Search NASA⌕ Search

SEARCH · Search NASA

Results for “flexure mechanism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Large displacement behavior of double parallelogram flexure mechanisms with underconstraint eliminators

This paper presents a new analytical method for predicting the large displacement behavior of flexural double parallelogram (DP) bearings with underconstraint eliminator (UE) linkages. This closed-form perturbative Euler analysis method is able to – for the first time – directly incorporate the elastomechanics of a discrete UE linkage, which is a hybrid flexure element that is linked to ground as well as both stages on the bearing. The models are used to understand a nested linkage UE design, however the method is extensible to other UE linkages. Design rules and figures-of-merit are extracted from the analysis models, which provide powerful tools for accelerating the design process. The models, rules and figures-of-merit enable the rapid design of a UE for a desired large displacement behavior, as well as providing a means for determining the limits of UE and DP structures. This will aid in the adoption of UE linkages into DP bearings for precision mechanisms. Models are generated for a nested linkage UE design, and the performance of this DP with UE structure is compared to a DP-only bearing. As a result, the perturbative Euler analysis is shown to match existing theories for DP-only bearings with distributed compliance within ≈2%, and Finite Element Analysis for the DP with UE bearings within an average 10%.

42 ENGINEERING↗

Optomechanical Design of Compact Laminar Flexure Bending Mechanism for Elliptically Bent Hard X-ray Mirrors

As a part of the Argonne Strategic Partnership Project (SPP) 85E77, collaboration between Argonne National Laboratory (ANL) and Shanghai Institute of Applied Physics (SINAP), has produced designs for a precision compact flexure bending mechanism to provide elliptically shaped 90-mm and 160-mm long hard x-ray mirrors. The design utilizes Argonne's laminar nanopositioning flexure technique. The flexure mirror bending mechanism will be incorporated into the beamline upgrade project at the Shanghai Synchrotron Radiation Facility (SSRF). Additionally, an Argonne Laboratory-Directed Research and Development (LDRD) project at the Advanced Photon Source (APS) has adopted a modified optomechanical design of the precision compact mirror benders for 300-mm-long hard x-ray mirrors with integrated profile monitoring and feedback, which are described in this paper. The mirror benders are designed with configurations for open-loop or closed-loop controls. Capacitive sensors can be applied to the mirror benders to ensure positioning reproducibility. Design specifications as well as finite element analyses results of the compact mirror benders for hard x-ray mirrors with trapezoid and rectangular shapes are discussed in this paper.

X-ray optics, nanopositioning flexure stage↗

A Kinematic, Flexure-based Mechanism for Precise, Parallel Motion for the Hertz Variable-delay Polarization Modulator (VPM)

We describe the design of the linear motion stage for a Variable-delay Polarization Modulator (VPM) and of a grid flattener that has been built and integrated into the Hertz ground-based, submillimeter polarimeter. VPMs allow the modulation of a polarized source by controlling the phase difference between two linear, orthogonal polarizations. The size of the gap between a mirror and a very flat polarizing grid determines the amount of the phase difference. This gap must be parallel to better than 1% of the wavelength. A novel, kinematic, flexure-based mechanism is described that passively maintains the parallelism of the mirror and the grid to 1.5 pm over a 150 mm diameter, with a 400 pm throw. A single piezoceramic actuator is used to modulate the gap, and a capacitive sensor provides position feedback for closed-loop control. A simple device that ensures the planarity of the polarizing grid is also described. Engineering results from the deployment of this device in the Hertz instrument April 2006 at the Submillimeter Telescope Observatory (SMTO) in Arizona are presented.

Voellmer, G. M.↗

A Flexure-Based Mechanism for Precision Adjustment of National Ignition Facility Target Shrouds in Three Rotational Degrees of Freedom

This study presents the design of a flexure-based mount allowing adjustment in three rotational degrees of freedom (DOFs) through high-precision set-screw actuators. The requirements of the application called for small but controlled angular adjustments for mounting a cantilevered beam. The proposed design is based on an array of parallel beams to provide sufficiently high stiffness in the translational directions while allowing angular adjustment through the actuators. A simplified physical model in combination with standard beam theory was applied to estimate the deflection profile and maximum stresses in the beams. A finite element model was built to calculate the stresses and beam profiles for scenarios in which the flexure is simultaneously actuated in more than one DOF.

3 DOF↗

Compliance and control characteristics of an additive manufactured-flexure stage

This paper presents a compliance and positioning control characteristics of additive manufactured-nanopositioning system consisted of the flexure mechanism and voice coil motor (VCM). The double compound notch type flexure stage was designed to utilize the elastic deformation of two symmetrical four-bar mechanisms to provide a millimeter-level working range. Additive manufacturing (AM) process, stereolithography, was used to fabricate the flexure stage. The AM stage was inspected by using 3D X-ray computerized tomography scanner: air-voids and shape irregularity. The compliance, open-loop resonance peak, and damping ratio of the AM stage were measured 0.317 mm/N, 80 Hz, and 0.19, respectively. The AM stage was proportional-integral-derivative positioning feedback-controlled and the capacitive type sensor was used to measure the displacement. As a result, the AM flexure mechanism was successfully 25 nm positioning controlled within 500 μm range. The resonance peak was found approximately at 280 Hz in closed-loop. This research showed that the AM flexure mechanism and the VCM can provide millimeter range with high precision and can be a good alternative to an expensive metal-based flexure mechanism and piezoelectric transducer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Carbon Fiber Surface Modification on the Mechanical Properties of Carbon-Fiber-Reinforced Ultrahigh-Molecular-Weight Polyethylene Composite

In this paper, the surface properties and morphologies of the concentrated nitric acid (HNO{sub 3})-modified carbon fiber (CF) were characterized by XPS, SEM, and contact angle goniometer, respectively. The results showed that both the oxygen-containing functional groups content and the surface roughness of concentrated HNO{sub 3}-modified CF significantly increased. The contact angle of concentrated HNO{sub 3}-modified CF was obviously lower than that of unmodified CF. Studies on the mechanical properties of carbon-fiber-reinforced ultrahigh-molecular-weight polyethylene (CF/UHMWPE) composite revealed that the stress–strain behavior gradually changed from nonlinear to linear relationship with the rise of CF content in UHMWPE matrix. Both the tensile strength and modulus increased with the rise of CF content. Conversely, as the CF content in UHMWPE matrix is increasing, the flexural strength and modulus increased first and then decreased. The flexural strength and modulus of CF/UHMWPE composite with 30 wt.% CF content reached the maximum value of 157.61 MPa and 9.82 GPa, respectively. Moreover, the CF surface modification and CF content have a synergistic effect on the tensile and flexural mechanical properties of the CF/UHMWPE composite. The influence of CF modification on the tensile and flexural mechanical properties of the composite became more and more obvious with the rise of CF content.

36 MATERIALS SCIENCE↗

Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

47 OTHER INSTRUMENTATION↗

The Palomar Adaptive Optics System

Currently under construction at the Jet Propulsion laboratory, the Palomar Adaptive Optics System (PALAO) is a Cassegrain-mounted system for infrared astronomy incorporating active laser metrology to minimize the effects of mechanical flexure.

Palomar Adaptive Optics System palomar optics PALA↗

The Analysis of Results from 3-Point Flexure Testing of Irradiated AGC-1 Graphite Creep Specimens

Here we report the analysis of test data from AGC-1 specimen 3-pt flexure testing. At this time all mechanical (flexural) testing of AGC-1 specimens has been completed. Individual force-extension curves are available as .txt files recorded electronically from the author (burchelltd@ornl.gov). This Technical Memorandum meets Idaho National Laboratories statement of Work No. 10752 Rev. 3 deliverable 4.4C “Issue a draft ORNL TM report summarizing the results and data analysis of all mechanical testing to INL no later than May 15, 2015.” The data and analysis was provided in a timely fashion as an excel s/s with data analysis plots. This TM follows on and formalizes transmission of the data. The major conclusion from this analysis is that there is no additional effect of creep strain on the flexure strength of graphite.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Results of 3-Point Flexure Testing of Irradiated AGC-1 Graphites Specimens

Here we report the test data from AGC-1 specimen 3-pt flexure testing. At this time all mechanical (flexural) testing of AGC-1 specimens has been completed. Individual force-extension curves are available as .txt files recorded electronically and are available from the author (burchelltd@ornl.gov). Typical curves are included for both the unirradiated and irradiated specimens. The flexure strength has been calculated for each specimen. This letter report meets Idaho National Laboratories statement on Work No. 10752 Rev. 3 deliverable 4.4B “Issue an electronic letter report communication indicating the status of AGC-1 mechanical testing to INL no later than March 27, 2015."

36 MATERIALS SCIENCE↗

Bulk Metallic Glasses and Composites for Optical and Compliant Mechanisms

Mechanisms are used widely in engineering applications due to their ability to translate force and movement. They are found in kinematic pairs, gears, cams, linkages, and in flexure mechanisms (also known as compliant mechanisms). Mechanisms and flexures are used widely in spacecraft design, especially in the area of optics, where precise positioning of telescope mirrors requires elastic flexing of elements. A compliant mechanism is generally defined as a flexible mechanism that uses an elastic body deformation to cause a displacement (such as positing a mirror). The mechanisms are usually constructed as a single monolithic piece of material, and contain thin struts to allow for large elastic bending with low input force. This creates the largest problem with developing precise mechanisms; they must be fabricated from a single piece of metal, but are required to have strict accuracy on their dimensions. They are generally required to have high strength, elasticity, and low coefficient of thermal expansion.

Hofmann, Douglas C.↗

Signal propagation in reversible digital mechanics

Digital mechanics explores information processing through binary, mechanical circuits. This work demonstrates a flexural, mechanical integrated circuit (m-IC) that achieves reversible, non-reciprocal signal propagation through integrated AND logic and memory. Our approach exploits sequential bistable transitions with symmetric energy wells, tunable stiffness, impedance matching, and AND gate non-linearity, to enable signal propagation, repeatability, and reversibility. We present a generalized model of logic kinematics and energetics, validated experimentally, to study energy flows, quantify energetic limits, and identify operating regimes for reversible logic. Macro-scale experiments confirm propagation dynamics, and new fabrication methods extend the architecture to micro-scale devices. By achieving controlled, reversible signal transmission across interconnected logic and memory, this work establishes a scalable platform for robust mechanical computing and adaptive sensing.

Johnson, Hilary A. [Lawrence Livermore National La↗

COMPARISON OF ELASTIC OF POROUS CORDIERITE BY FLEXURE AND DYNAMIC TEST METHODS

Previous work showed differences in apparent elastic modulus between mechanical flexure testing and resonance methods. Flexure tests have been conducted using non-contact optical systems to directly measure deflection for calculation of elastic modulus. Dynamic test methods for elastic modulus measurement were conducted on the same material for comparison. The results show significant difference in the apparent elastic modulus for static flexure versus dynamic methods. The significance of the difference in apparent elastic modulus on thermal stress and the hypotheses for these differences will be discussed. Dynamic measurement (resonance) and static measurement (mechanical) produce different values for elastic modulus of porous cordierite ceramic. The elastic modulus from resonance is a measure of the material response at very low strain which is different from the material response in a mechanical test with relatively large strain. The apparent elastic moduli for dynamic versus static test methods in this study are different by a factor of two. This result has significant impact on calculated stress and life in an aftertreatment component.

36 MATERIALS SCIENCE↗

Research on graphite reinforced glass matrix composites

A broad group of fibers and matrices were combined to create a wide range of composite properties. Primary material fabrication procedures were developed which readily permit the fabrication of flat plate and shaped composites. Composite mechanical properties were measured under a wide range of test conditions. Tensile, flexure mechanical fatigue, thermal fatigue, fracture toughness, and fatigue crack growth resistance were evaluated. Selected fiber-matrix combinations were shown to maintain their strength at up to 1300 K when tested in an inert atmosphere. Composite high temperature mechanical properties were shown to be limited primarily by the oxidation resistance of the graphite fibers. Composite thermal dimensional stability was measured and found to be excellent.

Prewo, K. M.↗

Mechanisms for Engineering Design.

Book on functional mechanisms for engineering design, presenting kinematic characteristics of output motion, planar linkage and spatial cycloidal crank and flexural mechanisms

KINEMATICS↗

Enhancing the Mechanical Toughness of Epoxy-Resin Composites Using Natural Silk Reinforcements

Strong and tough epoxy composites are developed using a less-studied fibre reinforcement, that of natural silk. Two common but structurally distinct silks from the domestic B. mori/Bm and the wild A. pernyi/Ap silkworms are selected in fabric forms. We show that the toughening effects on silk-epoxy composites or SFRPs are dependent on the silk species and the volume fraction of silk. Both silks enhance the room-temperature tensile and flexural mechanical properties of the composite, whereas the more resilient Ap silk shows a more pronounced toughening effect and a lower critical reinforcement volume for the brittle-ductile transition. Specifically, our 60 vol.% Ap-SFRP displays a three-fold elevation in tensile and flexural strength, as compared to pure epoxy resin, with an order of magnitude higher breaking energy via a distinct, ductile failure mode. Importantly, the 60 vol.% Ap-SFRP remains ductile with 7% flexural elongation at lower temperatures (-50 °C). Under impact, these SFRPs show significantly improved energy absorption, and the 60 vol.% Ap-SFRP has an impact strength some eight times that of pure epoxy resin. Lastly, the findings demonstrate both marked toughening and strengthening effects for epoxy composites from natural silk reinforcements, which presents opportunities for mechanically superior and "green" structural composites.

36 MATERIALS SCIENCE↗

Note: Decoupling design for high frequency piezoelectric ultrasonic transducers with their clamping connections

This work presents the flexure-mechanism based decoupling design between high frequency piezoelectric ultrasonic transducers and their clamping connections to improve ultrasonic energy transmission efficiency. The ring, prismatic beam, and circular notched hinge based flanges were presented, and the crucial geometric dimensions of the transducers with the flexure decoupling flanges were determined. Finite element analysis (FEA) was carried out to investigate the dynamic characteristics of the transducers. Finally, experiments were conducted to examine and verify the effects of the proposed decoupling flanges. FEA and experimental results show that smaller frequency deviations and larger tip displacement amplitudes have been achieved by using the transducers with the flexure flanges compared with the transducer with a rigid ring-type flange, and thus the ultrasonic transmission efficiency can be improved through the flexure flanges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗