Performance of Compressor of XJ-41-V Turbojet Engine VI - Analysis of Compressor Flow Choking: Analysis of Compressor Flow Choking - 6

An extended analysis was made of the previously reported performance investigation of the original compressor from the XJ-41-v turbojet engine and a similar compressor revised a to obtain a 33-percent increase in the geometric passage area at the vaned-collector entrance. This analysis was based on the concept of the vaned-collector entrance as the throat section of a nozzle. Because of nonuniform air distribution at the vaned-collector entrance, approximately 90 percent of the available flow area was utilized in the original compressor and 94percent in the revised com$ressor. The increase in maximum weight flow obtained with the revised compressor was disproportionate to the increased effective critical throat area because. the air density at the revised vaned-collector entrance for maximum flow was lower than that obtained in the original compressor. This reduction in density resulted from the large pressure losses near the impeller inlet of the revised compressor, which is indicative of impending flow choking in the impeller, The.calculated maximum corrected weight-flow capacity of a compressor consisting of the revised vaneless diffuser and vaned collector with a theoretical impeller that combined peak impeller pressure ratio and peak impeller efficiency at the . maximum flow point would be 112 pounds per second for an equivalent impeller speed of 11,500 rpm;

Creagh, John W. R.↗

Meanline Analysis of Turbines with Choked Flow in the Object-Oriented Turbomachinery Analysis Code

The prediction of turbomachinery performance characteristics is an important part of the conceptual aircraft engine design process. During this phase, the designer must examine the effects of a large number of turbomachinery design parameters to determine their impact on overall engine performance and weight. The lack of detailed design information available in this phase necessitates the use of simpler meanline and streamline methods to determine the turbomachinery geometry characteristics and provide performance estimates prior to more detailed CFD (Computational Fluid Dynamics) analyses. While a number of analysis codes have been developed for this purpose, most are written in outdated software languages and may be difficult or impossible to apply to new, unconventional designs. The Object-Oriented Turbomachinery Analysis Code (OTAC) is currently being developed at NASA Glenn Research Center to provide a flexible meanline and streamline analysis capability in a modern object-oriented language. During the development and validation of OTAC, a limitation was identified in the code's ability to analyze and converge turbines as the flow approached choking. This paper describes a series of changes which can be made to typical OTAC turbine meanline models to enable the assessment of choked flow up to limit load conditions. Results produced with this revised model setup are provided in the form of turbine performance maps and are compared to published maps.

Choked Flow↗

Toward the use of similarity theory in two-phase choked flows

Comparison of two phase choked flows in normalized coordinates were made between pure components and available data using a reference fluid to compute the thermophysical properties. The results are favorable. Solution of the governing equations for two LNG mixtures show some possible similarities between the normalized choked flows of the two mixtures, but the departures from the pure component loci are significant.

Hendericks, R. C.↗

A visual study of radial inward choked flow of liquid nitrogen

A visual study of the radial inward choked flow of liquid nitrogen was conducted. Data and high speed moving pictures were obtained. The study indicated the following: (1) steady radial inward choked flow seems equivalent to steady choked flow through axisymmetric nozzles, (2) transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets, and (3) the critical mass flow rate data for the transient case appear different from those of the steady case.

Hendricks, R. C.↗

Pressure distribution in a converging-diverging nozzle during two-phase choked flow of subcooled nitrogen

Choked flow rates and axial pressure distributions were measured for subcooled nitrogen in a converging-diverging nozzle with a constant area section in the throat region. Stagnation pressures ranged from slightly above saturation to twice the thermodynamic critical pressure. Stagnation temperatures ranged from 0.75 to 1.03 times the thermodynamic critical temperature. The choking plane appears to be at the divergence end of the constant area throat section. At high stagnation pressures the fluid appears to stay liquid well into the constant area throat region; however, at near saturation stagnation pressures it appears that vaporization occurs at or before the entrance to the constant area throat region. The throat-to-stagnation pressure ratio data exhibits an anomalous flat region. This anomaly appears to be fundamentally related to the two-phase process and not merely to the present specific nozzle geometry. The fluid appears to be metastably all liquid below the saturation pressure. The data are compared to various flow models. No model adequately describes the whole range of the experiment.

Simoneau, R. J.↗

Pressure distribution in a converging-diverging nozzle during two-phase choked flow of subcooled nitrogen

Choked flow rates and axial pressure distributions were measured for subcooled nitrogen in a converging-diverging nozzle with a constant area section in the throat region. Stagnation pressures ranged from slightly above saturation to twice the thermodynamic critical pressure. Stagnation temperatures ranged from 0.75 to 1.03 times the thermodynamic critical temperature. The choking plane is at the divergence end of the constant area throat section. At high stagnation pressures the fluid stays liquid well into the constant area throat region; at near saturation stagnation pressures it appears that vaporization occurs at or before the entrance to the constant area throat region. The throat-to-stagnation pressure ratio data exhibits an anomalous flat region, and this anomaly is related to the two-phase process. The fluid is metastably all liquid below the saturation pressure.

Simoneau, R. J.↗

Toward the use of similarity theory in two-phase choked flows

Comparison of two-phase choked flows in normalized coordinates were made between pure components and available data using a reference fluid to compute the thermophysical properties. The results are favorable. Solution of the governing equations for two LNG mixtures show some possible similarities between the normalized choked flows of the two mixtures, but the departures from the pure component locii are significant.

Hendricks, R. C.↗

A visual study of radial inward choked flow of liquid nitrogen.

Data and high speed movies were acquired on pressurized subcooled liquid nitrogen flowing radially inward through a 0.0076 cm gap. The stagnation pressure ranged from 0.7 to 4 MN/sq m. Steady radial inward choked flow appears equivalent to steady choked flow through axisymmetric nozzles. Transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets. The critical mass flow rate data for the transient case appear different from those for the steady case. On the mass flow rate vs pressure map, the slope and separation of the isotherms appear to be less for transient than for steady radial choked flow.

Hendricks, R. C.↗

Two-phase choked flow of cryogenic fluids in converging-diverging nozzles

Data are presented for the two phase choked flow of three cryogenic fluids - nitrogen, methane, and hydrogen - in four converging-diverging nozzles. The data cover a range of inlet stagnation conditions, all single phase, from well below to well above the thermodynamic critical conditions. In almost all cases the nozzle throat conditions were two phase. The results indicate that the choked flow rates were not very sensitive to nozzle geometry. However, the axial pressure profiles, especially the throat pressure and the point of vaporization, were very sensitive to both nozzle geometry and operating conditions. A modified Henry-Fauske model correlated all the choked flow rate data to within + or - 10 percent. Neither the equilibrium model nor the Henry-Fauske model predicted throat pressures well over the whole range of data. Above the thermodynamic critical temperature the homogeneous equilibrium model was preferred for both flow rate and pressure ratio. The data of the three fluids could be normalized by the principle of corresponding states.

Simoneau, R. J.↗

Two-phase choked flow of subcooled nitrogen through a slit

Two-phase choked flow rate and pressure distribution data are reported for subcooled nitrogen flowing through a slit. The slip was a narrow rectangular passage of equal length and width. The inlet stagnation pressure ranged from slightly above saturation to twice the thermodynamic critical pressure. Four stagnation isotherms were investigated covering a range which spanned the critical temperature. The results suggested a uniform two-phase flow pattern with vaporization occurring at or near the exit in most cases. The results compared favorably with the theory of Henry for nonequilibrium subcooled two-phase choked flow in long tubes.

Simoneau, R. J.↗

Two-phase choked flow of subcooled nitrogen through a slit

Two-phase choked flow rate and pressure distribution data are reported for subcooled nitrogen flowing through a slit. The slit was a narrow rectangular passage of equal length and width. The inlet stagnation pressure ranged from slightly above saturation to twice the thermodynamic critical pressure. Four stagnation isotherms were investigated, covering a range which spanned the critical temperature. The results suggested a uniform two-phase flow pattern with vaporization occurring at or near the exit in most cases. The results compared favorably with the theory of Henry (1970) for nonequilibrium subcooled two-phase choked flow in long tubes.

Simoneau, R. J.↗

Two phase choke flow in tubes with very large L/D

Two phase and gaseous choked flow data for fluid nitrogen were obtained for a test section which was a long constant area duct of 16 200 L/D with a diverging diffuser attached to the exit. Flow rate data were taken along five isotherms (reduced temperature of 0.81, 0.96, 1.06, 1.12, and 2.34) for reduced pressures to 3. The flow rate data were mapped in the usual manner using stagnation conditions at the inlet mixing chamber upstream of the entrance length. The results are predictable by a two-phase homogeneous equilibrium choking flow model which includes wall fraction. A simplified theory which in essence decouples the long tube region from the high acceleration choking region also appears to predict the data reasonably well, but about 15 percent low.

Hendricks, R. C.↗

Aerodynamic and Acoustic Performance of Two Choked-Flow Inlets Under Static Conditions

Tests were conducted to determine the aerodynamic and acoustic performance of two choking flow inlets under static conditions. One inlet choked the flow in the cowl throat by an axial translation of the inlet centerbody. The other inlet employed a translating grid of airfoils to choke the flow. Both inlets were sized to fit a 13.97 cm diameter fan with a design weight flow of 2.49 kg/sec. The inlets were operated in both the choked and unchoked modes over a range of weight flows. Measurements were made of inlet pressure recovery, flow distortion, surface static pressure distribution, and fan noise suppression. Choking of the translating centerbody inlet reduced blade passing frequency noise by 29 db while yielding a total pressure recovery of 0.985. Noise reductions were also measured at 1/3-octave band center frequencies of 2500, 5000, and 20,000 cycles. The translating grid inlet gave a total pressure recovery of 0.968 when operating close to the choking weight flow. However, an intermittent high intensity noise source was encountered with this inlet that precluded an accurate measurement of inlet noise suppression.

Miller, B. A.↗

Two phase choke flow in tubes with very large L/D

Data were obtained for two phase and gaseous choked flow nitrogen in a long constant area duct of 16200 L/D with a diverging diffuser attached to the exit. Flow rate data were taken along five isotherms (reduced temperature of 0.81, 0.96, 1.06, 1.12, and 2.34) for reduced pressures to 3. The flow rate data were mapped in the usual manner using stagnation conditions at the inlet mixing chamber upstream of the entrance length. The results are predictable by a two phase homogeneous equilibrium choking flow model which includes wall friction. A simplified theory which in essence decouples the long tube region from the high acceleration choking region also appears to predict the data resonably well, but about 15 percent low.

Hendricks, R. C.↗

Meanline Analysis of Turbines with Choked Flow in the Object-Oriented Turbomachinery Analysis Code

The Object-Oriented Turbomachinery Analysis Code (OTAC) is a new meanline/streamline turbomachinery modeling tool being developed at NASA GRC. During the development process, a limitation of the code was discovered in relation to the analysis of choked flow in axial turbines. This paper describes the relevant physics for choked flow as well as the changes made to OTAC to enable analysis in this flow regime.

Turbomachinery↗

One-dimensional analysis of choked-flow turbines

Flow conditions internal to choked-flow turbines were subjected to a one-dimensional analysis. Factors affecting the design, operation, and manufacture of such turbines were investigated. Criteria are presented which will aid in analysis of test data from such turbines. The effect of turbine-stator adjustment on internal flow conditions was investigated for one application of turbine stator adjustment.

TURBINES - AXIAL FLOW↗