restructure

In this project, a thorough investigation is conducted to determine the current placements of all lifting fixtures within the Particle Physics Division (PPD) buildings - as well as whether which ones are still operable. Briefly, the reasoning as to why these lifting fixtures must be found and the database must be updated is covered in the beginning sections of the report. Many tools and fixtures get moved around and forgotten about, and Fermilab’s systems have been updated more than a few times throughout the years, so data can get lost and forgotten about. Considering that many of these lifting fixtures have not been used in years or there is missing, impertinent information that is required by Fermilab’s modern standards and safety regulations. Lifting fixtures found at each site are measured, photographed, and logged; later analyzed to determine if they are under PPD’s purview or another department so that the respective authorities can be notified. Once maximum information is found for all the fixtures they are formatted to 2025 Fermilab standards in an easily accessible digital list for PPD employees.

Creedon, Carroll [Unlisted, US, IL]↗

Pressure effects on lithium anode/nickel-manganese-cobalt oxide cathode pouch cells through fixture design

Applying external pressure to a pouch cell results in improved performance, implicating systems-level design of batteries. Here, different formats and amounts of external pressure to Li-Li x Ni 0.8 Mn 0.1 Co 0.1 O 2 (Li-NMC811) pouch cells were studied under lean electrolyte conditions. Due to the more uniform lithium plating/stripping, a constant gap fixture that retains the distance of the frame during cycling performed greater than a constant pressure fixture that retains applied pressure to the cell. In addition, the use of flexible foam in a constant gap fixture revealed enhanced cycle life at 10 psi; however, at 30 psi, the use of a rigid plate extended cycle life to over 250 cycles, while the foam severely shortened cycle life. This discrepancy with pressure was proven to be driven by stress distribution on cell components. The failure mechanisms and the effects of pressure fixture design on cell components were unveiled, shedding light on improving high-energy battery performance through at-scale fixture design.

25 - ENERGY STORAGE↗

From physics to fixtures to food: current and potential LED efficacy

Light-emitting diodes (LEDs) have enabled a historic increase in the conversion of electric energy to photons, but this is approaching a physical limit. The theoretical maximum efficiency occurs when all input energy is converted to energy in photosynthetic photons. Blue LEDs can be 93% efficient, phosphor-converted “whites” 76% efficient, and red LEDs 81% efficient. These improvements open new opportunities for horticultural lighting. Here we review (1) fundamental physics and efficiency of LEDs, (2) the current efficacy of LEDs, (3) the effect of spectral quality on crop yield, and (4) the potential efficacy of horticultural fixtures. Advances in the conversion of photons to yield can be achieved by optimization of spectral effects on plant morphology, which vary among species. Conversely, spectral effects on photosynthesis are remarkably similar across species, but the conventional definition of photosynthetic photons (400–700 nm) may need to be modified. The upper limit of LED fixture efficacy is determined by the LED package efficacy multiplied by four factors inherent to all fixtures: current droop, thermal droop, driver (power supply) inefficiencies, and optical losses. With current LED technology, the calculations indicate efficacy limits of 3.4 µmol J- 1 for white + red fixtures, and 4.1 µmol J -1 for blue + red fixtures. Adding optical protection from water and high humidity reduces these values by ~10%. We describe tradeoffs between peak efficacy and cost.

Agriculture↗

Particle Physics Division Lifting Fixture Database Restructure

The Particle Physics Division (PPD) at Fermilab needed to modernize its outdated lifting fixture database. Many fixtures lacked identification or had incomplete information. During a summer internship, I cross-referenced existing data, photographed and measured fixtures using standardized tools, and updated their locations and details in a modern Excel format. Some fixtures were identified as belonging to other departments, like the Applied Physics and Superconducting Technology Directorate (APS-TD). This effort significantly improved the accuracy and utility of the PPD database, streamlined other departmental inventories, and potentially saved hundreds of thousands of dollars. The work concluded with a clear, organized record of all verified lifting fixtures.

Creedon, Carroll [Unlisted, US, IL; Fermilab]↗

Design and Initial Verification Testing of an In Situ Load Retention Aging Fixture

Load retention is a key metric used to evaluate long-term mechanical functionality of polymeric materials. Its measurement currently requires periodically removing the aging fixtures from the ovens, removing the specimens from the fixtures, and performing load testing on the specimens. The ability to perform load measurement in situ (i.e., without having to remove the specimens from the fixtures, and possibly even the ovens) would facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of specimens which is more representative of the actual application.

36 MATERIALS SCIENCE↗

A simulation study of test fixture attachment points for vibration test optimization (MEEN 5440 Final Project)

The aerospace industry uses vibration shaker tables to perform component durability testing. These dynamic environments tests often have a hard time replicating the service environment of a component due to a mismatch in the applied force or the boundary condition. Figure 1 shows the desired outcome of a dynamic environments test. The measured responses in a lab test, ideally, should match the measured response of the service environment field test. One way to address the mismatch between field environment and lab environment is with test fixture design. The test fixture attaches the component under test to the shaker table. Single-axis shakers are the industry standard type of shaker table, and, therefore, test fixtures are often rigid in order to minimize cross-axis responses.

42 ENGINEERING↗

Optimization of an Impedance-Matched Test Fixture with the Modal Projection Error

Across many industries and engineering disciplines, components and systems are designed and deployed into their operational environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will function in its shock and vibration environments or if it will fail due to mechanical stresses. One method to determine if the component will survive the shock and vibration environments is to expose the component to the operational environment in a laboratory. One difficulty in executing a representative laboratory test is that the component may not have the same boundary condition in the laboratory as in the operational configuration. This paper examines the use of parameterized optimization to design the test fixture in order to better match the operational configuration. Several frequency and modal-based objective functions are examined for the optimization. The study shows that the Modal Projection Error objective function performs the best of the functions studied. The efficacy of the Modal Projection Error is demonstrated with respect to dynamic test fixture design on several analytical and experimental exemplars.

dynamic↗

Limited-constraint WAAM fixture for hybrid manufacturing

This paper describes a limited-constraint alternative to the traditional over-constrained build plate clamping in metal additive manufacturing. A fixture design is presented that enables build plate thermal growth within its plane while restricting deformation perpendicular to that plane. A prototype fixture is designed, fabricated, and tested for wire arc additive manufacturing (WAAM). Experimental results are presented for depositing 1.2 mm diameter 5356 aluminum wire on a 5052 aluminum build plate. The build plate deformation is measured for various clamping torques and a 77.3% reduction in distortion is achieved using the limited-constraint approach with identical WAAM parameters.

36 MATERIALS SCIENCE↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

Characterizing Dynamic Test Fixtures Through the Modal Projection Error

Across many industries and engineering disciplines, physical components and systems of components are designed and deployed into their environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will survive its physical environment or if it will fail due to mechanical stresses. One method to determine if the component will survive the environment is to expose the component to a simulation of the environment in a laboratory. One difficulty in doing this is that the component may not have the same boundary condition in the laboratory as is in the field configuration. This paper presents a novel method of quantifying the error in the modal domain that occurs from the impedance difference between the laboratory test fixture and the next level of assembly in the field configuration. The error is calculated from the projection from one mode shape space to the other, and the error is in terms of each mode of the field configuration. This provides insight into the effectiveness of the test fixture with respect to the ability to recreate the mode shapes of the field configuration. A case study is presented to show that the error in the modal projection between two configurations is a lower limit for the error that can be achieved by a laboratory test.

42 ENGINEERING↗