Search NASA⌕ Search

SEARCH · Search NASA

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Throughfall-Reduction Drying Effects on Forest Floor Plant Tissue Biomass (Oi+Oe soil horizons) and Moisture Content in Four Lowland Panamanian Forests

Objectives: Climatic drying is predicted for many tropical forests, yet effects on soil properties across moisture and soil gradients within tropical forests remain poorly characterized, hampering predictions of forest-climate feedbacks. We hypothesized that drying would suppress soil CO2 fluxes (i.e., respiration) in already-drier tropical forests by further reductions in soil moisture, but increases CO2 fluxes in wetter tropical forests by alleviating anaerobiosis and soil saturation. We measured soil CO2 fluxes, soil moisture, soil temperature, and forest floor biomass during wet-dry cycles (2015 – 2022) in four Panamanian forests that vary in rainfall and soil fertility. We also surveyed all tree species and identified to species in 2018 and 2019.Results: We found that soil moisture peaked in the wet season and declined in the dry season. Measured soil CO2 fluxes declined in the dry season and peaked in the early wet season ahead of peak soil moisture, resulting in a lower soil moisture optimum for respiration than previously modeled. Forest floor biomass peaked in the dry season, in contrast. Chronic throughfall exclusion also suppressed soil moisture across the four forests to 20cm depths, and also initially suppressed soil CO2 fluxes across forests. There was sustained suppression of soil CO2 fluxes after four years in the wettest forest only (-28 ± 4% during the dry season), but elevated soil CO2 fluxes in a fertile forest after four years (+75 ± 28% during the late wet season). The unexpected negative drying effect in the wettest, most infertile forest could have resulted from reduced vertical flushing of nutrients into soils, as the drying effect increased with time. Including hydro-nutrient interactions in ecosystem models could improve predictions of tropical forest-climate feedbacks (results presented in Cusack et al. 2023). Datasets included: Datasets included here include .csv and .xls files for forest floor biomass (equivalent to the Oi+Oe soil horizons), and a subset include forest floor biomass moisture content (weight/weight) in the study plots. There is also a .kml file that includes coordinates for all 32 plots included in the study of four forests (n = 4 throughfall reduction and n = 4 control plots per site). No special software is needed to open these files.

54 ENVIRONMENTAL SCIENCES↗

Salt Tank Testbed: a Test Site Designed to Replicate Floor Buckles Observed in Commercial TES Tanks

A test site has been designed and is under construction to replicate the buckling failure ob-served in several in-service storage tanks for nitrate salts operating up to 565°C. In commercial tanks multiple factors have been identified that influence the floors susceptibility to buck-ling, including: the as-manufactured shape of the floor, high compressive stresses due to thermal gradients and/or friction, fluid inventory and absolute temperature. Based on exten-sive modeling analysis it was determined that similar buckles can be reproduced in a scaled test tank (approximately 9x smaller than a representative commercial tank design). To buckle the scaled tank a radial thermal gradient is generated in the tank with a low fluid level, the fluid level is then increased while maintaining the thermal gradient; based on the modeling results just one of these cycles can plastically deform the tank floor. The test site which is under construction is designed to replicate this damaging cycle at lower temperatures. The goal of testing will be to reproduce this damaging cycle and buckle the scaled test tank floor, allowing proper model validation and a methodology for comparing different tank designs at a smaller (and less costly) scale.

25 ENERGY STORAGE↗

RapidClave Technology Demonstrations-II Kevlar Composite Vehicle Floor

This Demonstration’s objective was to develop enhanced methods to produce a complex preform comprised of Kevlar fabric and thermoplastic adhesive and rapidly consolidate the preform into the desired functional shape of a vehicular floor protection system. The approach and outcome goals were to reduce the tooling cost by 50% and shorten the processing time by 50% using the RapidClave® to consolidate the part rather than an autoclave. UDRI partnered with O’Gara Armoring who currently produces one piece Kevlar floor composite laminates that offer enhanced impact resistance at lighter weights as compared to steel. These laminates are constructed by hand layup of 3000 denier K29 fiber in a plain weave architecture with a thermoplastic film adhesive layer manufactured by Barrday and will be referred to as semi-preg throughout this paper. The current process is labor intensive and costly. Current production rates are only about one per month but an improved process is expected to enable product growth. A 50% reduction in tooling cost was achieved through the use of additive tooling, and the RapidClave® process enabled a 60% reduction in cycle time. Further cost savings were realized through the implementation of a preforming process that resulted in a 65% reduction in labor hours. This new approach for manufacturing reinforced vehicle floors has been partially implemented by O’Gara with plans to continue work on additional vehicle models. The cost savings has potential for increasing O’Gara’s production to reach new markets, and lead to job creation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗

ResStock Measure Documentation: Attic Floor Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Attic Floor Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Floor and ceiling effects in the EORTC QLQ-C30 Physical Functioning subscale among patients with advanced or metastatic breast cancer

The European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire Core 30 Physical Functioning subscale is a widely used patient-reported outcome measure that quantifies cancer patients' physical functioning. Strong floor/ceiling effects can affect a scale's sensitivity to change. The aim of this study was to characterize floor/ceiling effects of the physical functioning domain in patients with advanced/metastatic breast cancer enrolled in commercial clinical trials and a community-based trial. The clinical trial cohort comprised patients from 5 registrational trials submitted to the Food and Drug Administration for review (2010-2017). The community cohort comprised a subgroup of patients from the Alliance Patient Reported Outcomes to Enhance Cancer Treatment (PRO-TECT) trial. The distribution of patient responses to Physical Functioning items and the summed score were assessed at the baseline and 3-month follow-up for both cohorts. Descriptive statistics were used to determine floor/ceiling effects at the item and scale levels. The clinical trial cohort and the community cohort consisted of 2407 and 178 patients, respectively. Twenty-four percent or more of the respondents reported “not at all” for having trouble/needing help with each Physical Functioning item across both cohorts and measurement time points. Fourteen to twenty percent of the patients scored perfectly (100 of 100) on the Physical Functioning subscale summary measure (where higher scores indicated better physical functioning) across both cohorts and time points. Minor floor effects and notable ceiling effects were found at the item and scale levels of the Physical Functioning subscale, regardless of cohort, and this creates some uncertainty about its ability to detect changes in physical functioning among high-functioning patients. In conclusion, investigators may consider adding additional high-functioning items from the EORTC's item library to more accurately describe the impact of anticancer treatment on patients' physical functioning.

60 APPLIED LIFE SCIENCES↗

Servomotor-driven leveling elements for machine tool frame-to-floor alignment

This paper presents the results of aligning the frame to concrete floor of a large 5-axis machine tool by leveling element adjustments using servomotors instead of manual operation. The machine tool leveling elements used in this study are mechanical devices that attach the machine tool frame to the concrete foundation. These leveling elements are also adjustable so that each location along the machine tool can be uniquely adjusted such that the geometric errors of the frame are minimized, and the accuracy of the machine tool is improved. Off-the-shelf servomotors and connection equipment were installed at each of 12 leveling element locations for a precision 5-axis machine tool at Oak Ridge National Laboratory. The servomotors allow a technician to align the machine tool frame remotely, instead of crawling under the machine tool to iteratively manually adjust each of the 12 leveling elements. The open-loop servomotor-leveling element system design is presented in this paper as well as machine tool frame alignment results. The servomotor system significantly reduces leveling element adjustment time, eliminates the need for under-machine access, reduces technician physical strain, and significantly improves the adjustment repeatability.

Honeycutt, Andrew [ORNL]↗

Portable Tank Storage Pit Technical Documents and Associated Flooring Documents

The work performed under this section includes the surface preparation and application of protective floor coatings; furnishing all labor, materials, and equipment necessary to perform all operations in connection with the application required for satisfactory completion in accordance with the standards and practices set forth herein.

99 GENERAL AND MISCELLANEOUS↗

Impact of intense sanitization procedures on bacterial communities recovered from floor drains in pork processing plants

Pork processing plants in the United States (US) cease operations for 24–48 h every six or twelve months to perform intense sanitization (IS) using fogging, foaming, and further antimicrobial treatments to disrupt natural biofilms that may harbor pathogens and spoilage organisms. The impact such treatments have on short-term changes in environmental microorganisms is not well understood, nor is the rate at which bacterial communities return. Swab samples were collected from floor drains to provide representative environmental microorganisms at two US pork processing plants before, during, and after an IS procedure. Samples were collected from four coolers where finished carcasses were chilled and from four locations near cutting tables. Each sample was characterized by total mesophile count (TMC), total psychrophile count (TPC), and other indicator bacteria; their biofilm-forming ability, tolerance of the formed biofilm to a quaternary ammonium compound (300 ppm, QAC), and ability to protect co-inoculated Salmonella enterica. In addition, bacterial community composition was determined using shotgun metagenomic sequencing. IS procedures disrupted bacteria present but to different extents depending on the plant and the area of the plant. IS reduced TPC and TMC, by up to 1.5 Log 10 CFU only to return to pre-IS levels within 2–3 days. The impact of IS on microorganisms in coolers was varied, with reductions of 2–4 Log 10 , and required 2 to 4 weeks to return to pre-IS levels. The results near fabrication lines were mixed, with little to no significant changes at one plant, while at the other, two processing lines showed 4 to 6 Log 10 reductions. Resistance to QAC and the protection of Salmonella by the biofilms varied between plants and between areas of the plants as well. Community profiling of bacteria at the genus level showed that IS reduced species diversity and the disruption led to new community compositions that in some cases did not return to the pre-IS state even after 15 to 16 weeks. The results found here reveal the impact of using IS to disrupt the presence of pathogen or spoilage microorganisms in US pork processing facilities may not have the intended effect.

59 BASIC BIOLOGICAL SCIENCES↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors’ subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 11) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

47 OTHER INSTRUMENTATION↗

A neutrino floor for the Migdal effect

Neutrino-nucleus scatterings in the detector could induce electron ionization signatures due to the Migdal effect. We derive prospects for a future detection of the Migdal effect via coherent elastic solar neutrino-nucleus scatterings in liquid xenon detectors, and discuss the irreducible background that it constitutes for the Migdal effect caused by light dark matter-nucleus scatterings. Furthermore, we explore the ionization signal induced by some neutrino electromagnetic and non-standard interactions on nuclei. In certain scenarios, we find a distinct peak on the ionization spectrum of xenon around 0.1 keV, in clear contrast to the Standard Model expectation.

Experimental Nuclear Physics↗